Everpure H-104, H-300+M, H-300, H-1200, H-300-HSD User Manual

Thank you for purchasing an Everpure commercial-grade water filtration system for your home. With your Everpure system, you get premium quality water direct from your tap that’s great-tasting, healthful and convenient for you and your family.
Product Specifications:
For Cold Water Use Only
• Temperature Range: 35-100°F (2-38°C)
• Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar)
• Service Flow Rate: 0.5 gpm (1.9 Lpm)
Gracias por comprar un sistema de filtración de agua Everpure de categoría comercial para su hogar. Con el sistema Everpure usted obtiene directamente de la llave un agua de primera calidad de buen sabor, saludable y en forma conveniente para usted y su familia.
Especificaciones Del Producto:
Para uso únicamente con agua fría
• Gama de temperatura: 2-38°C (35-100°F)
• Presión de servicio mín. - máx.: 0.7-8.6 bar (10-125 psi)
• Caudal de servicio: 1.9 Lpm (0.5 gpm)
Water Filtration System
Sistema de filtración de agua
Système de filtrage d’eau
INSTALLATION INSTRUCTIONS ENGLISH
Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1
Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 3,5
Basic Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . Page 3 –5
H 1200 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . Page 5–6
Claims & Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 6
INSTRUCCIONES DE INSTALACIÓN ESPAÑOL
Especificaciones Del Producto. . . . . . . . . . . . . . . . . . . . . . . . . Página 1
Herramientas necesarias. . . . . . . . . . . . . . . . . . . . . . . . . . . Páginas 7,9
Instrucciones básicas de instalación . . . . . . . . . . . . . . . .Páginas 7–9
H 1200 Instrucciones de instalación . . . . . . . . . . . . . . . .Páginas 9–10
Declaraciones y notas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Página 10
Everpure vous remercie de votre achat d’un filtre de qualité professionnelle pour votre logement. Avec votre système Everpure, votre famille et vous pourrez facilement tirer directement à votre robinet, de l’eau de qualité supérieure au goût excellent et bonne pour la santé.
Caractéristiques Techniques Du Produit:
Pour usage sur eau froide uniquement
• Gammes de températures : 2 à 38°C
• Pression utile mini. – maxi. : 0.7-8.6 bar
• Débit de service : 1.9 Lpm
Everpure Technical Services (8 00) 942-1153 7:00 AM –6:00 PM CST (Monday–Friday)
EV3070-43 Rev W AP07
Servicios Técnicos de Everpure (800) 942-1153 7:00 a 18:00 h, hora del centro de EE.UU. (Lunes a viernes)
INSTRUCTIONS D’INSTALLATION FRANÇAIS
Caractéristiques Techniques Du Produit . . . . . . . . . . . . . . . . . .Page 1
Outils nécessaires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 11,13
Instructions d’installation de base . . . . . . . . . . . . . . . . . .Pages 11–13
Consignes d’utilisation pour l’H 1200 . . . . . . . . . . . . . . . Pages 13–14
Revendication & remarques . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 14
Services Techniques Everpure (800) 942-1153 7h00 à 18h00 Heure Centrale des États-Unis (Lundi–Vendredi)
Notes • Notas • Remarques
• 2 •
WAT ER FI LTER MON ITOR
www.ev erpure.co m
THE OWNER’S GUIDE IS APPLICABLE FOR THE FOLLOWING EVERPURE FILTER MODELS:
Model H-54
Rated Capacity: 750 G (2835 L)*
Model H-300
Rated Capacity: 300 G (1140 L)*
Model H-300+M
Rated Capacity: 500 G (1892 L)*
* For optimum performance, cartridge
replacement is required once a year, or sooner if flow becomes too slow for convenience, or if the unit’s rated capacity is reached.
H 1200 customers: Instructions for installing the H-1200 begin on page 5 of this Installation and Operation Guide.
Model H-104
Rated Capacity: 1,000 G (3780 L)*
Model H-300-HSD
Rated Capacity: 300 G (1140 L)*
Model H-1200
Rated Capacity: 1,000 G (3780 L)*
BASIC INSTALLATION INSTRUCTIONS
Tools Needed For Installation
Phillips Screwdriver
• Wrench
• Utility Knife
• Measuring Tape
• Pencil
OPEN CARTON & INSPECT PARTS
1.
Installation Parts
Key Description Part No.
1 QL3 Filter Head EV9258-01 2 Filter Cartridge (varies) 3 2 Locking Washers EV3062-04 4 2 Screws EV3061-96 5 Angle Stop Valve Adaptor EV3121-20 6 Tubing, 1/4" poly A08601-19 7 Elbow Fitting Pack Restrictor EV3081-68 8 Teflon® Tape EV3121-19 9 Faucet Connector EV3121-35
10 Everpure Filter Timer EV9075-70
The Universal Plumbing Code adopted by over 20 states, and other specific state and county codes prohibit the use of saddle valves and their use is never recommended. You must adhere to your state/local plumbing codes. Consult your licensed plumber if you have related questions.
Do NOT use copper tubing with the John Guest Fittings provided with your Everpure Filter System. Copper tubing may appear to fit, but water leaks will develop over time and use. If copper tubing is required, you must use copper compression fittings available from any hardware/plumbing supply.
Multiple Appliance Connections: You can also connect your Everpure Filter to the refrigerator for ice and water, an instant hot dispenser or chiller, or a plumbed-in coffee brewer. Simply install connection “tees” (available from any hardware/plumbing supply) in the water line between the filter and the faucet adaptor, and run new tubing to each appliance.
NOTE: DO NOT connect this system to a commercial ice maker. These appliances require flow and volume beyond the design limits of your under-sink filter system.
NOTE: If connecting to a home icemaker and there is no filter faucet connection under the sink: A flush valve is required.
1
1
3
4
5
7
2
6
10
8
ENGLISH
VERIFY UNDER-SINK MOUNTING LOCATION
2.
Measure 22” from the base of the cabinet, and mark the mounting location for the top of the filter head. Make sure there is adequate space above the head to open and close the built in shut-off valve and to avoid crimping the water line tubing. Also, make sure your chosen location offers easy access for future cartridge changes..
DIMENSION Width Height Depth H-54 5" 15" 5" H-104 5" 20" 5" H-300 5" 22" 5" H-300 +M 5" w/monitor 22" 5" H-300-HSD 5" 22" 5"
NOTE: The head and cartridge must be mounted in the vertical position, with the cartridge hanging down.
9
2
22 "
• 3 •
MOUNT FILTER HEAD UNDER SINK
3.
Identify Filter Head and the two Elbow Fittings, and
A.
note that the Outlet Fitting has a black band. This fitting includes a small restrictor insert to insure maximum flow at 1/2 gallon per minute.
Apply Teflon Tape to the threads of each Elbow Fitting.
B.
Wrap tape in direction of the threads to assure a tight fit and avoid small leaks.
Screw Inlet Elbow Fitting into the left side of the filter
C.
head, and hand tighten only. Screw Outlet Elbow Fitting (black band) into the right
D.
ENGLISH
side of the filter head in the same manner. Securely mount the filter head on the cabinet wall using
E.
the enclosed mounting screws and washers.
ATTACH INLET WATER SUPPLY
1.
Locate and close the cold water Angle Stop Valve under
F.
your kitchen sink. Open cold water line of faucet to release water pressure.
Unscrew and disconnect the braided tubing on top of the
G.
Angle Stop Valve . Attach the bottom of Angle Stop Adaptor to the existing
H.
cold water Angle Stop Valve. Attach the braided tubing to the top of the Angle Stop
I.
Adaptor. Close side valve on Angle Stop Adaptor and open cold
J.
water Angle Stop Valve to return water service to kitchen sink. Check for leaks.
NOTE: Teflon® Tape should not be required for these next steps.
Measure length of tubing needed to connect Angle
K.
Stop Adaptor to Inlet Elbow Fitting on Filter Head. Allow adequate tubing to avoid sharp turns.
Cut tubing at a 90° angle using a sharp knife.
L.
Insert ends of tubing into quick-connect fittings. Push
M.
tube into fitting and gently pull to confirm a tight fit.
ATTACH FILTERED WATER TO SINK FAUCET
5.
Install separate faucet for filtered drinking water. Follow
N.
individual manufacturer’s instructions. Attach Faucet Connector Fitting to bottom end of
O.
threads on new faucet assembly. Teflon® Tape should not be required for this step.
Measure length of tubing needed to connect the
P.
Outlet Elbow Fitting on Filter Head to the new Faucet Connector Fitting. Allow adequate tubing to avoid sharp turns. Cut and insert each end of the tubing into the fittings.
OPTIONAL FILTER MONITOR (H300+M Filter System)
A Filter Replacement Monitor (EV3112-01) is included with the H300+M Filter System. It is a small water meter that counts the number of gallons used. This Monitor includes quick-connect fittings, and should be installed on the tubing between the filter system and the faucet connector.
Monitor Instructions (Document EV3112-52) are included with the H 300+M System.
3
4
5
C
D
B
E
F
I
G
H
L
M
N
• 4 •
P
O
WATE R FI LTER MONI TOR
www.ever pure.com
WAT ER F ILTE R MO NITO R
www.e verpure. com
INSTALL AND FLUSH FILTER CARTRIDGE
6.
Lift handle of the build-in shut off (QC Valve) on the
Q.
Head. Hold Head firmly with one hand.
R.
Align cartridge lug with label on filter Head.
S.
Insert filter Cartridge – Push upwards.
T.
Turn it to the right – About 1 ⁄4 turn – Until rotation stops.
U.
Open Side Valve of Angle Stop Adaptor and check for
V.
leaks up to Inlet Elbow Fitting. Open Filtered Water Faucet.
W.
Lower the QC Valve Handle to flush water to the sink.
X.
NOTE: Flush new filter cartridges for at least 3 minutes to remove air and any loose carbon. At first the water may appear cloudy due to trapped air in the filter and tubing. If water continues to be cloudy for more that one week, please contact Everpure Technical Services for assistance.
Remove plastic wrapper and pull Tab from back of
Y.
Everpure Filter Timer. The LED and buzzer will cycle 3 times to confirm the start. It is programmed to flash/ sound again in 11 months. Remove adhesive backing and mount Timer in a convenient location under the sink.
6
Q
R
V W
Y
S
T
Label
Lug
ENGLISH
U
X
H-1200 INSTRUCTIONS
Tools Needed For Installation
Phillips Screwdriver
• Wrench
• Utility Knife
• Measuring Tape
• Pencil
OPEN CARTON & INSPECT PARTS
1.
Installation Parts
Key Description Part No.
1 QL Twin Series Filter Head EV9272-25 2 Filter Cartridges (Set of 2) EV9282-01 3 2 Locking Washers EV3062-04 4 2 Screws EV3061-96 5 Angle Stop Valve Adaptor EV3121-20 6 Tubing, 1/4" poly A0860119 7 Elbow Fitting Pack Restrictor EV3081-68 8 Teflon® Tape EV3121-19