Everpure CGHE1 User Manual

CGHE1 Installation & Operating Guide
Faucet Compatibility
Tools and Safety Equipment you may need (not provided)
Only “Open Vent” faucets function with a instant hot water dispenser tank.
Connecting a standard faucet will damage the tank and void the warranty.
2 mounting bracket screws (and 2 plastic anchors if attaching to drywall)
1
/4" (6.4 mm) O.D. copper tubing.
Materials required (not provided)
Components
tank mounting bracket
tank
When you purchase the Everpure®Commerical Grade Instant Hot Water tank, contents include:
quick-connect fitting
Shut-Off valve with “T” fitting (EV312120)
• ruler or measuring tape
• pliers
• hand or electric drill
• small drill bit for starter holes
• 1
3
/8" drill bit - if no sink
hole exists
• safety glasses
• bucket or pan
• open-end wrench(es)
• gloves
• tubing cutter
EVERPURE INSTANT HOT WATER DISPENSER
(Connections must meet all local codes and ordinances.)
This hot water dispenser produces instant hot water of approximately 190°F (88°C) as dispensed from the faucet.
This product is not intended to produce a continuous flow of hot water. The standard model will produce up to 60 cups of water per hour at approximately 190°F (88°C). Due to high water temperature, for safety reasons, the tank is not under pressure. Consequently, there is a slight delay of water flow after the faucet has been activated. This is normal and indicates that the expansion chamber is functioning properly.
IMPORTANT INFORMATION
560H486P01 REV E
quick-connect fitting with filter and cap
IMPORTANT SAFETY INSTRUCTIONS
PLEASE READ ALL INSTRUCTIONS VERY CAREFULLY
When using electrical appliances, basic safety precautions should always be followed including the following:
ELECTRICAL REQUIREMENTS
Recommended Ground Method
1. Read all instructions.
2. To protect against electrical shock, do not place cord, plugs, or appliance in water or other liquid.
3. Do not operate any appliance with a damaged cord or plug, or after the appliance malfunctions. Return appliance to the factory for examination, repair or adjustment. See Warranty insert.
4. Do not use outdoors or in damp area.
5. Do not let cord hang over edge of table or counter, or touch hot surfaces.
6. Do not use appliance for other than intended household use.
7.
When using this appliance, provide 4 to 6 inches of air space around the entire unit for air circulation.
8. Do not attempt to service this product. Repairs should be done by authorized service personnel.
9. Do not let children operate. The water can cause severe burns.
SAVE THESE INSTRUCTIONS. THIS PRODUCT FOR HOUSEHOLD USE ONLY.
The alert symbols displayed at right point to important safety information to make you aware of potential hazards that can cause serious injury or death. Please pay special attention to the information following these alerts and warnings. Failure to comply with these instructions can result in property damage, serious injury or death.
For your personal safety, the hot water dispenser is equipped with a power supply cord having a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, ground-type outlet, grounded in accordance with the National Electrical Code, ANSI/NFPA 70 — latest edition* or CSA Standard C22.1, Canadian Electrical Code, Part 1, — latest edition** and all local codes and ordinances.
If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have a properly grounded, 3-prong outlet installed by a qualified electrician.
Copies of the standards listed may be obtained from:
* National Fire Protection Association **CSA International
One Batterymarch Park 178 Rexdale Boulevard Quincy, MA 02269 Toronto, Ontario M9W1R3
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
A 120 volt, 60 Hz, AC only 15 or 20 ampere fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your hot water dispenser be provided.
NOTE: Use an outlet that cannot be turned on/off by a switch.
WARNING
DANGER
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter. Do not use an extension
cord. Failure to follow these
instructions can result in death, fire or electrical shock.
Faucet may be installed in spray hose opening in sink or drilled hole. If faucet is not to be installed in sink spray hose opening, cut 11/16
” (27mm) min. — 1
3
/8
” (35mm) max. dia. hole.
Important: Observe all governing codes and ordinances.
613/
16
(173 mm)
111/8” (283 mm)
81/16
(205 mm)
1. Make sure you have all necessary parts, tools and materials as suggested on manual cover.
2. Determine a convenient location to mount your faucet. This can be an existing sink hole in the sink top (the spray hose opening for example) or you may drill another hole into the sink or counter-top. As you determine the location of your faucet, consider the container you will use with the appliance, such as a large cooking pan. Location of the hole should also provide easy access for tank connections.
3. The thickness of the sink or counter must be less than 1
1
/8” (29mm).
4. Before connecting to the power source, the dispenser must be filled with water and the thermostat turned to the OFF position.
5. Do not use an extension cord with this appliance. Appliance must be within 36” (914mm) of the power source. See electrical requirements.
6. Plumbing connections must comply with all local codes and ordinances.
7. Do not use any pipe sealing compounds as they may get inside the dispenser causing an objectionable taste and odor.
OVERVIEW
HOT WATER CONCEPT
Unlike a household water heater, this dispenser tank is not pressurized for safety reasons. For a conventional household water heater, the faucet valve is placed after the heater tank resulting in a pressurized tank. For a hot water dispenser, the faucet valve is placed before the tank, creating an “open vent” style faucet and consequently no pressure is built up inside the tank.
Quick-connect fitting with filter and cap connects to cold water supply line. Filter and cap side points toward faucet.
Tank must be mounted vertically
See step 4 of installation for optional connections and instructions.
42” (1067 mm) max. — electrical outlet to tank
Loading...