Everpower Electronics EPA 1204, EPA 1210, EPA 1207, EPA 1205, EPA 1215 Instruction Manual

...
7-STAGE AUTOMATIC
BATTERY CHARGER
MCU CONTROLLED & HIGH FREQENCY SWITCHMODE
Instruction Manual
Please read user manual carefully before use.
1
Before charging, read the instructions.
For indoor use. Do not expose to rain.
For charging 12 Volt or 24 Volt lead acid batteries ONLY.
Disconnect the 110V/220-240V AC mains supply before making or breaking
the connections to the battery.
The battery charger must be plugged into an earthed socket-outlet.
Connection to supply mains is to be in accordance with National wiring rules.
Do not attempt to charge non-rechargeable batteries.
Never charge a frozen battery.
If the AC cord is damaged do not attempt to use. It must be replaced or
repaired by a qualified person.
Corrosive substances may escape from the battery during charging and damage delicate surfaces. Store and charge in a suitable area.
Ensure all vehicle accessories including lights, heaters, appliances etc are turned off prior to charging.
This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
1. WARNING
7-STAGE AUTOMATIC CHARGING
This is a fully automatic battery charger with 7 charge stages.
Automatic charging protects your battery from being overcharged. So you can leave the charger connected to the battery indefinitely.
7-stage charging is a very comprehensive and accurate charging process that gives your battery longer life and better performance compared to using traditional chargers.
7-stage chargers are suitable for most battery types including Calcium, Gel and AGM batteries. They may also help restore drained and sulphated batteries.
The 7 stages are: Desulphation ; Soft Start; Bulk; Absorption; Battery Test; Recondition and Float.
2. FEATURES
2
Desulphation
The Desulphation stage may break down sulphation that occurs in batteries that have been left flat for extended periods of time, returning them back to full charge. sulphation occurs when lead-sulphate hardens and clogs up the battery cells.
Soft Start
A preliminary charge processes that gently introduces power to the battery. This protects the battery and increases battery life.
Bulk (Constant Current)
Bulk mode charges the battery at the maximum rate (constant current) putting a large amount of power into the battery in a short amount of time. This stage will charge the battery to approximately 80%, until the voltage reaches 14.4 volts for 12V charger or 28.8 volts for 24V charger.
Bulk mode for the charging cycle. The start phase continues until the battery's terminal voltage has risen above the set limit, at which point the charger switches to bulk charging. If the terminal voltage has not passed the voltage limit within the time limit, the charger switches to fault mode (lamp solid) and discontinues the charging. If so, the battery is faulty or its capacity is too large.
Absorption (Constant Voltage)
The charge rate slows down so the battery can absorb more power and reach 100% charge. The voltage remains at a constant 14.4 volts for 12V charger or
28.8 volts for 24V charge while the current is gradually reduced until no more power can be added without over-charging the battery.
Battery Test
An automatic battery test is conducted immediately after the absorption stage. The test monitors the voltage for 90 seconds to determine if the charge was successful.
12V charger If the voltage is below 13.2 volts (fail), the charger will initiate the Recondition stage.
12V charger If the voltage is above 13.2 volts (pass), the charger will proceed to the final stage: Float.
24V charger If the voltage is below 26.4 volts (fail), the charger will initiate the Recondition stage.
24V charger If the voltage is above 26.4 volts (pass), the charger will proceed to the final stage: Float.
This recondition stage can recover batteries from a deeply discharged state increasing performance and battery life.
RECOND- This mode is used to recover deep discharged flooded batteries where you could expect a stratified acid (high acid weight in the bottom, low on top). Check with battery manufacturer when in doubt. Use this mode with care, because the high voltage will cause some water loss. 16V/32V is normally no problem for electronics in 12V/24V system. Consult your supplier when in doubt. Life of light bulbs will be reduced at higher voltage. Try to disconnect light from the battery during this phase. Maximum effect and minimum risk for electronics is achieved by charging a disconnected battery.
Float
The Float stage maintains the battery at 100% charge without overcharging or damaging the battery. This means the charger can be left connected to the battery indefinitely.
The battery charger has an 7-step fully automatic charging cycle. the cycle is repeated infinitely. If the terminal voltage drops below a lower limit, the charger automatically goes back to the beginning of the charging curve.
Recondition
The battery reconditioning function is initiated automatically in the case that the battery fails the battery test (stage 5). Failing the battery test indicates that the absorption stage was unable to fully charge the battery. The recondition mode will then begin to introduce a low constant current for a period of 4 hours. Then the charger will go into float charging mode.
3
4
Using the latest technology in battery chargers, switch mode chargers convert 110V/220-240V AC power to 12V/24V DC power using electronic components unlike traditional battery chargers that rely on heavy transformers. This allows the charger to be light weight and compact without sacrificing on performance.
3. SWITCHMODE TECHNOLOGY
POLARITY PROTECTION
Prevents the output leads from sparking due to accidental reverse connection or short circuit, making the charger safer to use around batteries.
OUTPUT SHORT PROTECTION
Short circuit connection of the clips: Check clips are not touching each other OR Check the clips are correctly connected to the battery.
NON BATTERY LINK PROTECTION
BIf battery charger connects with non battery load,it will go into protection state.
FAULTY BATTERY
Bulk charging has timed out and stopped after 24 hours. Battery is faulty and may need to be replaced.
OVER VOLTAGE PROTECTION
The 12V charger will automatically protection if the voltage is higher than 17.5V. The 24V charger will automatically protection if the voltage is higher than 35V.
OVER TEMPERATURE PROTECTION
O
Internal temperature is above 65 C +/-5 C
COOLING FAN
The charger is fitted with a thermostatically controlled fan to cool onboard
electronics and maintain charging performance. The cooling fan will engage automatically when there is a high load on the battery or there is sufficient heat build up.
O
4. PROTECTIVE FEATURES
The 7-stage automatic charging consists of the following components:
LED Charge Status Display Indicates Power, Charging and Fully Charged
Power on LED
Fault LED
Power cord
DC leads
Thermostatically contro
5
5. PRODUCT OVERVIEW
Power on LED
Fault LED
5cm
Mounting hole
Mounting flange
Switch on/off
Thermostatically conrolled cooling fan
Quick connector
DC leads