Everspring Industry Co SR102 Users Manual

SR102 REMOTE TRANSMITTER
d
The Remote Transmitter is designed to control a series of O-net products, such as EZ Alarm (SE131), On/Off Receiver (AN121, B410N) and Dimmer Receiver (AD121, B410D), serving as a multipurpose remote controller. It is equipped with 7 sets of ID codes, therefore, each set of them is capable of controlling limitless receivers.
LOADING THE BATTERY
1. Remove the battery cover. Fit the 3V Lithium battery in the compartment provided with +v terminal facing upwardly . (Fig. 1)
Fig. 1
2. By pressing any key, the red LED will illuminate, which implies that the battery has been inserted properly.
3. Replace the battery cover.
SETTING THE HOUSE CODE
The Transmitter incorporates 4 buttons and a 4-position house code slide switch. The 4-position house code slide switch ranges from A to D. (Fig. 2) When controlling EZ alarm (SE131), the house code slide switch has to be set in “A” position, while “B”, “C” and “D” positions are designed for use with On/Off Receiver (AN121, B410N), Dimmer Receiver (AD121, B410D), Lantern Receiver (ED102) and forthcoming O-net series products.
4-position house code slide switch coupled with 4 buttons may formulate 7 sets of
ID codes, every of which is controllable to numerous receivers.
1. Setting the house code slide switch to “A” can operate EZ alarm (SE131).
House Code Position “A”
Button No. of ID ID1 ID1 ID1 ID1
When switching to the “A” position which is situated in the orange background of plate, simply follow its orange track for operating (instant arm), (delay arm), (chime) and (disarm) modes.
2. Setting the house code slide switch to “B”, “C” or “D” position can take control of On/Off Receiver (AN121, B410N), Dimmer Receiver (AD121, B410D) and Lantern Receiver (ED102).
House Code Position “B” “C” “D”
1st. set of On, Off button ID2 ID4 ID6 2nd set of On, Off button ID3 ID5 ID7
4 buttons are divided into two sets, consisting of one pc each of On and Off button. (Fig. 2)
Fig. 2 Fig. 3
1st. set
n
2
. set
House code slide switch
Note: Write down each designated lighting fixture in each group by adopting the
sticker affixed on the rear cover. (Fig. 3)
1
EMITTING THE ID CODE
In order to communicate with the EZ Alarm (SE131), ON/OFF Receiver (AN121,B410N) and Dimmer Receiver (AD121,B410D), it is essential that the same ID code is used between the Receiver and Transmitter.
Set the Receiver to the ID code learning mode. Press and hold the “OFF or button” on the Remote for 3 seconds until the LED extinguishes will emit the ID code to the receivers, subject to house code slide switch being set at the right position as mentioned below. The procedure of learning the ID code by the Receiver is clearly described on the Receiver’s manual.
OPERATION
1. To work with the EZ Alarm (SE131), set House code slide switch to the “A” position:
Remote’s operating status Remote’s RF
transmission Press the button Instant arm Instant Press the button Delay arm Delay Press the button Chime Chime Press the button Disarm/Learn (press
and hold for 3 seconds)
a. The LED will illuminate each time the button is pressed. b. The length of time to press the button may decide what kind of RF
signal will be sent to the Receivers. Press the button, an off radio signal will be emitted. Press and hold the button for more than 3 seconds until the LED extinguishes, a code learning command will be transmitted.
2. To be compatible with On/Off Receiver (AN121, B410N), Dimmer Receiver (AD121, B410D) and Lantern Receiver (ED102), set the house code slide switch to “B”, “C” or “D” position.
EZ Alarm operating status
Off/Learn
Remote’s operating status
Press 1st. set of On button Press 1st. set of Off button Press 1st. set of On & Off button simultaneously for more than 3 seconds Press 2nd. set of On button Press 2nd. set of Off button Press 2nd. set of On & Off button simultaneously for more than 3 seconds
a. Lock compulsorily
Pressing 1 will emit lock command to On/Off Receiver/Dimmer Receiver which will stop receiving signal from any other devices. However, lock command can be released by pressing “on” button on the Remote Transmitter or pressing the ON/OFF knob on the On/Off Receiver/Dimmer Receiver directly.
b. Pressing the “OFF” button will emit off signal to turn off the lighting fixture
connected to the On/Off Receiver (AN121, B410N) or Dimmer Receiver (AD121, B410D), whereas the code learning command will be transmitted by pressing the “OFF” button for more than 3 seconds until the LED extinguishes.
2
Remote’s RF transmission
On On Dimmer On, Off/Learn Off Dimmer Off Lock Lock compulsorily
On On Dimmer On, Off/Learn Off Dimmer Off Lock Lock compulsorily
st
. set of On & Off button simultaneously for more than 3 seconds
On/Off Receiver’s (AN121, B410N)
Operating status
(refer to ”a” as mentioned below)
(refer to “a“ as mentioned below)
Dimmer Receiver’s (AD121, B410D) operating status
Start/Stop
Lock compulsorily (refer to “a” as mentioned below)
Start/Stop
Lock compulsorily (refer to “a” as mentioned below)