4. Position the cartridge on the guide seat in the bottom of the bowl. Then screw the bowl onto the head, by hand;
snug with filter wrench (EV3112-41)
5. Connect the water line to the inlet of the prefilter.
(Use 3/8" minimum piping on Coarse prefilter EV9795-80, use
1/2” minimum piping on EV9795-90). Connect outlet side to the next piece of equipment used.
6. If installing the E-Series prefilter for use with standard Everpure Quick Change filters, shut off the water supply to
the carbon filters by rotating the valve handles on the heads, to approximately the 9 o'clock position. If the ESeries prefilter is being installed to provide protection to an Everpure High Flow CSR water treatment system, shut
off main water supply, install the prefilter in front of the ball valve and an additional ball valve in front of the prefilter.
7. Turn on the water to the prefilter and press the red button on the head to open the pressure relief valve, purging air
from the system. When water begins coming through the pressure relief valve, release the button. Inspect the filter
assembly for leaks.
Your prefilter is now in service, prolonging the life of the carbon filters. Always keep a supply of replacement cartridges
on hand.
Cartridge Change
Replace prefilter cartridges when dirt has penetrated the center core of the cartridge or when the pressure gauge after
the prefilter indicates extremely low pressure during water flow.
1. Turn off inlet water valve and press the pressure relief valve.
2. Unscrew the bowl from the filter head, remove the used cartridge and empty the water from the bowl.
3. If the o-ring on the bowl feels dry, lubricate it with a high quality food grade silicone lubricant.
4. Clean the bowl with a mild solution of unscented dishwashing detergent. DO NOT use soap, strong or scented
detergents, chemical cleansers or abrasives.
5. Position the replacement cartridge on the guide seat in the bottom of the
bowl. Then firmly screw the bowl into the head by hand. Snug with filter
wrench (EV3112-41).
Filter Specifications
Head has 3/4" female pipe threads for inlet and outlet pipe connections: it is constructed of polypropylene. The clear bowls are constructed of transparent plastic for
easy visual inspection. The opaque bowls are constructed of polypropylene. Dirt/Rust
cartridges are graded density spool type, with synthetic materials.
Protect filter bowl from pesticide sprays.
Flow rate:
E10, 4 gpm (15 lpm) recommended
E20, 8 gpm (30.3 lpm) recommended
Capacity: variable, depending on local water quality
Pressure: 10-125 psig (0.3 - 8.6 bar), non-shock
Temperature: 35-100°F (2-38°C)
Unit dimensions: E10, 5.16" x 12.44 (13.1 x 31.6 cm)
E20, 5.16" x 22.44" (13.1 x 57 cm)
a clearance of 2" (5 cm) underneath is required for cartridge exchange
Cartridge length: EC110, 9.75" (25 cm)
EC210, 20" (50.7 cm)
Connections: 3/4" internal pipe thread (FPT)