IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT: Read the assembly instruction section and safety precautions of this booklet
carefully before removing the contents of this carton.
1. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to insure that they do not play with the appliance.
2. In certain circumstances electrical appliances may be a danger hazard. The unit MUST be connected to the electrical supply before operation to enable the electronic ignition to work.
3. Do not place heavy objects on this appliance.
4. Damage can occur to bench tops if pots and pans are able to overlap the bench top. This can result in heat being transferred to the bench top. Ensure that correct sized pots & pans are used. Refer to guide in booklet.
5. Do not allow pot handles or utensils to be placed near gas burners which are operating, as they can cause the handles to become hot to touch. Always turn handles away when small children are nearby. It is recommended that children are kept away from the cooktop at all times.
6. If the electrical supply cord is damaged, either when being installed or after installation, it must be replaced by the manufacturer, it’s service agent or similarly qualified persons in order to prevent a hazard.
7. The electrical connection must be accessible after installation.
8. Electrical connection must be made as per local wiring rules and regulations.
9. Ensure that the kitchen is well ventilated or mechanical ventilation is in use while cooking on the gas cooktop.
10. Do not store or use flammable materials or aerosols near the cooktop.
11. WARNING - The cooktop will become hot during and directly after use. Do not touch any components during this time, as they may be hot and can cause burns.
12. Cleaning may only be commenced on the appliance once it has cooled down.
13. When the appliance is not being used, the knobs must be kept in the ‘OFF’ position.
14. Not to be used in a marine environment.
15. Where this appliance is installed in a caravan, it shall NOT be used as a space heater.
16. Do not modify this appliance.
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE DO NOT STORE CHEMICALS OR FLAMMABLE MATERIALS OR
DO NOT OPERATE THIS APPLIANCE BEFORE READING THE
INSTRUCTION BOOKLET
SPRAY AEROSOLS NEAR THIS APPLIANCE
DESIGNED TO PERFECTION
3
APPLIANCE DETAILS
Gas Type: ULPG NG Burner Pressure: 2.75 kPa 1.00 kPa
Injector Diameter: Auxiliary Burner Ø0.55 mm 4.0 MJ/ hr Ø0.90 mm 4.0 MJ/ hr Injector Diameter: Semi-Rapid Burners Ø0.70 mm 6.5 MJ/ hr Ø1.10 mm 6.2 MJ/ hr Injector Diameter: Rapid Burners Ø0.90 mm 11 MJ/ hr Ø1.40 mm 10 MJ/ hr Injector Diameter: Wok Burner Ø0.98 mm 13.2 MJ/ hr Ø1.70 mm 13.5 MJ/ hr
Note: The size of the injector diameter is stamped on the front face (e.g. 1.8 for Ø1.80mm injector).
Relevant Sizes: LENGTH (mm) WIDTH (mm) HEIGHT (mm) Hob size 580 500 80mm Cut-out size 555 473 -
Injector
Diameter
MJ/hr Rating
Injector
Diameter
MJ/hr Rating
Semi-rapid Burner Rapid Burner
Auxiliary Burner Wok Burner Semi-rapid Burner
Table of recommended pot sizes for each burner type:
Control Knob functions are displayed around each knob as shown below
Electrical: Value: Input Voltage: 220V to 240V @ 50Hz to 60Hz Maximum Current: 0.6A
BURNER TYPE DIAMETER OF POT (mm)
Auxiliary Burner Ø120 TO Ø140
Semi-Rapid Burners Ø140 TO Ø230
Rapid Burners Ø180 TO Ø260
Wok Burner Ø220 TO Ø260