B E N E F I T S
A P P L I C A T I O N / S I Z I N G
I N S T A L L A T I O N T I P S
O P E R A T I O N T I P S
CE S 290 0DP S eries
Wate r C onditio ner
Water Conditioning fo r Co mmer cial and Lig ht I ndus trial Applications
Available in Duplex Parallel System with 2” Porting
Hardness removal of 136,000 to 512,000 grains at
flow rates up to 145 gallons per minute continuous
Meter initiated regeneration minimizes salt, water,
and electrical costs
Advanced user-friendly controls incorporates
two time-tested hydraulically balanced pistons to
independently pilot service flow and regeneration
Large capacity brine tank maximizes time
between refills
Fiberglass reinforced resin vessels with NSF
approved polyethylene liners eliminate worries
about corrosion
Locate equipment on a smooth, level surface
Maintain an air-gap at the end of the drain line
Secure drain line directly over floor drain or
stand pipe
When connecting to a water heater, install a
check valve on the soft water piping to prevent
hot water back-up
When sweating/installing copper piping,
protect the control valve from excessive heat
Check local codes for additional equipment
that may be required, such as backflow
prevention devices (i.e., RPZ)
CES-2900E-136-DP: EV9984-42
CES-2900E-171-DP: EV9984-43
CES-2900
E-239-DP: EV9984-44
CES-2900
E-341-DP: EV9984-45
CES-2900
E-512-DP: EV9984-46
Check for softened water each time salt is
added, by using a soap or hardness test kit
Use a good quality grade of salt -Solar
or pellet are preferred
Check the salt level on a regular basis
Maintain at minimum salt depth of 6” to
ensure a proper regeneration
On iron bearing waters, use a salt that
contains an iron “fighting” additive, or use
a resin cleaner on a regular basis
Check the water level in the brine tank
If abnormally high - refer to IO guide for
troubleshooting information
Duplex parallel tank configuration for continuous
soft water supply and higher service flow rates
Warewashing
Laundry - Linen & Uniform
Boiler Scale Control
Water Heater Scale Protection/Reduction
General Housekeeping
C E S 2 9 0 0 D P S e r i e s
Overall Dimensions (inches):
Model
Number
CES-2900E-136-DP
CES-2900E-171-DP
CES-2900E-239-DP
CES-2900E-341-DP
CES-2900E-512-DP
Width Depth Height
(A) (B) (C)
64 28 79
70 28 82
81 34 82
87 34 89
99 34 97
Inlet Connection:
2” FNPT
Outlet Connection:
2” FNPT
Service Flow Rate (GPM):
Model
Number
CES-2900E-136-DP
CES-2900E-171-DP
CES-2900E-239-DP
CES-2900E-341-DP
CES-2900E-512-DP
Cont. @
15 PSI DP
94 121
106 137
114 148
123 159
145 188
Rated Capacity (grains per tank):
CES-2900E-136-DP 136,000
CES-2900E-171-DP 171,000
CES-2900E-239-DP 239,000
CES-2900E-341-DP 341,000
CES-2900E-512-DP 512,000
Pressure Requirements:
25-100 PSI (1.7 -6.9 bar) non-shock
Peak @
25 PSI DP
CES S ER IE S
WATER CO N D I T IO N E R
CES S ER IE S
WATER CO N D I T IO N E R
MR S- 20 T
C
LGR
F
EBI
SSALGREBI
F
S
KNAT
"2
Everpure water softening systems are covered by a limited warranty
against defects in material and workmanship for the following periods:
◆Complete System - 1 year
◆Control Valve - 5 years
◆Mineral Tank(s) -
◆6-13” diameter - 10 years
◆14” diameter and larger - 5 years
See printed warranty for details. Everpure will provide a copy of the
warranty upon request.
P
RENETFO
YLO
EN
IRB
KNAT
"2
2
"
A
A
RENETFOS
NA
T
K
"2
SS
B
"2
"2
The contaminants or other substances removed or
reduced by this water conditioning system are not
necessarily in your water. Do not use with water that is
microbiologically unsafe or of unknown quality
without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used
with disinfected water that may contain filterable cysts.
Temperature:
40º F to 100º F
Electrical:
115 VAC/60 HZ/1 Phase
Shipping Weight:
CES-2900E-136-DP 460 lbs.
CES-2900E-171-DP 880 lbs.
CES-2900E-239-DP 1210 lbs.
CES-2900E-341-DP 1750 lbs.
CES-2900E-512-DP 2750 lbs.
Operating Weight:
CES-2900E-136-DP 1990 lbs.
CES-2900E-171-DP 2610 lbs.
CES-2900E-239-DP 3690 lbs.
CES-2900E-341-DP 4780 lbs.
CES-2900E-512-DP 7060 lbs.
Everpure, LLC
1040 Muirfield Drive
Hanover Park, IL 60133
Ph: 630-307-3000 Fax: 630-307-3030