Everspring Industry Co SM103 Users Manual

SM103 DOOR/WINDOW DETECTOR
The Door/Window Detector is a Z-Wave with any Z-Wave Z-Wave
TM
logo can also be used with it regardless of the manufacturer, and ours
TM
enabled network. Z-WaveTM enabled devices displaying the
can also be used in other manufacturer’s Z-Wave of this Door/Window Detector on other manufacturer’s Wireless Controller menu allows remote turn-on of connected modules and their connected lighting when the Detector is triggered.
Adding to Z-WaveTM Network
In the rear casing, there is a tamper switch which is used to carry out inclusion, exclusion or association. Put a Z-Wave inclusion/exclusion mode, press the tamper switch on the detector to complete the inclusion/exclusion process.
Choosing A Mounting Location
The Door/Window Detector is suitable for mounting in dry interior locations only. Decide which doors/windows are to be protected by Door/Window Detectors,
(usually the front and back doors as a minimum will have Door/Window Detectors fitted). Additional detectors may also be fitted where required to other vulnerable doors or windows, (e.g. garage, patio/conservatory doors etc).
Note: Take care when fixing the Detect or to a met al frame, or mou nting within 1m of metalwork (i.e. radiators, water pipes, etc) as this could affect th e radio range of the device. If required, it may be necessary to space the magnet and detector away
TM
enabled device and is fully compatible
TM
enabled networks. Inclusion
TM
Wireless Controller into
Tamper Switch
from the metal surface using a plastic or wooden spacer to achieve the necessary radio range.
Installation
1. Undo and remove the fixing screw from the bottom edge of the Detector. Remove the rear cover.
2. Fit 3 1.5V AAA batteries supplied to the battery compartment.
3. With the tamper switch not being pressed on the Detector, detach or close the magnet from the Detector, the LED on the Detector will illuminate.
4. Using the rear cover as a template, mark the positions of fixing holes on the fixed part of the frame along the opening edge opposite the hinges using screws provided.
5. Refit the Detector to the rear cover and secure with the fixing screw supplied. Do not over tighten the fixing screws as this may distort or damage the casing.
6. Fit the Magnet to the moving part of the door/window opposite the Detector using the adhesive tape or 19mm fixing screws.
Ensure that the parallel gap between the Magnet and Detector is less than 10mm and that the matching line on the Magnet is pointing towards and aligned with the line on the Detector.
7. If several windows need to be protected, adopt the wire according to the specifications as mentioned below. This should be wired to the terminal block provided in the battery compartment in series connection. The wired contact should be connected using two core (24AWG) wire of maximum length 4m.
A cable entry cut-out is available and adjacent to the terminal block.
1
Internal connection External wired connection
You can choose either the internal or external wired connection, both of which types cannot be in existence at the same time.
Note: After removing batteries, wait for 5 seconds to refit batteries.
Operation
1. With the tamper switch not being pressed, the unit enters test mode, which allows the user to make a test. Detach the magnet from the Detector, the red indicator LED on the Detector will illuminate and the load or the lamp plugged into the On/Off Module AN135, Lamp Module AD130 will turn ON. It implies that the unit is working properly.
Close the door/window by replacing the magnet to the Detector will turn OFF the load or the lamp plugged into the On/Off Module AN135, Lamp Module AD130 and the red indicator LED on the connected load or lamp will be off too.
2. When the tamper switch is pressed, the unit enters normal mode. Open the door/window to detach the magnet from the Detector will turn ON the load or the lamp plugged into the On/Off Module AN135, Lamp Module AD130.
Close the door/window by replacing the magnet to the Detector will turn OFF the load or the lamp plugged into the On/Off Module AN135, Lamp Module AD130.
In normal mode with the tamper switch being pressed, the red indicator LED on the Detector will not illuminate to conserve battery life when the detector is triggered, (unless the battery is low).
3. By pressing the tamper switch for more than 5 seconds, and then release it. The Detector will send an alarm command (ALARM_REPORT, Alarm Type == 0x01, Alarm Level == 0x11) to the module, of which load or the lamp plugged into the On/Off Module AN135 o r Lamp Module AD130 will flash for 10 seconds.
Advanced Operation
The following information is for someone that has some experience setting up a Z-Wave system or someone that has computer software running a Z-Wave controller.
Enabling/Disabling Power Saving Function (for testing)
When the magnet is parted or closed from the Detector for 10 seconds, the SM103 will enter the power saving mode. It can be disabled or enabled power saving function by setting Configuration Parameter # 3.
This parameter can be configured with the value of 0 through 127, where 0 me ans power saving being enabled and others mean power saving being disabled.
PS : As long as the batteries have been refitted, the Detector will enable the power saving function automatically.
Configuring the OFF Delay
The Configuration parameter that can be used to adjust the amount of delay before the OFF command is transmitted is Configuration Parameter # 2. This parameter can be configured with the value of 1 through 127, where 1 means 1 second delay and 127 means 127 seconds of delay.
Configuring the Phase Level of ON Command
The Configuration parameter that can be used to adjust the phase level of ON command is transmitted is Configuration Parameter # 1. This parameter can be configured with the value of 0 through 127.
Value 0: Set Device OFF(0x00) Value 1-99: Set Device On (1-99) Value 100-127: Set Device On to the last phase (0xFF)
Note: 0xFF means the device will be on to the last phase that the device was turned