EverFocus EP4CQ User Manual

EverPlex 4CQ
USER'S MANUAL
EverPlex 4CQ
High Resolution, Broadcast Quality
Playback Zoom Function
RS232 Remote Control
+
Freeze
Seq
NEXT P. DEFAULT
Set
Connect Up To 4 Cameras
Ver. 1.0
Table of Content
Notice.........................................................................................................................1
Important Messages..................................................................................................2
Introduction...............................................................................................................3
Specification..............................................................................................................4
Chapter I Functional Description....................................................................
1. Front Panel Keypads..........................................................................................5
1.1 Full Screen ....................................................................................................5
1.2 Quad Display ................................................................................................5
1.3 Freeze ........................................................................................................5
1.4 Sequential Switching.....................................................................................5
1.5 VCR Play Back.............................................................................................5
1.6 Set ........................................................................................................6
1.6.1 Date, Time Setting, and OSD display on/off setting...............................7
1.6.2 Alarm Records........................................................................................7
1.6.3 Set the Brightness, Contrast, Color, Tint for each channel.....................8
1.6.4 Set the camera titles................................................................................8
1.6.5 Set sequential switching parameters.......................................................8
1.6.6 Set alarm parameters...............................................................................9
Chapter II Back Panel Connection ...............................................................10
1. BNC Connectors..............................................................................................10
1.1 Monitor .......................................................................................................10
1.2 VCR out ......................................................................................................10
1.3 VCR In ....................................................................................................10
1.4 Video input..................................................................................................10
2. Alarm Connectors (DB-15).............................................................................10
2.1 Alarm out ....................................................................................................11
2.1.1 Normally open connection....................................................................11
2.1.2 Normally closed connection .................................................................11
2.2 Alarm in and alrm reset...............................................................................12
2.2.1 Alarm in................................................................................................12
2.2.2 Alarm reset............................................................................................13
3. RS232 Connector.............................................................................................13
3.1 The pin assignment of the 9 pin D-SUB connector.....................................14
3.2 Transmission setting....................................................................................14
3.3 Remote control protocol..............................................................................14
3.4 Alarm message sent via RS232...................................................................15
5
Notice
1
This manual is presented to the users of EverPlex 4CQ by EverFocus Electronics Corp. With years of engineering researches, EverFocus has spared no effort to provide the high quality products to the worldwide users. For the policy of continual product improvement, EverFocus reserves the right to make changes to the product specifications and documentation without notice. All the components of the products, including accessories, components, and outlook, are based on the agreements if each deals to satisfy all kinds of users. Meanwhile, please be advised that every step of operation must follow the instruction of this manual to keep EverPlex 4CQ working under the best condition. Please notice that EverFocus will not be charged any claims or renewing cases resulted from inappropriate operation.
2
Important Messages:
1.
To prevent fire or shock hazard, do not expose this equipment to the environment of high humidity and dust. So, do not use it in an unprotected outdoor installation or any area classified as a wet area.
2.
Installation environment: The temperature should be kept between
o
C ~ +50oC, humidity under 90%. For safety sake, do not
-10 disseminate the unit or put it on an unstable base.
3.
Ventilation: Openings in the enclosure are provided for ventilation and to ensure reliable operation of the unit and to protect it from overheating. These openings must not be blocked or covered. This unit should not be placed in a built-in installation unless proper ventilation is provided.
4.
Cleanse: Unplug the unit from the outlet before cleansing. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth to clean it.
5.
Overload: Do not overload outlets and extension cords as this may result in a fire or electric shock.
6.
Power-cord Protection: Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.
7.
Object and Liquid Entry: Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit.
8.
Service: Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage of other hazards. Refer all servicing to qualified service personnel.
Introduction
EverPlex 4CQ, a real time color Quad and 4 channel auto switcher, is the best choice for multiple monitoring and recording.
The superior video quality is achieved by adopting the advance multi-media technology. The picture of Quad display is sharp and clear because Everplex 4CQ is featured with CCIR601 full resolution and 16 million colors.
Main Features:
Real-time Quad display.
High Resolution 720 x 576 (PAL), 720 x 480 (NTSC).
3
16 million colors.
Up to 4 camera inputs and quad display.
Video loss detection.
Different border colors indicate page selection.
Independent brightness, contrast, color and tint adjustments for every
channel. Built-in timer and and title generator.
Alarm input with built-in buzzer.
Programmable Quad and 4 channel auto switcher outputs.
Playback Zoom and Freeze function.
RS232 Remote Control.
User-friendly front panel design.
4
Specification
Video input: 4 cameras + 1 VCR inputs
Video output: Video output x 2, 1V p-p/75 ohm
Title: Up to 6 characters
Timer: Built-in real time clock
Alarm input: 4 alarm inputs and 1 alarm reset input
Alarm output: 2 Alarm Out (1 Normally Open, 1 Normally Closed)
Dimension: 239 x 166 x 55 mm
Power source: AC 24V or DC 12V
Power consumption: 17W max.
Chapter I Functional Description
5
EverPlex 4CQ
1. Front Panel Keypads
1.1 Full Screen
Press any key of FULL SCREEN, the picture of the corresponding quadrant will fill the whole screen of the monitor display. Press the same key again, the quad display will come out.
1.2 Quad Display
Press the Quad Display, the picture of the quadrant video will fill the whole screen of the monitor display.
1.3 Freeze
During quad display mode, you can press FREEZE key to freeze the video on the monitor. Press this key again to de-freeze the video. If you press any Full Screen Key, there will be merely that video input de-frozen. Judging by the channel title blinking, users can be aware of freezing status.
+
Freeze
Seq
NEXT P. DEFAULT
Set
1.4 Sequential Switching
Press SEQ key will enter the auto sequential switching mode, the switching sequence is programmed in SET function. It can be displayed live quad and full screen sequentially on the main monitor according to the programmed switching sequence. Press the SEQ key again to exit the auto sequential mode and stay the last screen display.
1.5 VCR Play Back
Press PLAY BACK key to play back the recorded video from VCR. There are two special functions implemented in the play back mode.
A. ZOOM function
Pressing any FULL SCREEN key during playback will zoom in the picture of the corresponding quadrant to the whole screen of the monitor display. Press the same key again to stop the zoom function and go back to the normal playback video.
B FREEZE function
Press the FREEZE key during zoom mode to freeze the current frame. Pressing this key again to de-freeze the video.
6
1.6 Set
Press the SET key to set time/date, title on/off, picture, camera titles, switching sequence, switching time period, alarm sensor type, alarm hold time, and the alarm/video loss records displaying.
There are 6 pages in the setting mode :
Page 1 : Set Time and Date.
Turn ON/OFF the time, date, title display for Quad or Full screen
display. Page 2: Display the alarm records. Page 3: Set the brightness, contrast, color, and tint for each camera. Page 4: Change the title name of each camera. Page 5: Program the sequential switching sequence and switching hold
time. Set the screen refresh mode. Page 6: Set the alarm sensor type, alarm hold time, buzzer on/off and
Security.
The following keys are re-defined in setting mode (Definition under the keypad).
Press “NEXT P.” to go to the following pages for setting.
NEXT P.
Press the “DEFAULT” to reset the setting.
DEFAULT
Press the +/- keys to set the value.
+
Press the cursor key to select the item to set.
1.6.1 Date, Time setting, and OSD display on/off setting
DATE: 2000-01-01 TIME: 01:01:01
QUAD SCREEN DATE: ON QUAD SCREEN TIME: ON QUAD SCREEN TITLE: ON
FULL SCREEN DATE: ON FULL SCREEN TIME: ON FULL SCREEN TITLE: ON
VERSION N.NN
DATE data format is CCYY-MM-DD, where
CC : Century code from 19 to 20 YY : Year data from 00 to 99 MM : Month data from 01 to 12 DD : Day data from 01 to 31
7
TIME data format is HH-MM-SS, where
HH : Hour data from 00 to 23 MM : Minute data from 00 to 59 SS : Second data from 00 to 59
VERSION shows current firmware version
1.6.2 Alarm Records
ALARM RECORDS
C A DATE TIME
3 S 1997-03-24 10:00:00
The Alarm Record format is : (C A DATE TIME)
C : the channel number from 1 to 4 which invokes the alarm A : Alarm type, 'S' - alarm from sensor input, 'V' - alarm from video loss detection DATE, TIME : the date and time when the alarm happens
8
1.6.3 Set the Brightness, Contrast, Color, Tint for each channel
Video Display Set Up
BRIGHT: 32 BRIGHT: 32 CONTRAST:27 CONTRAST:27 COLOR: 31 COLOR: 31 TINT: 32 TINT: 32
BRIGHT: 32 BRIGHT: 32 CONTRAST:27 CONTRAST:27 COLOR: 31 COLOR: 31 TINT: 32 TINT: 32
1.6.4 Set the camera titles
Camera Title Setup
CH1: CH1
CH2: CH2
CH3: CH3
CH4: CH4
1.6.5 Set sequential switching parameters
Sequential Switch Menu
CH1: ON CH2: ON CH3: ON CH4: ON QUAD: ON
SWITCH TIME : 03 SEC
REFRESH MODE : FIELD
CH1 - CH4 to turn each channel ON or OFF in the sequential switching QUAD to turn QUAD display ON or OFF in the sequential switching
SWITCH TIME : The time period to switch for each switching item REFRESH MODE : To set the screen refresh by 'FRAME' or by 'FIELD'.
1.6.6 Set alarm parameters
Alarm Setting Menu
CH SENSOR
1 N.O. 2 N.O. 3 N.O. 4 N.O.
ALARM RESET IN : N.O. BUZZER : ON KEY LOCK : OFF ALARM HOLD TIME: 05 SEC
CH1 - CH4 to set the sensor input type as
'N.O.' : normally open, closed will invoke alarm 'N.C.' : normally closed, open will invoke alarm 'closed' means to short the alarm signal line to the ground
9
ALARM RESET IN : To set alarm reset input type as 'N.O.' or 'N.C.' BUZZER : Turn the buzzer ON/OFF KEY LOCK : Turn the KEY LOCK function ON or OFF when key lock is turned on
1. All keys except SET key are locked
2. KEY LOCK stays ON until we turn it OFF by pressing the SET key
ALARM HOLD TIME : It is the time period of buzz if the buzzer is on.
10
Chapter II Back Panel Connection
VIDEO INPUT
1. BNC Connectors
1.1 MONITOR
Connect this output port to the main monitor.
1.2 VCR OUT
Connect this output port to the VIDEO IN of VCR. The quad video output of live video is obtained from this connector.
1.3 VCR IN
Connect this input port to the VIDEO OUT of VCR.
VCR
IN OUT OUT
MONITOR
AC24V
ALARM I/O
DC12V
1.4 VIDEO INPUT
Connect camera video out to this connector by a 75 ohm coaxial cable.
8
2. Alarm Connectors (DB-15)
15
PIN # NAME PIN # NAME 1 Alarm Out Common contact 9 Alarm Out Normally Open 2 Alarm Out Normally Closed 10 TXD * 3 Alarm Reset 11 RXD * 4 GROUND 5 ALARM IN 4 6 ALARM IN 3
1
9
7 ALARM IN 2 8 ALARM IN 1
2.1 Alarm out
There are two ways to do the alarm out connection:
2.1.1 Normally Open Connection (use pin # 1 and # 9)
11
8
2 1
Alarm out
15 9
EverPlex 4CQ
2.1.2 Normally Closed Connection (use pin # 1 and # 2)
8
Alarm out
15 9
2 1
RELAY
COIL
RELAY
COIL
EverPlex 4CQ
12
2.2 Alarm in and Alarm reset
There are 4 alarm sensors in for 4 channels and 1 alarm reset in, all these 5 alarm inputs can be set to Normally Open or Normally Closed by user and the setting menu.
SENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4
ALARM CIRCUIT
8
2 1
15
ALARM RESET
2.2.1 ALARM IN
There are four alarm inputs for each camera.
When any alarm signal happens, the machine will do the following:
1. Switch to the full screen display of this channel.
2. Blink the channel ID with alarm message.
3. Turn on the buzzer if the buzzer setting is on.
9
EverPlex 4CQ
When many alarms come up in the alarming status, the monitor screen will switch to quad display to show all the channels which have alarm in.
13
pp
N
p
y
The
ALARM IN
Normally Open
(N.O.)
can be selected as normally open input or normally closed input:
If the alarm input is selected as Normally Open input, then the
:
input is opened normally and shorted to the ground means an alarm happens.
Normally Closed
If the alarm input is selected as Normally Closed input, then the
:
(N.C.) input is shorted to the ground normally and opened means an alarm
ha
ens.
2.2.2 ALARM RESET
External alarm reset signal is used to reset the alarm and turn the buzzer off. If it is selected as Normally Closed input, then the input is shorted to the ground normally. Furthermore, it is opened when an alarm reset signal comes in. If it is selected as
ormally Open input, then the input is opened normally. Also it is shorted to the
ground when an alarm reset signal comes in
.
3. RS232 Connection
EverPlex 4CQ may be controlled by a computer or a terminal via the standard 9 pin D­sub/RS232 connector, which is connected to the alarm I/O by a cable with 15 pin and 9
in connectors. The Processor will send the alarm message to the host via RS232 when
an
alarm occurs.
VIDEO INPUT
VCR
IN OUT OUT
MONITOR
AC24V
ALARM I/O
DC12V
15-PIN MALE CONNECTOR
5
1
9-PIN FEMALE D-SUB CONNECTOR
69
14
p
3.1. The pin assignment of the 9 pin D-SUB connector
EverPlex 4CQ
PIN # NAME PIN # NAME 1 NOT CONNECTED 1 NOT CONNECTED 2 TXD 2 RXD 3 RXD 3 TXD 4 NOT CONNECTED 4 DTR 5 GROUND 5 GROUND 6 NOT CONNECTED 6 DSR 7 NOT CONNECTED 7 RTS 8 NOT CONNECTED 8 CTS 9 NOT CONNECTED 9 NOT CONNECTED
HOST
3.2. Transmission Setting
The transmission setting in the EverPlex 4CQ is 9600 baud rate, 1 start bit, 1 stop bit and no parity.
3.3. Remote control protocol
A computer or a terminal can be used to control the EverPlex 4CQ by sending two­character ASCII command through RS232 connector. These ASCII commands are started with 'K' or 'k'. There are 9 ASCII comm ands mapped to the 9 k eypads in the f ront
anel and 1 additional commands to reset the EverPlex 4CQ to the QUAD display state.
These 10 ASCII commands are show as below:
EverPlex 4CQ Remote Control Command Table
ASCII CODE FUNCTION Keypad in front panel
K1 Full Screen 1 K2 Full Screen 2 K3 Full Screen 3 K4 Full Screen 4 K5 Quad Display K6 Freeze K7 Sequential Switching Seq K8 VCR Play Back K9 SET
Freeze
Set
K0 Reset the Processor to Quad display None
3.4. Alarm message sent via RS232
The EverPlex 4CQ will send out alarm message thru RS232 when any alarm occurs, the alarm message format are three ASCII characters followed carriage return and line feed, they are
15
The first character is the leading code ,
'!'
The second character is the alarm type, 'S' indicates a sensor alarm, 'V' indicates a video loss The third character is the channel number having the alarm,
'1' ~ ’4'
The fourth byte is the carriage return code, 0DH The fifth byte is the line feed code, 0AH
EverFocus Electronics Corp.
Head Office: 10F-6, No.79 Sec. 1 Shin-Tai Wu Road,
Hsi-Chi, Taipei, Taiwan TEL: 886-2-26982334 FAX: 886-2-26982380
USA Office: 2445 Huntington Drive, San Marino, CA 91108, U.S.A. TEL: 1-626-844-8888 FAX: 1-626-844-8838 Toll free: 1-888-383-6287 or
1-888-EV-FOCUS
Hong Kong Office: Room 0, 10/F., Block 3, Camelpaint Building, 60, Hoi Yuen Road, Kwun Tong, Kowloon, Hong Kong Tel: 852-27589877 Fax: 852-27589056
European Office: Albert-Einstein-Strasse 1 D-46446 Emmerich, Germany TEL: 49-2822-9394-0 FAX: 49-2822-939495
P/N: M4CQG0020A
Loading...