EVIL®MINION™BOARD
SETTINGS + FUNCTIONS
When servicing the EVIL®MINION™:
• Make sure a barrel sleeve is fitted
to the EVIL
®
MINION™.
• Make sure your hopper is removed
from the EVIL®MINION™.
• Make sure there are no paintballs in the
breech of the EVIL®MINION™.
• Always remove the first stage regulator
and relieve all residual gas pressure from
the EVIL
®
MINION™before disassembly.
• The EVIL®MINION™can hold a small residual
charge of gas, typically 1 shot, with the
first stage regulator removed. Always
discharge the marker in a safe direction to
relieve this residual gas pressure.
WARNING
BUTTONS AND LED INDICATOR
There are two buttons and a LED indicator mounted inside the EVIL®MINION™frame. These are
accessible on the back side of the frame. The top button is used to turn the EVIL®MINION™ON and
OFF. The bottom button is used to turn the eye feature of the EVIL
®
MINION™ON and OFF.
To turn the EVIL®MINION™ON press and hold the top button until the LED indicates orange and
changes to either red or green, the MINION is ready to fire. If there is no ball and the LED is RED, you
hold the trigger for 1 second to force the MINION to fire once. If there is a paintball inside the breech
and the LED is green, just press the trigger to fire the marker.
In normal operation mode the LED indicator provides the following information:
Orange Bootup sequence.
Red No ball detected inside the EVIL®MINION™(eyes ON).
Green Ball detected inside the EVIL®MINION™(eyes ON).
Blinking Red Eye function turned OFF. The EVIL®MINION™will fire even though
there is no ball inside the breech.
Blinking Green Eyes are blocked. Either the eyes are either dirty, the marker is not
gassed up, there is a bad connection between the board and the eyes
or the battery is low.
BOARD SETTINGS AND CONFIGURATION MODE
There are five settings you can alter on the EVIL®MINION™board. (see figure 2):
1. ABS (Anti Bolt Stick)
This helps to prevent bolt-stick, but may result in higher velocity for the first shot.
2. Trigger Sensitivity Adjusts the delay between two trigger pulls.
3. Dwell Time the solenoid is activated for.
4. ROF (Rate of Fire) when the eye is deactivated.
5. Fire Mode
Setting 1, Anti Bolt Stick, is changed by turning DIP switch #1 on the circuit board either ON or OFF.
When ABS is activated, the dwell is increased after 15 seconds of non-use for the next shot fired. This
helps prevent bolt stick. Factory default is ON. Notice that the setting is only activated after re-starting
the EVIL
®
MINION™.
The following settings 2-5 can only be modified in configuration mode. To activate the configuration
mode, turn your marker off, unscrew the two left side grip panel screws with a 3/32” allen key and set
DIP switch #2 to the on position. Next, turn your marker on. The 3-color LED will cycle through all
colors for one second to indicate that you have entered the configuration mode. To cycle through
different settings, pull and release the trigger. Configuration mode has 4 settings that can be changed.
NOTE: The eye is always activated when you turn the marker on, to turn off the eye feature press and
hold the bottom button until the LED starts blinking Red.
NOTE: The EVIL®MINION™automatically switches off after 10 minutes of non-use.
ORANGE
GREEN
RED
Figure 1
www.evil-paintball.com
4