Safety Precautions
Refer all work related to the installation of this product to qualified service personnel or
system installers.
Do not block the ventilation openings or slots on the cover.
Do not drop metallic parts through slots. This could permanently damage the appliance.
Turn the power off immediately and contact qualified service personnel for service.
Do not attempt to disassemble the appliance. To prevent electric shock, do not remove
screws or covers. There are no user-serviceable parts inside. Contact qualified service
personnel for maintenance. Handle the appliance with care. Do not strike or shake, as this
may damage the appliance.
Do not expose the appliance to water or moisture, nor try to operate it in wet areas. Do
take immediate action if the appliance becomes wet. Turn the power off and refer servicing
to qualified service personnel. Moisture may damage the appliance and also may cause
electric shock.
Do not use strong or abrasive detergents when cleaning the appliance body. Use a dry cloth
to clean the appliance when it is dirty. When the dirt is hard to remove, use a mild
detergent and wipe gently.
Do not overload outlets and extension cords as this may result in a risk of fire or electric
shock.
Do not operate the appliance beyond its specified temperature, humidity or power source
ratings. Do not use the appliance in an extreme environment where high temperature or
high humidity exists. Use the DVR at temperatures within 0°C~40°C / 32°F~104°F (Storage).
The input power source is 12VDC 3A (ECOR FHD 4F), 12VDC 5A (ECOR FHD 8F) and 12VDC
6A (ECOR FHD 16F).
Read Instructions
All the safety and operating instructions should be read before the unit is operated.
Retain Instructions
The safety and operating instructions should be retained for future reference.
Heed Warnings
All warnings on the unit and in the operating instructions should be adhered to.
ii
Follow Instructions
All operating and use instructions should be followed.
Cleaning
Unplug the unit from the outlet before cleaning. Do not use liquid cleaners, abrasive or
aerosol cleaners. Use a damp cloth for cleaning
Attachments
Do not use attachments not recommended by the product manufacturer as they may
cause hazards.
Water and Moisture
Do not use this unit near water-for example, near a bath tub, wash bowl, kitchen sink, or
laundry tub, in a wet basement, near a swimming pool, in an unprotected outdoor
installation, or any area which is classified as a wet location.
Servicing
Do not attempt to service this unit by yourself as opening or removing covers may expose
you to dangerous voltage or other hazards. Refer all servicing to qualified service
personnel.
Power Cord Protection
Power supply cords should be routed so that they are not likely to be walked on or pinched
by items placed upon or against them, playing particular attention to cords and plugs,
convenience receptacles, and the point where they exit from the appliance.
Object and Liquid Entry
Never push objects of any kind into this unit through openings as they may touch
dangerous voltage points or short-out parts that could result in a fire or electric shock.
Never spill liquid of any kind on the unit.
Battery
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to the instructions.
a. Use only two AAA dry cell batteries.
b. Do not dispose of the batteries in a fire as it may explode.
ATTENTION! This is a class A product which may cause radio interference in a
domestic environment; in this case, the user may be urged to take adequate measures.
iii
The information in this manual was current upon publication. The manufacturer reserves the right
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the users’ authority to operate this equipment.
This Product is RoHS compliant.
WEEE
Your EverFocus product is designed and manufactured with high quality materials and
components which can be recycled and reused. This symbol means that electrical and
electronic equipment, at their end-of-life, should be disposed ofseparately from your
household waste. Please, dispose of this equipment at your local community waste
collection/recycling centre. In the European Union there are separate collection systems
for used electrical and electronic product.
Please, help us to conserve the environment we live in!
This product complies with the High-Definition Multimedia Interface (HDMI)
Specification Adopter Agreement.
to revise and improve his products. Therefore, all specifications are subject to change without prior
notice. Manufacturer is not responsible for misprints or typographical errors.
Please read this manual carefully before installing and using this unit. Be sure to keep it handy for
later reference.
EverFocus ECOR FHD 4F / 8F / 16F is our new eZ.HD series full HD DVR, which adopts the latest
Analog HD technology, permitting it to deliver excellent high quality images of up to 1080p full HD
resolution that is far superior to traditional analog CCTV. The eZ.HD series is easy to install and can
integrate with the existing CCTV systems without re-cabling, so this new eZ.HD video surveillance
system will definitely be your best cost-effective solution.
The ECOR FHD 4F / 8F / 16F DVR supports 4 / 8 / 16-channel analog video inputs with resolution
ranging from D1, 960H, 720p to 1080p full HD and also features triple streams for live view,
playback and recording. In addition, this new series full HD DVR supports both standard coaxial
and UTP (Unshielded Twisted Pair) cable, allowing for long-distance transmission of full HD images
with zero video latency.
This model is designed with a high-performance hardware which has multiple video outputs for
local monitoring, audio in/out, alarm in/out, RS-485 serial interface, 2 USB interfaces and 1 RJ45
(10/100) Base-T Ethernet interface. Other than that, the ECOR FHD 4F and 8F / 16F and can be
expanded up to 1 and 2 SATA devices respectively, ensuring large capacity of the eZ.HD video
recordings.
EverFocus also provides mobile apps for users to view the eZ.HD camera streams via their mobile
devices (iOS or Android platforms) and also supports web UI for users to remotely access to the
surveillance system. Moreover, it is integrated with our powerful CMS platform, Genie XMS, so it
can be applied in more surveillance scenarios and easily scaled up in the future.
EverFocus also has an innovative function, eZ Hopper, for our new series of DVRs / NVRs, allowing
users to control up to 16 connected DVRs / NVRs with just one single mouse. This breakthrough
feature brings great benefits to the traditional small and medium-sized surveillance system, not
only eliminating the expense of the central monitoring software, but also saving the setup cost
and time.
ECOR FHD 4F / 8F / 16F Full HD DVR
2
IR Remote Control
a
*Internal 3.5" HDDs (Optional)
*eZ.HD Camera
Line Level
Audio Out
Alarm In / Out 1~4
**Main Monitor
(HDMI)
Call Monitor
(BNC)
Web Remote
Client
CMS:
Genie XMS
Mouse / USB / EKB200
Line Level
Audio Out
**Main Monitor
(VGA)
Power
Supply
RS-485 Device:
EKB500 / PTZ Camera
Line Level
Audio In 1~4
Network
or Radio Clock
Mobile App:
MobileFocus
MobileFocusHD
Mouse / USB / EKB200
COM NO G G 4 3 G G 2 1
ECOR FHD 4F / 8F / 16F System Diagram
* This diagram uses ECOR FHD 8F as an example. ECOR FHD 16F has 16 Video Inputs; ECOR FHD 4F
only has 4 Video Inputs and supports only 1 hard disk drive.
**The HDMI and VGA port can be all used as the Main monitor outputs and share the identical
functionality.
ECOR FHD 4F / 8F / 16F Full HD DVR
3
1.1 Features
• Megapixel resolution over standard coaxial / UTP (Unshielded Twisted Pair) cable
• eZ upgrade to full HD resolution
• 1080p full HD, 720p, 960H or D1 simultaneous video inputs
• H.264 compression format for enhancing recording capacity and improving network image
transmission speed
• eZ.Controller function: Control camera OSD settings and PTZ operation directly from DVR
end
• Multiple Monitors: Separately configured HDMI and VGA Monitor outputs
• High bandwidth full HD recording with recordable reduced bandwidth stream for mobile or
multiplexed viewing applications.
• Supports live monitoring and playback of video from mobile devices via MobileFocus (Plus) /
MobileFocusHD (Plus) Apps
• Multiple Control Inputs: mouse / front panel / IR remote controller
• Remote configuration supports from built-in web interface
• Ethernet interface for remote network viewing and control
• eZ Hopper function: Only one mouse to control up to 16 connected EverFocus DVRs / NVRs
• Supports radio-controlled clock for time synchronization
• Integration with Genie XMS CMS
• Multi-language supported
ECOR FHD 4F / 8F / 16F Full HD DVR
4
•
•
1.2 Packing List
ECOR FHD 4F / 8F / 16F DVR x1
• HDD Mounting Screw Pack x 1 • Quick Installation Guide x 1
•
Remote Controller x 1 • SATA Cable x 1 (ECOR FHD 4F)
• Mouse x 1
• CD x 1 (contains the IP Utility software,
User Manual and Quick Installation Guide)
Note:
1. Equipment configurations and supplied accessories vary by country. Please consult your
local EverFocus office or agents for more information. Please also keep the shipping
carton for possible future use.
2. Contact the shipper if any items appear to have been damaged in the shipping process.
3. Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to the instructions.
a. Use only two AAA dry cell batteries.
b. Do not dispose of the batteries in a fire as it may explode.
Power Cord and Adaptor x 1
x 2 (ECOR FHD 8F)
x 2 (ECOR FHD 16F)
1.3 Optional Accessories
•EKB200 (USB controller keyboard: connect to the PC or DVR to control the PTZ cameras
connected to the DVR). Please refer to 6.9.6 EKB200 Setting and the User Manual of
the EKB200 Keyboard.
•EKB500 (RS-485 keyboard: connect to the RS-485 port to control the PTZ cameras
connected to the DVR). Please refer to User Manual of the EKB500 Keyboard.
ECOR FHD 4F / 8F / 16F Full HD DVR
5
1
2
4
5
6
7
8
9
10
11
12
3
3
6
2
11
10
12
1
89
3
6
13
1110
12
1
89
1.4 Front Panel
ECOR FHD 4F
ECOR FHD 8F
ECOR FHD 16F
ECOR FHD 4F / 8F / 16F Full HD DVR
6
No. Name Description
1 USB2.0 Port
The USB2.0 port for connecting to a mouse, external storage device or
EKB200 keyboard.
2 View Press the type of layout you want for displaying your channel feeds.
3 SEQ (Sequence)
4 Display
Press to enter the automatic sequence mode. This will show each
channel feed in sequence.
Press to cycle between the info display types (channel and status bar
info).
5 Search Press to enter the Search Setup menu.
6 Copy Press to enter the Copy Menu.
7 Zoom
Press repeatedly to toggle between 2x and 4x zoom. Press the Menu
button to switch zoom off.
8 Arrow Keys Use these arrow keys to change the Menu settings.
9 IR Receiver Receiver for IR Remote Control.
Power LED: Indicates the power is on.
10 Status LED
Record LED: Indicates the DVR is recording.
Alarm LED: Indicates the alarm input is triggered. (Note: ECOR FHD 16F
doesn’t have Alarm LED).
11 Menu Press to enter/exit the Main Setup Menu.
Channel 1~4 /
12
1~8 / 9~16
13 Channel Switch
Press to display the channel in full screen.
Press this button to switch the above channel button numbers between
1~8 and channel 9~16.
7
1.5 Rear Panel
2
3145
689
10 11 12
7
COM NO G G 4 3 G G 2 1
2
3
1
4
5
6
8
9
10
11
12
7
COM NO G G 4 3 G G 2 1
3
1
4
5
6
8
9
10
11
12
7
2
COM NO G G 4 3 G G 2 1
ECOR FHD 4F
ECOR FHD 8F
ECOR FHD 4F / 8F / 16F Full HD DVR
ECOR FHD 16F
ECOR FHD 4F / 8F / 16F Full HD DVR
8
No. Name Description
Connect up to 4 / 8 / 16 analog HD or SD cameras to any
channels using the coaxial cables. (The eZ.HD series DVR
doesn’t support HD-TVI / HD-CVI / HD-SDI cameras.)
Note: The DVR can automatically configure itself as NTSC or
1 Video Input
PAL. To do this, connect a camera to any channel of the DVR.
The DVR will detect the first connected camera format (NTSC
or PAL) and then automatically configure itself to the
detected format from the first connected camera. For
example, if the format of the first connected camera is NTSC,
the DVR will configure itself to NTSC format.
2 Call Monitor Port (BNC) Connects to the Call monitor using a BNC cable.
Connects to the audio input devices such as microphones.
3 Audio Input 1~4 (RCA)
Note that the microphone with a (built-in) amplifier and
external power supply is required.
Connects to 4 alarm inputs, and to 1 alarm output device.
4 Alarm Input / Output
You can also connect to the radio-controlled clock for time
synchronization. Please refer to 2.2.2 Alarm I/O.
5 Power Switch Press to turn on or off the power.
6 Main Monitor Port (HDMI) Connects to the Main monitor using a HDMI cable.
Connects to the audio output devices, such as speakers.
7 Audio Output RCA
Note that the speaker with a (built-in) amplifier and external
power is required.
8 Main Monitor Port (VGA) Connects to the Main monitor using a VGA cable.
9 LAN Connects to the Network.
10 USB Interface
11 RS-485 Port
12 Power Port
The USB2.0 port for connecting to a mouse, external storage
device or EKB200 keyboard.
Connects to the RS-485 device, such as EverFocus’ EKB-500
keyboard.
Connects to the DC 12V power using the supplied Power
Cord.
ECOR FHD 4F / 8F / 16F Full HD DVR
9
COM NO G G 4 3 G G 2 1
2
2. Installation
2.1 Hard Disk installation
ECOR FHD 4F:
You can install one 3.5” HDD inside the ECOR FHD 4F DVR for recording videos.
1. Make sure the DVR is power-off.
Chapter
2. Unscrew the three housing screws on the rear panel of the DVR.
3. Push the housing to the back and open it.
ECOR FHD 4F / 8F / 16F Full HD DVR
10
4. Screw the HDD to the bottom of the DVR using supplied screws.
5. Connect the internal SATA cable to the SATA port of the HDD.
6. Connect the internal power cable to the HDD.
7. Screw back the hosing to the DVR.
8. Format the HDD after the installation is completed.
ECOR FHD 4F / 8F / 16F Full HD DVR
11
SATA CablePower Cable
ECOR FHD 8F / 16F:
You can optionally install two 3.5” HDDs inside the ECOR FHD 8F / 16F DVR for recording videos.
1. Follow the first three steps above to open the DVR housing.
2. Please install the HDD firstly on the HDD Bracket and then install the second one onto the
DVR.
2
3. Screw a HDD onto the HDD Bracket using the supplied four short screws.
1
4. Connect the internal SATA cable to the SATA port of the HDD, and connect the internal
power cable to the HDD to complete the first HDD installation (You need to connect these
cables to the second HDD before installing).
ECOR FHD 4F / 8F / 16F Full HD DVR
12
5. Screw the second HDD on the DVR from the bottom side using the supplied four long
screws.
6. Screw back the housing to the DVR.
7. Format the HDD after the installation is completed.
2.1.1 Hard Disk Compatibility List
Please go to the ECOR FHD 4F / 8F / 16F Web page (Download tab) on our website
http://www.everfocus.com.tw to see the latest Hard Disk Compatibility List and it’s
recommended to use the hard disk models in that list to ensure your hard disks will be
compatible.
Note: If using two or more hard disks, please choose the hard disks with the same capacity.
ECOR FHD 4F / 8F / 16F Full HD DVR
13
eZ.HD Camera
Line Level
Audio Out
Main Monitor
(HDMI)
Web Remote
Client
CMS:
Genie XMS
Mouse
Line Level
Audio Out
Main Monitor
(VGA)
Power
Supply
Line Level
Audio In 1~4
Network
1
2
3
4
4
5
6
7
COM NO G G 4 3 G G 2 1
2.2 Basic Connection
The instructions below the figure describe the basic connection for the ECOR FHD 4F / 8F / 16F
DVR. (This figure uses ECOR FHD 8F DVR as an example).
1. Connect the cameras to the DVR using the coaxial cables. eZ.HD cameras are recommended.
2. Connect the line level audio input devices to the Audio-in 1 ~4 RCA sockets of the DVR. Note
that the audio input devices, such as microphones, are required to have a (built-in) amplifier
and external power supply. Please refer to 1.5 Rear Panel.
3. Using the supplied Power Cord, connect one end to the DC 12V port on the DVR and the
other end to the DC 12V power outlet.
Note: Please ensure to connect the internal power cables to the internal HDDs before
powering on the DVR.
4. To view videos and control OSD settings, connect a monitor to the HDMI or VGA port using
the HDMI or VGA cable supplied by the monitor manufacturer.
5. To listen to audio of video source, connect speakers to the Audio-out RCA port. Note that
speakers with a (built-in) amplifier and external power are required
.
6. Use a standard RJ-45 cable to connect the DVR to the network for remote viewing or using
EverFocus surveillance system (Genie XMS).
7. Optionally connect a mouse to the DVR to control the system. You can also control the
system using the supplied IR Remote Control or the control keys on the front panel.
ECOR FHD 4F / 8F / 16F Full HD DVR
14
Main Monitor
Call Monitor
Main Monitor
BNC Cable
VGA Cable
HDMI Cable
COM NO G G 4 3 G G 2 1
2.2.1 Monitor Connection
Connect the monitor to the HDMI, VGA or BNC port on the rear panel of the DVR. The ECOR FHD
4F / 8F / 16F DVR provides 2 main monitor outputs with identical functionality - VGA and HDMI.
Both outputs can be used simultaneously and deliver full HD output resolution (1920x1080,
progressive, 60 Hz. vert., 68 KHz hor.). Make sure that the connected monitor's specifications
comply with these resolution requirements (This figure uses ECOR FHD 8F DVR as an example).
Note:
1. The connected monitors’ specifications must comply with the resolution requirements.
2. Do not exceed the max. HDMI cable length of 15 meters. The standard HDMI cables can
support cable length up to 3 meters. For longer distances, such as 15 meters, it is highly
recommended to use high quality HDMI cables.
ECOR FHD 4F / 8F / 16F Full HD DVR
15
COM NO G G 4 3 G G 2 1
Alarm OutAlarm In
Alarm
Radio-controlled Clock
Description
ALMIN
GND
ALMIN
GND
Alarm Input with N.O. contact in idle stateAlarm Input with N.C. contact in idle state
ALMOUT+
ALMOUT-
Alarm Output with N.O. contact
2.2.2 Alarm I / O
The DVR provides 4 alarm inputs and 1 alarm outputs. You can also connect the
radio-controlled clock to the alarm input of the DVR for the time synchronization. The DVR
supports the radio-controlled clock which will automatically synchronize to the time standard
so that you won’t need to reset the time manually. Please refer to the table below for PIN
assignment.
Alarm Input
No.
1-4
ALM_IN1 – ALM_IN4
G GND
Alarm Input Contacts
This DVR provides one alarm input per camera. All inputs are programmable N.O. (Normal
Open) or N.C. (Normal Closed). All settings are programmed in the ALARM / Event menu.
Alarm Output Contacts
The relay output provides Normally Open dry contacts.
ECOR FHD 4F / 8F / 16F Full HD DVR
16
Rear View
RS-485 Port
EKB500
RS-485
RJ-45 Cable
Connector Box
PTZ Camera 1~8
COM NO G
G 4 3 G G 2 1
2.2.3 RS-485 Port
The RS-485 port, located on the rear panel of the DVR, can be used to connect to an RS-485
keyboard, such as EverFocus’ EKB500, for controlling PTZ cameras or connect to a POS device. For
details on the RS-485 configurations on the DVR, please refer to 6.9.5 I/O Control. This figure uses
ECOR FHD 8F DVR as an example.
2.3 Turning On / Off the Power
Before powering on the DVR, please make sure the internal HDDs have been installed properly.
Once you have completed the basic cable connections, you are ready to turn on the DVR.
To turn on the power, connect the supplied Power Cord to the power outlet and turn on the
Power Switch. All of the LED indicators on the front panel will light up. The DVR will automatically
run an internal process, when the process is complete, the LED indicators will turn off, and the
POWER LED will remain light up in green. And then you can start operating the DVR.
To turn off the power, please go to OSD Root Menu > System Setting > Miscellaneous setting page,
and click Shutdown (refer to 6.9.7 Miscellaneous). After the message pops up as below, you can
now turn the Power Switch to the "Off" position.
ECOR FHD 4F / 8F / 16F Full HD DVR
17
2.4 Checking the Dynamic IP Address
You can look up the IP address and access the Web interface of the DVR using the IP Utility (IPU)
program, which is included in the software CD. The IP Utility can also be downloaded from
EverFocus’ Website: http://www.everfocus.com/HQ/Support/DownloadCenter_p1.aspx. Please
connect the DVR on the same LAN of your computer.
1. Save IP Utility Setup .exe in your computer. Double click the .exe file and follow the
on-screen instructions to install the IP Utility.
2. Click the Finish button, the IP Utility will be automatically launched to search the IP devices
connected on the same LAN.
ECOR FHD 4F / 8F / 16F Full HD DVR
18
3. To optionally configure the Machine Name, IP Address, IP Type or Port Number using the
IPU:
a. Log in the DVR by checking the desired model and then click the Log in icon. The
Log in dialog box appears.
b. Type the Username and Password. Click the OK button, the status of the selected camera
will display Login.
Note:
1. The default user ID is admin and the default password is 11111111.
2. If you select more than one DVRs that have the same user ID / password, you will
be able to log in several DVRs at once.
c. Right click the column to configure the setting. Click Apply Changes button to apply
and save the settings.
Note: Most networks uses DHCP to assign IP address, if you are unsure of your network
settings, please consult your network administrators for configuration details.
4. To access the Live View window, double click the IP address of the desired device, the login
window pops up. Type the user ID and password to log in. By default, the user ID is admin
and the password is 11111111.
ECOR FHD 4F / 8F / 16F Full HD DVR
19
5. If you log in for the first time, follow the instruction steps on the interface to update the
latest Plugin version (ePlayer). After reloading the webpage, the login window pops up again.
Type the user ID and password to log in again. By default, the user ID is admin and the
password is 11111111.
Note for the first time login:
The “Download ePlayer Instruction” page will only be prompted for the first time login in
order to update the system to the latest plugin version.
When the Plug-in blocked appears on the browser, select Always allow plug-ins on xxx, click
Done and then reload the webpage.
6. Now you will be able to see the remote live page.
ECOR FHD 4F / 8F / 16F Full HD DVR
20
If you encounter the following problem or still can’t access the remote Web interface, please
see below:
If the Error window appears, pleasebe sure tocloseALL the Web browser windowsfirst and
then click Retry. When the Completing the ePlayer Setup Wizard window shows up, click Finish. Then, you can open a new browser again to access the DVR’s remote Web interface.
ECOR FHD 4F / 8F / 16F Full HD DVR
21
If your PC or laptop is running with Windows, it’s required to run the browser as
administrator when first entering the remote web page of the device. Go to C:\Program Files (x86)\Internet Explorer, right-click the browser and then click Run as administrator.
You may need to turn User Account Control off if you still can’t see the Remote Live View. On
the computer, click Start > Control Panel > System and Security > Action Center (click
Change User Account Control Settings), the User Account Control Settings window appears.
Adjust the slide bar to Never Notify and then click OK. Restart your computer if requested.
ECOR FHD 4F / 8F / 16F Full HD DVR
22
High-speed modem
Internet
Straight-through LAN patch cable
Router
Cat 5 Straight Through Cable
Left: Pinout of a straight-through cable.
2.5Connecting the DVR to the Network
There are three methods to connect the DVR to the network: Router or LAN Connection, Direct High‐Speed Connection and One‐to‐One Connection. For more information of the network,
please refer to Appendix A. Network Overview.
2.5.1 Router or LAN Connection
This is the most common connection in which the DVR is connected to a router and allows
multiple users on and off site to see the DVR on a LAN/WAN (Internet). The DVR must be
assigned an IP address that is compatible with its LAN. By setting up port forwarding on the
router, you can remotely access the cameras from outside of the LAN via the Internet. To
remotely access the Web interface, please refer to 7. Remote Access to the DVR. To set up
port forwarding, please consult the manual of the router or refer to Appendix B: Linksys & D-Link Port Forwarding.
Connection Procedure:
The First step is to purchase or make a straight through cable. We recommend
purchasing one if you have never made a straight through cable. Please remember you
can not use a cross-over network cable for this application.
Once you have a straight through cable, plug one end into the LAN port on the back of
the recorder and the other into the router.
Log into the EverFocus DVR menu and go to the Network Setting Menu.
To let the router automatically assign an address:
Loading...
+ 127 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.