Refrigeration System
· Bottom mounted, self-contained and fully detachable Blizzard R290 condensing unit uses environmentally
friendly, EPA-compliant R290 refrigerant with zero (0) Ozone Depletion Potential (ODP) and three (3) Global
Warming Potential (GWP). Blizzard R290 is easily replaceable and requires no on-site brazing.
· Front air intake and rear air discharge design allows side by side installation.
· Conforms to NSF Standard 7 TYPE ll (maximum ambient temperature 80°F).
· Electronically commutated (ECM) evaporator fan motors achieve rapid cooling with less energy consumption.
· High performance, auto-reverse condenser fan motor supports compressor ventilation and condenser coil
cleaning. Refer to owner's manual for full maintenance instructions.
· Large capacity, corrosion-resistant condenser and evaporator coils.
· Self-maintaining, energy-efficient condensate drain pan requires no external drains or electric heaters.
· Pre-wired and ready to plug, 115V/60Hz/1Ph, NEMA 5-20P.
Cabinet Construction
· Black or white modern exterior has moisture-resistant panels and field- replaceable tempered glass.
· Heavy-duty stainless steel interior has perforated back wall for efficient air flow. Includes floor drains for ease
of cleaning.
· Galvanized steel top, bottom and rear.
· 2.5" thick high-density polyurethane insulation.
· Integrated retractable night curtain saves energy and provides security.
· 5" swivel casters with locks on front set. Leg stabilizers standard for all models.
Lighting
· Shielded LED bar lighting under shelves and canopy provide bright, high color illumination at lower heat
output. On/off switch saves energy
Shelving
· Adjustable by height and angle. Position it flat or slanted downward at 10°.
· Heavy duty stainless steel shelves include price tag moldings.
Temperature Control
· Factory preset temperature of 35°F maintains a combined average product temperature of 40°F or less.
· Audible overheat protection alarm for compressor and condenser coil.
Recommended Operating Conditions
· Conforms to NSF standard 7 TYPE ll designed to operate in an air-conditioned environment where
temperature and humidity do not exceed 80°F and 55% relative humidity.
· Must not be installed near ventilation systems, fans or exterior doors or windows that will disrupt the air
curtain and compromise the function of the cabinet.
· Must not be installed in direct sunlight.
· In built-in applications, a distance of 6" is required on the front, back and top exterior for ventilation
purposes.