Everspring Industry Co SP122 User Mamual

SP122 Wireless PIR Alarm
1 PIR Motion Sensor 6 2 Status LED 7 3
Low Battery LED 8
9
4 5
10 Siren
The Wireless PIR Alarm is designed to protect your property, serving as a security system and entry enunciator as well. Upon activation caused by temperature fluctuation of human movement, a piercing 130 decibels alarm sound or chime alert will be emitted.
INSTALLING BATTERIES
The Wireless PIR Alarm requires 4 “AAA” batteries. If the
LED of Alarm is flashing, the batteries need to be replaced right away, otherwise the Alarm cannot be working properly. Average battery life for typical usage is 1 year.
To install the batteries:
1. Remove screw at base of compartment and slide
off cover. (FIGURE 1a & 1b)
2. Insert 4 “AAA” batteries ensuring correct polarity
being put. (FIGURE 2)
FIGURE 1a & 1b
FIGURE 2 Note: Remove batteries before storing the Alarm for extended periods. Batteries corrode over time and may cause permanent damage to the unit. Different types of batteries or new and used batteries should not be mixed. Depleted batteries should be removed from the unit and disposed of properly.
CHOOSING A MOUNTING LOCATION
The Alarm is designed to be wall mounted. Since the PIR can be swiveled 90° rightward & leftward, plan the detection coverage according to the below options. (FIGURE 3)
90°
Option 1 Option 2 FIGURE 3
1
Option 1
TOP VIEW
8
6
4
2
0
2
4
6
8
180°
1.5
UNIT:m
20
864
Option 2
TOP VIEW
2
0
2
SIDE VIEW
1.5
204
68
UNIT:m
Note: We recommend that the Option 2 is applied to the stairway detection where visitors or intruders may pass through.
When considering and deciding upon the mounting position for the Alarm, the following points should be considered to ensure trouble free operation:
1. Do not locate the Alarm facing a window or where it
is exposed to or facing direct sunlight. The Alarms are not suitable for use in conservatories.
2. Do not locate the Alarm where it is exposed to
ventilators.
3. Do not locate the Alarm directly above a heat
source, (e.g. fire, radiator, boiler, etc).
4. Where possible, mount the Alarm on the flat wall at
a 1.5m height so that the logical path of an intruder would cut across the fan detection pattern. PIR Alarm responds more effectively to movement across the device than to movement directly towards it. (FIGURE 4)
FIGURE 4
5. Ensure that the position selected for the Alarm is
within effective range of the system.
INSTALLING THE PIR ALARM
Choose desired location and fix the battery cover on the wall using plastic wall plugs and screws provided. Place the Alarm to the battery cover and secure with the screw. (FIGURE 5)
FIGURE 5
STARTING UP
Upon completion of batteries insertion, the Alarm will have 60 seconds warm-up period. During this period, the Status LED keep flashing, any inputting or movement of human body will be ignored. The Status LED will be off after expiry of 60 seconds warm-up period.
The ex-factory mode is set for “off “ and 4-digit security code [
, , , ] has been set as the default secret code. When you remove the battery, pressing any button will clean out your previous setting. (Note: After removing or replacing the batteries, the Alarm security code would be automatically set back as default [
, ,
, ].
SETTING THE 4-DIGIT SECURITY CODE
Default setting: For initial operation, press [ code and then
, , ,
, , , ] 4-digit security
mode key, the Status LED and
LED will keep illuminating.
Press your new 4-digit security code and then mode key within 15 seconds. This 15-second period is designed for entering the new security code. If setting fails to be entered or incorrect codes were made for
2
three times consecutively within 15 seconds, the Alarm will skip to off mode automatically.
While setting the security code, no radio signal will be transmitted to the receiver if motion is sensed.
CODE LEARNING SETTING
Press [[
, , , ] 4-digit security code and then mode key to enter the code learning mode. The Alarm will transmit a radio signal to the receiver instantly. Upon completion of code learning transmission, the Alarm will skip to off mode automatically. During code learning mode, any input or activation will be ignored.
ARMING THE ALARM
Both “instant” and “entry delay” mode have a 15-second exit delay duration.
1. Instant mode: Arm the Alarm by pressing your
4-digit security code and then
mode key. The Alarm will have 15-second exit delay duration before the Alarm is armed. The delay allows time for you to leave the protected area without triggering the Alarm. During this 15-second delay duration, the Alarm will bleep and Status LED will flash as a notification. The Alarm will enter instant mode after expiry of 15-second exit delay duration.
When motion is sensed, the Alarm will sound for 30
seconds for each activation and emit a “Start” radio signal to the receiver simultaneously. After sending the radio signal for 15 minutes, the Alarm will transmit a “Stop” radio signal to the recei v er.
Note: We would recommend that the Alarm mode
is set for Chime when you are at home to avoid hearing damage resulted from frequent activation.
Loading...
+ 2 hidden pages