Event electronic CO5120BN, CO5120PDBN User Manual

Page 1
1
THIS USER’S MANUAL HAS BEEN RESIZED TO PRINT OUT ON 8-1/2 x 11” PAGES.
BLACK page numbers reference the original printed document.
RED page numbers reference this web version.
Models CO5120BN, CO5120PDBN
M08-0002-000 Q 10/02
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
USER’S MANUAL
AC POWERED CARBON
MONOXIDE ALARM
WITH BATTERY BACK-UP
Model CO5120BN
AC POWERED CARBON
MONOXIDE ALARM
WITH BATTERY BACK-UP
AND DIGITAL DISPLAY
Model CO5120PDBN
120VAC ~, 60Hz, 0.09A
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
How Your CO Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Understanding the Light and Horn Patterns . . . . . . . . . . . . . . . . . . . .1-2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4/2-3
Where to Install CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where CO Alarms Should NOT Be Installed . . . . . . . . . . . . . . . . . . . . .2
How to Install Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4/3
Using the Optional Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . .3-4/4
The Battery Compartment Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/4
The Mounting Bracket Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
If Your CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
If the Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
The Latching Alarm Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Replacing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7/6
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Finding the Source of CO After an Alarm . . . . . . . . . . . . . . . . . . . . . . .6
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . . . .6
How Can I Protect My Family? . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7/6
Underwriters Laboratories, Inc. UL2034 . . . . . . . . . . . . . . . . . . . . . . . . .7/6
General Limitations Of CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7/7
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7/7
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7/7
All Rights Reserved. © 2002 BRK Brands, Inc. BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122 Consumer Affairs: (800) 323-9005 www.brkelectronics.com
INTRODUCTION
BASIC SAFETY INFORMATION
Dangers, Warnings, and Cautions alert you to important operating instructions or to potentially hazardous situations. Pay special attention to these items.
THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect carbon monoxide from ANY source of combustion. It is NOT designed to detect smoke, fire, or any other gas.
This CO Alarm is approved for use in single-family residences. It is NOT designed for marine or RV use.
This CO Alarm will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas.
This unit does not work without power. If the AC power fails, the battery back-up will power the alarm for at least 7 days provided the 9V battery is fresh and correctly installed.
The Silence Feature is for your convenience only and will not correct a CO problem. Always check your home for a potential problem after any alarm. Failure to do so can result in injury or death.
This CO Alarm should receive continuous 120VAC, 60 Hz, pure sine wave electrical power. (The battery is meant for emergency back-up only). Do not use in an extension cord or outlet controlled by a dimmer or switch. In order for the emergency battery back-up to work, a working (fresh) bat­tery must be properly installed.
NEVER ignore any alarm. See If Your CO Alarm Sounds for more information on how to respond to an alarm. Failure to respond can result in injury or death.
Test this Carbon Monoxide Alarm once a week. If it ever fails to test correctly, have it replaced immediately! If the CO Alarm is not working properly, it cannot alert you to a problem.
This product is intended for use in ordinary indoor locations of family living units. It is not designed to measure CO levels in compliance with Occupational Safety and Health Administration (OSHA) commercial or industrial standards. Individuals with medical conditions that may make them more sensitive to carbon monoxide may consider using warning devices which provide audible and visu­al signals for carbon monoxide concentrations under 30 ppm. For additional information on carbon monoxide and your medical condition contact your physician.
HOW YOUR CO ALARM WORKS
The Cover Of Your CO Alarm
1. Test/Silence Button Scroll Button (CO5120PDBN)
2. POWER/ALARM Light (RED)
3. Air Vents
4. (Behind the Cover) Alarm Horn: 85dB audible alarm for test, alarm, and unit malfunction warning.
5. Digital Display (CO5120PDBN)
UNDERSTANDING THE LIGHT AND HORN PATTERNS (CO5120BN)
Condition LED (Red Light) Horn
POWER UP LED flashes on once, Horn chirps
then shines continuously once.
DURING TESTING LED flashes once every second Horn pattern:
during the test cycle 4 beeps, pause,
4 beeps, pause
LOW OR MISSING LED flashes once a minute Horn chirps BATTERY once a minute
MISSING OR DEAD LED is OFF Horn is silent BATTERY (DC back­up disabled
WARNING: When the AC power is Off, if the battery is dead or missing, the CO Alarm cannot work.
2
1
5
3
4
Page 2
2
UNDERSTANDING THE LIGHT AND HORN PATTERNS (CO5120BN), Continued
Condition LED (Red Light) Horn
ALARM CONDITION LED flashes once every second Horn pattern: Single CO Alarm 4 beeps, pause, (not interconnected) 4 beeps, pause,
repeating
ALARM CONDITION LED flashes rapidly on the units Horn pattern: Interconnected that triggered the alarm. LEDs 4 beeps, pause, Series of CO Alarms on the other Alarms in the series repeating on all
will not flash CO Alarms
IN SILENCE MODE LED flashes once every second Horn stays quiet
on initiating Alarm for 4 minutes
LATCHING ALARM LED Flashes once every Horn stays quiet INDICATOR 5 seconds
MALFUNCTION LED flashes 3 times Horn sounds
synchronized with 3 rapid chirps 3 rapid chirps
(chirp-chirp-chirp) every minute
DISPLAY CONDITIONS (CO5120PDBN)
Alarm operating on AC power
Alarm operating on emergency battery back-up
Low / missing battery warning
Err Alarm is not operating properly
What you see and hear if CO is detected:
PRE-ALARM LEVELS :
HORN:
Silent
DISPLAY: Shows CO levels detected in ppm (CO5120PDBN)
POWER/ALARM LIGHT: On continuously
ALARM LEVELS OF CO ARE DETECTED:
HORN:
Sounds loudly - 4 beeps, pause, 4 beeps, pause. This sequence repeats for as long as the unit is in alarm*
DISPLAY: Shows CO levels detected in ppm (CO5120PDBN)
POWER/ALARM LIGHT: Flashes rapidly *Note: If unit goes into alarm under battery back-
up power, the regular 4 beeps-brief pause cycle will repeat for four minutes. After four minutes, the pause will increase to 1 minute.
IF YOU SILENCE THE ALARM:
HORN:
Silent for about 4 minutes*
DISPLAY: Shows CO levels detected in ppm (CO5120PDBN)
POWER/ALARM LIGHT: Flashes rapidly *Note: After 4 minutes, if CO levels drop below
alarm levels, the unit will remain silent and return to normal operation. If CO present still indicates a potentially dangerous situation, the horn will sound again.
IF THE CO LEVELS RETURN TO NORMAL:
HORN:
Silent
DISPLAY: Dash lit by READY (CO5120PDBN) POWER/ALARM LIGHT: Shines continuously
SMART INTERCONNECT FEATURE
This CO Alarm includes Smart Interconnect which enables the Alarm to be interconnected with other BRK Smoke and CO Alarms. When interconnected to Smoke Alarms that go into alarm, this CO Alarm will sound the smoke horn pattern.
USING THE PEAK CO MEMORY (CO5120PDBN)
The CO Memory Feature lets you check the highest level of CO recorded during an alarm.
To check CO Memory:
1. Press and release the Test/Silence/Scroll button until the dash scrolls to MEMORY”.
2. Press and hold Test/Silence/Scroll button to display Memory CO level.
To clear CO Memory:
1. Press and release the Test/Silence/Scroll button until the dash scrolls to CLEAR MEMORY.
2. Press and hold the Test/Silence/Scroll button until the display shows CLr. NOTE: The highest CO level will be saved, even after a power interruption, until you clear it. DO NOT clear the
CO Memory reading if you plan to call someone to investigate a CO problem! Clear the CO Memory reading only after the investigator has checked your home.
INSTALLATION
WHERE TO INSTALL CO ALARMS
The National Fire Protection Association (NFPA) recommends that a CO Alarm should be centrally located out­side of each separate sleeping area in the immediate vicinity of the bedrooms. For added protection, install additional CO Alarms in each separate bedroom, and on every level of your home.
If your bedroom hallway is longer than 40 feet (12 meters), install a CO Alarm at BOTH ends of the hallway.
In a Single-level Home:
Install at least one CO Alarm near or within each separate sleeping area.
For added protection, install an additional CO Alarm at least 20 feet (6 meters), away from the furnace or fuel burning heat source.
In a Multi-level Home–(same as above plus):
Install at least one CO Alarm near or within each separate sleeping area.
For added protection, install at least one CO Alarm on each level of the home. If you have a basement,
install that CO Alarm at the top of the basement stairs.
For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.
WHERE CO ALARMS SHOULD NOT BE INSTALLED
DO NOT locate this CO Alarm:
In garages, kitchens, furnace rooms, or in any extremely dusty, dirty or greasy areas.
Where combustion particles are produced. Combustion particles form when something burns. Areas to
avoid include poorly ventilated kitchens, garages, and furnace rooms. Keep units at least 20 feet (6 meters) from the sources of combustion particles (stove, furnace, water heater, space heater) if possible. In areas where a 20-foot distance is not possible – in modular, mobile, or smaller homes, for example – it is recom­mended the CO Alarm be placed as far from these fuel-burning sources as possible. The placement recom­mendations are intended to keep these Alarms at a reasonable distance from a fuel-burning source, and thus reduce “unwanted” or “nuisance” alarms. Unwanted alarms can occur if a CO Alarm is placed directly next to a fuel-burning source. Ventilate these areas as much as possible.
Within 5 feet (1.5 meter) of any cooking appliance.
In extremely humid areas. This Alarm should be at least 10 feet (3 meter) from a bath or shower, sauna,
humidifier, vaporizer, dishwasher, laundry room, utility room or other source of high humidity.
In areas where temperature is colder than 40˚F (4˚C) or hotter than 100˚F (38˚C). These areas include non­airconditioned crawl spaces, unfinished attics, uninsulated or poorly insulated ceilings, porches, and garages.
In turbulent air, like near ceiling fans, heat vents, air conditioners, fresh air returns, or open windows. Blowing air may prevent CO from reaching the sensors.
In direct sunlight.
This CO Alarm is designed for use inside a single-family home or apartment. It is not meant to be
used in common lobbies, hallways, or basements of multi-family buildings unless working CO Alarms are also installed in each family living unit. CO Alarms in common areas may not be heard from inside individual family living units.
This CO Alarm alone is not a suitable substitute for complete detection systems in places which
house many people, like hotels or dormitories, unless a CO Alarm is also placed in each unit.
DO NOT use this CO Alarm in warehouses, industrial or commercial buildings, special-purpose
non-residential buildings, RVs, boats, or airplanes. This CO Alarm is specifically designed for residential use, and may not provide adequate protection in non-residential applications.
BEDROOM
GARAGE
HALL
BASEMENT
BEDROOM
KITCHEN
BEDROOM
LIVING ROOM
REQUIRED TO MEET NFPA RECOMMENDATIONS
SUGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS
Page 3
3
BEFORE YOU BEGIN INSTALLATION
This unit is designed to be mounted on any standard wiring junction box up to a 4-inch size, on either the ceil­ing or wall. Read Where to Install CO Alarms and Where Not To Install CO Alarms before you begin installa­tion. If a junction box is not already in place, install one using standard #12 or #14 gauge copper wire.
This Alarm must have AC or battery power to operate. If the AC power fails, the battery back-up will power the Alarm for a short time if the 9V battery is fresh and correctly installed. If AC power fails, and the battery is dead or missing, the Alarm cannot operate.
Find the pair of self-adhesive labels included with this CO Alarm.
On each label write in the phone number of your emergency responder (like 911) and a qualified appliance technician.
Place one label near the CO Alarm, and the other label in the fresh air location you plan to go if the alarm sounds.
NOTE: A qualified appliance technician is defined as a person, firm, corporation, or company that either in person or through a representative, is engaged in and responsible for the installation, testing, servicing, or replacement of heating, ventilation, air conditioning (HVAC) equipment, combustion appliances and equipment, and/or gas fire­places or other decorative combustion equipment.
PARTS OF THIS CO ALARM
1 Mounting Bracket
2 Mounting Slot and Screw*
3 Locking Pins (break out of
bracket)
4 Hot (Black) AC Wire
5 Neutral (White) AC Wire
6 Interconnect Wire (Orange)
7 Lever to Open Battery
Compartment
8 Swing-Out Battery
Compartment
9 Quick-Connect Power
*Not Included
HOW TO INSTALL YOUR CO ALARM
INSTALLATION, continued
Tools you will need: Standard/Flathead screwdriver.
ELECTRICAL SHOCK HAZARD. Turn off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation. Failure to turn off the power before installation may result in serious electrical shock, injury or death.
To install this unit:
1. Remove the mounting bracket from the base. Position the screw slots on the mounting bracket over the screws in the junction box. Tighten the screws.
2. Using wire nuts, connect the power connector to the AC power.
3. Plug the power connector into the back of the CO Alarm.
4. Position the base of the Alarm over the mounting bracket and turn. The Alarm can be positioned over the bracket every 60°. Turn the unit clockwise (right) until the unit is in place.
5. Check all connections.
STAND ALONE ALARM ONLY:
Connect the white wire on the power connector to the neutral wire in the junction box.
Connect the black wire on the power connector to the hot wire in the junction box.
Tuck the orange wire inside the junction box.
It is used for interconnect only.
INTERCONNECTED ALARMS ONLY: Strip off about 1/2 of the plastic coating on the orange interconnect wire on the power connector.
Connect the white wire on the power connector to the neutral wire (usually white) in the junction box.
Connect the black wire on the power connector to the hot wire (usually black) in the junction box.
Connect the orange wire on the power connector to the interconnect wire in the junction box. Repeat for
each unit you are interconnecting. Never connect the hot or neutral wires in the junction box to the orange interconnect wire.
STAND ALONE ALARM ONLY:
If you are only installing one unit, restore power to the junction box.
INTERCONNECTED ALARMS ONLY:
If you are interconnecting multiple Alarms, repeat Step 1-5 for each Alarm in the series. When you are finished, restore power to the junction box.
ELECTRICAL SHOCK HAZARD. Do not restore power until all Alarms are completely installed. Restoring power before installation is complete may result in serious electrical shock, injury or death.
SPECIAL REQUIREMENTS FOR INTERCONNECTED CO ALARMS
Failure to meet any of the above requirements could damage the units and cause them to mal­function, removing your protection.
AC and AC/DC CO Alarms can be interconnected. Under AC power, all units will alarm when one senses CO. When power is interrupted, only the AC/DC units in the series will continue to send and receive signals. AC powered CO Alarms will not operate.
Interconnected units can provide earlier warning of a CO problem than stand-alone units, especially if the prob­lem starts in a remote area of the dwelling. If any unit in the series senses CO, all units will alarm. To determine which CO Alarm initiated an alarm, refer to the table.
On Initiating CO Alarm Red LED Flashes Once per Second
On All Other CO Alarms Red LED Does Not Flash Once per Second
Interconnect units within a single family residence only. Otherwise all households will experience unwanted alarms when you test any unit in the series. Interconnected units will only work if they are wired to compatible units and all requirements are met.
This unit is designed to be compatible with: BRK Electronics®Smoke Alarm Models SC6120B, 4120, 4120B, 4120SB, 4919, 2002RAC, 100S, 5919, 5919TH; BRK Electronics®Heat Alarm Models HD6135F, HD6135FB; BRK Electronics®CO Alarm Models SC6120B, CO5120BN, CO5120PDBN; and
First Alert®Smoke Alarm Models SA4120B, SA4121B, SA4919B, SA100B.
Interconnected units must meet ALL of the following requirements:
A maximum of 18 compatible BRK Electronics® Smoke, Heat or CO Alarms may be interconnected. No more than 12 of the 18 can be Smoke Alarms per NFPA 72.
The same fuse or circuit breaker must power all interconnected units.
The total length of wire interconnecting the units should be less than 1000 feet. The interconnect wire
should be Type 18 gauge AWM or larger, rated at least 300V. If an interconnect wire is not already part of your household wiring, you will need to install one. This type of wire is commonly available at Hardware and Electrical Supply stores.
All wiring must conform to all local electrical codes and Article 760 of the National Electrical Code. Refer to NFPA, Chapter 2 and/or your local building code for further connection requirements.
6.
Make sure the CO Alarm is receiving AC power. Under normal operation,the red indicator light will shine continu­ously.
If the red power indicator light does not light, TURN OFF POWER TO THE JUNCTION BOX and recheck all connections. If all connections are correct and the red power indicator still does not light when you restore the power, the unit should be replaced immediately.
7.
ACTIVATING THE BATTERY BACK-UP
Activate the battery back-up by removing the Pull to Activate Battery Back-Up tab. You do not need to open the battery compartment and reposition the battery during installation.
DO NOT remove the battery
activation tab until AC power is turned on to conserve battery power.
8. Test the CO Alarm. Press and hold the test button on the cover until the alarm sounds: 4 beeps, pause, 4 beeps, pause. In a series of interconnected Alarms, you must test each Alarm separately by pressing and holding the test button. Make sure all units alarm when each one is tested.
If any unit in the series does not alarm during testing, TURN OFF POWER and recheck connections. If it does not alarm when you restore power, replace it immediately.
A. Unswitched 120VAC 60 Hz source B. To Additional Alarms, Maximum = 18 Alarms
1. CO Alarm
2. Ceiling or Wall
3. Power Connector
4. Wire Nut
5. Junction Box
6. Neutral Wire (White)
7. Interconnect Wire (Orange)
8. Hot Wire (Black)
2
3
7
8
1
4
5
3
2
6
9
6
A
}
7
}
8
B
5
4 3 2
1
5 4 3
1
Page 4
4
The optional locking features are designed to prevent unauthorized removal of the battery or alarm. It is not necessary to activate the locks in single-family households where unauthorized battery or alarm removal is not a concern.
These CO Alarms have two separate locking features: one locks the battery compartment, and the other locks the CO Alarm to the mounting bracket. You can choose to use either feature independently, or use them both.
Tools you will need: Needle-nose pliers Standard/Flathead screwdriver. Both locking features use locking pins, molded into the mounting bracket. Using needle nose pliers or a utility knife, remove one or both pins,
depending on which locking features you use.
USING THE OPTIONAL LOCKING FEATURES
THE BATTERY COMPARTMENT LOCK:
TO LOCK THE BATTERY COMPARTMENT:
Do not lock the battery compartment until you have activated the battery and tested the battery back-up.
1. Activate the battery back-up by removing the Pull to Activate Battery Back­Up tab. Push and hold the test button on the CO Alarms cover until
you
hear an acknowledge chirp and
the alarm sounds: 4 beeps, pause, 4 beeps,
pause.
If the unit does not alarm during testing, DO NOT lock the battery com­partment! Install a new battery and test again. If it still does not alarm, replace the CO Alarm immediately.
2. Using needle-nose pliers or a utility knife, detach one locking pin from the mounting bracket.
3. Push the locking pin through the black dot on the label on the back of the CO Alarm.
TO UNLOCK THE BATTERY COMPARTMENT:
Once the CO Alarm is installed, you must disconnect it from the AC power before unlocking the battery compartment.
ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the CO Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electrical shock, injury or death.
Always discharge the branch circuit before servicing an AC or AC/DC CO Alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from Alarms with battery back-up. Finally, press and hold the test button for 5-10 seconds to discharge the branch circuit.
1. Remove the CO Alarm from the mounting bracket. If the unit is locked to the bracket, see the section To Deactivate the Locking Feature.
2. Disconnect the power connector by gently prying it away from the back of the CO Alarm.
3. Insert a flathead screwdriver under the head of the locking pin, and gently pry it out of the battery compartment lock. (If you plan to re-lock the bat­tery compartment, save the locking pin.)
4. To re-lock the battery compartment, close the battery door and reinsert the locking pin in the lock.
5. Reconnect the power connector to the back of the CO Alarm, reattach the CO Alarm to the mounting bracket, and restore the power.
When replacing the battery, always test the CO Alarm before re-locking the battery compartment.
THE MOUNTING BRACKET LOCK
Tools you will need:
Needle-nose pliers
Standard/Flathead screwdriver
TO ACTIVATE THE BRACKET LOCK:
1. Using needle-nose pliers, detach one locking pin from the mounting bracket.
2. Insert the locking pin into the lock located on the pivoting hinge of the battery door.
3. When you attach the CO Alarm to the mounting bracket, the locking pins head will fit into a notch on the bracket.
TO DEACTIVATE THE BRACKET LOCK:
ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the CO Alarm is installed before removing it from the mounting bracket. Failure to turn off the power first may result in serious electri­cal shock, injury or death.
Always discharge the branch circuit before servicing an AC or AC/DC CO Alarm. First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery from Alarms with battery back-up. Finally, press and hold the test button.
1.
Insert a flathead screwdriver between the mounting bracket pin and the mounting bracket.
2. Pry the CO Alarm away from the bracket by turning both the screwdriver and the CO Alarm counterclockwise (left) at the same time.
TO PERMANENTLY REMOVE THE BRACKET LOCK:
Insert the flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.
Locking Pin
Page 5
5
IF YOUR CO ALARM SOUNDS
Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. When your CO Alarm sounds, you must not ignore it!
IF THE ALARM SOUNDS:
1.
Operate the Test/Silence button to silence the alarm.
2. Call your emergency services, fire department or 911. Write down the number of your local emergency serv­ice here:
________________________________________________________________
3. Immediately move to fresh airoutdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re-enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.
4.
After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a quali­fied appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection have the equip­ment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adja­cent to the residence. Write down the number of a qualified appliance technician here:
__________________________
_______________________________________
USING THE SILENCE FEATURE
NEVER disconnect the power to your CO Alarm to silence the hornuse the silence feature. Disconnecting the CO Alarm removes your protection! See previous page for details on responding to an alarm.
The Silence Feature is intended to temporarily silence your CO Alarm’s alarm horn while you correct the prob- lemit will not correct a CO problem. While the Alarm is silenced, it will continue to monitor the air for CO.
When CO reaches alarm level, the unit will sound repeating horn pattern: 4 beeps, a pause, 4 beeps, etc. Press and hold the Test/Silence button until the horn is silent. The Silence cycle will last approximately 4 minutes.
To silence an interconnected series of Alarms, you must press the Test/Silence button on the initiating alarm (the unit with the flashing red light). If you press the Test/Silence on any other Alarm, it will only silence that unit, not the whole interconnected series.
NOTE: After the 4-minute silence cycle, the CO Alarm re-evaluates present CO levels and responds accordingly. If
CO levels remain potentially dangerousor start rising higherthe horn will start sounding again.
While the CO Alarm is silenced:
If the CO Alarm...is silent for only 4 minutes, then starts sounding loudly4 beeps, then a pause, 4 beeps, then a
pause. Red light (LED) continues flashing...
This means...CO levels are still potentially dangerous.
If the CO Alarm...remains silent....
This means...unit has returned to normal operation.
SILENCING THE LOW BATTERY WARNING
This silence feature can temporarily quiet the low battery warning chirp for up to 8 hours if AC power is pres­ent. Press the Test/Silence button on the alarm cover. Once the low battery warning chirp silence feature is activated, the unit continues to flash the red light once a minute for 8 hours. After 8 hours, the low battery chirp will resume. Replace the battery as soon as possible, to maintain protection in the event of a power outage.
THE LATCHING ALARM INDICATOR:
The Latching Alarm Indicator is activated after a CO Alarm is exposed to alarm levels of carbon monoxide. After CO levels drop below alarm levels, the red LED will begin to flash once every 5 seconds. It will continue to flash or latch until you clear it by testing the alarm.
This feature helps emergency responders, investigators, or service technicians identify which unit(s) in your home were exposed to alarm levels of carbon monoxide. This can help investigators pinpoint the source of CO.
Interconnected Alarms. Latching Alarm Indicator shows which Alarm(s) in the series were exposed to alarm levels of carbon monoxide.
The Latching Alarm Indicator stays ON until you clear it, so it can alert you to a CO Alarm that occurred while you were away from home, even though CO present in the air has dropped below alarm levels.
WEEKLY TESTING
Push and hold the Test/Silence button until you hear an acknowledge chirp and a loud alarm sounds 4 beeps, pause, 4 beeps. This sequence should last for 10 seconds. If the Alarm ever fails to test properly, replace it immedi­ately. If the Alarm is not working properly, refer to Limited Warranty”.
If the Alarm ever fails to test properly, replace it immediately. Products under warranty may be returned to the manufacturer for replacement. See Limited Warranty at the end of this manual.
DO NOT stand close to the Alarm when the horn is sounding. Exposure at close range may be harm­ful to your hearing. When testing, step away when horn starts sounding.
NEVER use vehicle exhaust! Exhaust may cause permanent damage and voids your warranty.
REGULAR MAINTENANCE
To keep the CO Alarm working properly:
Test it every week as described in “Weekly Testing.”
Vacuum the CO Alarm cover at least once a month, using the soft brush attachment. Never use water,
cleaners, or solvents, since they may damage the unit. Test the Alarm again after vacuuming.
Replace the battery immediately when you see/hear the Low Battery Warning.
The Low (or Missing) Battery Warning (CO5120PDBN):
The horn will chirp once a minute and the word bat will flash on and off on the display.
REPLACING THE BATTERY
Choosing a replacement battery:
This unit requires one standard 9V alkaline battery. The following alkaline bat­teries are acceptable as replacements: Duracell #MN1604 or MX1604; Eveready Energizer 522. You can also use an Ultralife 9 volt lithium battery #U9VL for longer service life between battery changes. These replacement batteries are commonly available at local retail stores.
Use only the alkaline or lithium replacement batteries listed. The unit may not operate properly with other batter­ies. Never use rechargeable batteries since they may not provide a constant charge.
DO NOT spray cleaning chemicals or insect sprays directly on or near the CO Alarm. DO NOT paint over the CO Alarm. Doing so may cause permanent damage.
Household cleaners, aerosol chemicals and other contaminants can affect the sensor. When using any of these materials near the CO Alarm, make sure the room is well ventilated.
If your home is being fumigated, unplug the unit temporarily and put it where it will not be exposed to
chemicals or fumes. When fumigation is complete and all traces of fumes clear, plug the unit back in and retest it.
KEY:
LATCHING ALARM: Unit was exposed
BEDROOM
LIVING ROOM
HALL
BASEMENT
BEDROOM
KITCHEN
BEDROOM
GARAGE
to alarm levels of CO
LATCHING NOT ACTIVATED: Unit was not exposed to alarm levels of CO
Page 6
6
WHAT YOU NEED TO KNOW ABOUT CO
WHAT IS CO?
CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to heat (usually fire). Electrical appliances typically do not produce CO.
These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane. Common appliances are often sources of CO. If they are not properly maintained, are improperly ventilated, or
malfunction, CO levels can rise quickly. CO is a real danger now that homes are more energy efficient. Air­tight homes with added insulation, sealed windows, and other weatherproofing can trap CO inside.
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be discussed with ALL household members.
Mild Exposure: Slight headache, nausea, vomiting, fatigue (flu-like symptoms). Medium Exposure: Throbbing headache, drowsiness, confusion, fast heart rate. Extreme Exposure: Convulsions, unconsciousness, heart and lung failure. Exposure to Carbon Monoxide can
cause brain damage, death.
This CO Alarm measures exposure to CO over time. It alarms if CO levels are extremely high in a short period of time, or if CO levels reach a certain minimum over a long period of time. The CO Alarm generally sounds an alarm before the onset of symptoms in average, healthy adults.
Why is this important? Because you need to be warned of a potential CO problem while you can still react in time. In many reported cases of CO exposure, victims may be aware that they are not feeling well, but become disorient­ed and can no longer react well enough to exit the building or get help. Also, young children and pets may be the first affected. The average healthy adult might not feel any symptoms when the CO Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. If you experience even mild symptoms of CO poisoning, consult your doctor immediately!
FINDING THE SOURCE OF CO AFTER AN ALARM
Carbon monoxide is an odorless, invisible gas, which often makes it difficult to locate the source of CO after an alarm. These are a few of the factors that can make it difficult to locate sources of CO:
House well ventilated before the investigator arrives.
Problem caused by backdrafting.
Transient CO problem caused by special circumstances.
Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO.
BRK Brands, Inc. shall not be obligated to pay for any carbon monoxide investigation or service call.
POTENTIAL SOURCES OF CO IN THE HOME
Fuel-burning appliances like: portable heater, gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer.
Damaged or insufficient venting: corroded or disconnected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked or clogged chimney opening.
Improper use of appliance/device: operating a barbecue grill or vehicle in an enclosed area (like a garage or screened porch).
Transient CO Problems: “transient or on-again-off-again CO problems can be caused by outdoor conditions and other special circumstances.
The following conditions can result in transient CO situations:
1. Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:
Wind direction and/or velocity, including high, gusty winds. Heavy air in the vent pipes (cold/humid air with extended periods between cycles).
Negative pressure differential resulting from the use of exhaust fans.
Several appliances running at the same time competing for limited fresh air.
Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.
Obstructions in or unconventional vent pipe designs which can amplify the above situations.
2.
Extended operation of unvented fuel burning devices (range, oven, fireplace).
3. Temperature inversions, which can trap exhaust close to the ground.
4. Car idling in an open or closed attached garage, or near a home. These conditions are dangerous because they can trap exhaust in your home. Since these conditions can come
and go, they are also hard to recreate during a CO investigation.
HOW CAN I PROTECT MY FAMILY?
A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening for average, healthy adults.
A CO Alarm is not a substitute for proper maintenance of home appliances.
To help prevent CO problems and reduce the risk of CO poisoning:
Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for proper air flow. Also, have a professional check for rust and corrosion, cracks, or separations. These conditions can prevent proper air movement and cause backdrafting. Never cap or cover a chimney in any way that would block air flow.
Test and maintain all fuel-burning equipment annually. Many local gas or oil companies and HVAC companies offer appliance inspections for a nominal fee.
Make regular visual inspections of all fuel-burning appliances. Check appliances for excessive rust and scaling. Also check the flame on the burner and pilot lights. The flame should be blue. A yellow flame means fuel is not being burned completely and CO may be present. Keep the blower door on the furnace closed. Use vents or fans when they are available on all fuel-burning appliances. Make sure appliances are vented to the outside. Do not use grills or barbecue indoors, or in garages or on screen porches.
Check for exhaust backflow from CO sources. Check the draft hood on an operating furnace for a backdraft. Look for cracks on furnace heat exchangers.
Check the house or garage on the other side of shared wall.
Keep windows and doors open slightly. If you suspect that CO is escaping into your home, open a
window or a door. Opening windows and doors can significantly decrease CO levels.
UNDERWRITERS LABORATORIES INC. UL2034
WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when exposed to lev­els of CO and exposure times as described below. They are measured in parts per million (ppm) of CO over time (in minutes).
UL2034 Required Alarm Points*:
If the Alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES
If the Alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.
If the Alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES.
* Approximately 10% COHb exposure at levels of 15% to 95% Relative Humidity (RH).
The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.
CO Alarms are designed to alarm before there is an immediate life threat. Since you cannot see or smell CO, never assume its not present.
An exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4 hours the same level may cause headaches.
An exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes, but can cause death after 2 hours.
Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon monoxide alarms UL2034.
According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. CO Alarms are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the dangers of Carbon Monoxide exposure. This CO Alarm monitors the air at the Alarm, and is designed to alarm before CO levels become life threatening. This allows you precious time to leave the house and correct the problem. This is only possible if Alarms are located, installed, and maintained as described in this manual.
Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.
Audible Alarm: 85dB minimum at 10 feet.
Page 7
7
This CO Alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for carbon monoxide detectors must be met.
CO Alarms will not work without power.
This CO Alarm requires a continuous supply of AC power, and a fresh,
correctly installed 9V battery to power the battery back-up. The battery back-up is for emergency use only!
CO Alarms for Solar or Wind Energy users and battery backup power systems: AC powered CO Alarms should only be operated with true or pure sine wave inverters. Operating this CO Alarm with most battery-pow­ered UPS (uninterruptible power supply) products or square wave or quasi sine wave inverters will damage
the Alarm. If you are not sure about your inverter or UPS type, please consult with the manufacturer to verify. This CO Alarm will not sense carbon monoxide that does not reach the sensor. This CO Alarm will only sense
CO at the sensor. CO may be present in other areas. Doors or other obstructions may affect the rate at which CO reaches the CO Alarm. For this reason, if bedroom doors are usually closed at night, we recommend you install a CO Alarm in each bedroom and in the hallway between them.
CO Alarms may not sense CO on another level of the home. For example, a CO Alarm on the second level, near the bedrooms, may not sense CO in the basement. For this reason, one CO Alarm may not give adequate warning. Complete coverage is recommended. Place CO Alarms on each level of the home.
CO Alarms may not be heard. The Alarm horn loudness meets or exceeds current UL standards of 85 dB at 10 feet. However, if the CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. This is especially true if the door is closed or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also prevent alert persons from hearing the alarm horn. This CO Alarm is not intended for people who are hear­ing impaired.
CO Alarms are not a substitute for a smoke alarm. Although fire is a source of carbon monoxide, this CO Alarm does not sense smoke or fire. This CO Alarm senses CO that may be escaping unnoticed from malfunc­tioning furnaces, appliances, or other sources. Early warning of fire requires the installation of smoke alarms.
CO Alarms are not a substitute for life insurance. Though these CO Alarms warn against increasing CO lev­els, BRK Brands, Inc. does not warrant or imply in any way that they will protect lives from CO poisoning. Homeowners and renters must still insure their lives.
CO Alarms have a limited life. Although the CO Alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail at any time. Therefore, you must test your CO Alarm weekly.
CO Alarms are not foolproof. Like all other electronic devices, CO Alarms have limitations. They can only detect CO that reaches their sensors. They may not give early warning to rising CO levels if the CO is coming from a remote part of the home, away from the CO Alarm.
GENERAL LIMITATIONS OF CO ALARMS
TROUBLESHOOTING GUIDE
Problem... If the Alarm.. You should...
Red light is OFF. Unit will not alarm when you press the Test/Silence button.
Unit may not be receiving any power. Check the AC power supply. Make sure the power
connector is securely attached to the Alarm. Make sure a fresh 9V battery is installed to power the battery back-up.
Red light flashes once a minute (horn is silent). (CO5120PDBN display reads bat).
Alarm is not receiving AC power. Unit is operating on DC battery back-up. Check the
AC power supply.
Once a minute, the red light flashes and the horn chirps. (CO5120PDBN display flashes bat).
Low battery warning. Replace the 9V battery in the battery back-up.
Disconnect AC power before changing the battery.
Once a minute, the alarm sounds 3 quick chirps”, and the red light flashes quickly three times. (CO5120PDBN display reads “Err”).
Based on its Self Test diagnostics, the unit has detected a malfunction. The unit needs to be replaced.
Make sure a fresh 9V battery is installed. If unit still isnt functioning– REPLACE IT. Units under warranty should be returned to manufacturer for replacement. See Limited Warranty for details.
CO Alarm sounds frequently even though no high levels of CO are revealed in an investigation.
The CO Alarm may be improperly located. Refer to Where to Install CO Alarms.
Relocate your Alarm. If frequent alarms continue, have home rechecked for potential CO problems. You may be experiencing an intermittent CO problem.
CO Alarm goes back into alarm 4 minutes after you press the Test/Silence button.
CO levels are still potentially dangerous. Refer to If Your CO Alarm Sounds for details on
how to respond to an alarm. If anyone is feeling ill, EVACUATE your home immediately and call 911.
ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the CO Alarm is installed BEFORE removing it from the mounting bracket or checking any electrical connections! Failure to turn off the power first may result in serious electrical shock, injury or death.
The following guide can help you identify a potential problem with the installation or operation of your CO Alarm.
NOTE:
It is not meant to be an all-
inclusive list of all CO Alarm conditions. If you are experiencing a condition
not covered in the next several pages, please contact Consumer Affairs.
LIMITED WARRANTY
BRK Brands, Inc., ("BRK") the maker of BRK Electronics®brand products warrants that for a period of five years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the prod­uct is no longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transfer­able. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. BRK deal­ers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the war­ranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.
BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.
How to Obtain Warranty Service Service:
If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you, please have the model number and date of purchase available when calling. 3920 Enterprise Court, Aurora, IL 60504-8132.