3. If odour continues, immediately call your gas supplier.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury
or property damage. Read the installation, operating and maintenance instructions thoroughly before
installing or servicing this equipment.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapours and liquids in the
vicinity of this or any other appliance. An LP cylinder not connected for use shall not be stored in the
vicinity of this or any other appliance.
*FOR OUTDOOR USE ONLY: The evenGLO® heater has been approved for indoor use in nonresidential applications. (See page 8 for details) for natural gas units ONLY!
: The installer or seller must leave these instructions with the owner. Only those who are
certified to do so should perform service on these heaters.
Please retain these instructions for future reference.
563 Barton Street
Stoney Creek ON L8E 5S1 Canada
www.irenergy.ca
October-28-15
Table Of Contents
CAUTION AND GENERAL SAFETY ............................................................................................... 3
Portable models # GA301 & GA301 - T ............................................................................................................ 10
Floor mount models # GA301- H ...................................................................................................................... 11
Hanging model # GA301- M & GA301 - MP ..................................................................................................... 12
At all times maintain clearance to combustible materials as further specified in this
manual. Failure to do so can result in serious fire hazard.
•
Never operate heaters in atmosphere containing flammable vapours or
combustible dusts.
•
This heater is equipped with an electronic and automatic ignition device. Do not
attempt to light the burner by hand. Failure to comply can result in a serious fire
and personal injury hazard.
•
Certain materials, when stored under this heater are subjected to radiant heat can
soften, distort or otherwise be damaged, special care should be taken of plastic
materials
•
Appliance surfaces, other than the obvious flame and emitter surfaces, attain
elevated temperatures during operation. Do not touch the heater head during
operation. Everyone should be alerted to this hazard to avoid burning.
•
Children should be strictly supervised when in the area of this heating appliance.
Playing or running around the structure should be strictly forbidden.
•
Clothing or other flammable materials should not be hung on or near this heater.
1. Heater anchoring hardware for either the moveable base, flange base mount or
the hanging model.
2. Materials necessary to construct a concrete base for floor mounted model for
GA301-U & GA301-T only.
3. Gas supply line that is installed to the Gas and Electric Supply according to the:
National Fuel Gas Code, ANSI Z.223.1 (NFPA 54) in the US and Natural Gas
and Propane Installation Code, CSA B149.1 or Propane Storage and Handling
Code, B149.2 in Canada.
4. Electrical supply rated at 24 VAC with two stage control for GA301-U, GA301-H
&GA301-T only.
Even-GLO™ Series GA301 Page 8
October-28-15
WARNING!
Location Planning
General Location Layouts
One Even-GLO heater, at high fire and in windless conditions, has a comfort radius
of about twelve feet (24 ft. circle).
A series of heaters providing area heat should be placed about 14-20 feet apart.
Wind protection has an important influence on the body’s ability to retain radiant heat.
Use natural or newly built wind barriers where possible, such as existing buildings,
shrubbery or tree lines and fences. A clear plastic six-foot fence is used in some
commercial restaurants to give an open look while giving good wind protection.
A patio that has been almost entirely closed in with a roof and windbreak walls or a
tent may be considered an indoor location by some code authorities. The EvenGLO heater has been approved for indoor use in non residential applications
(Natural Gas Models ONLY). Venting of the flue gases is accomplished by means of
an interlocked fan. Refer to the National Fuel Gas Code, ANSI Z.223.1 (NFPA 54) in
the US and CAN/CGA B149.1 and B149.2 Installation Codes in Canada.
Safety Requirements
This heater is NOT approved for any indoor Residential
application. If in doubt of your application consult with your
local fire marshal or gas authority having jurisdiction. Indoor
spaces include but are not limited to attached garages,
solariums, living quarters etc.
1. Never locate the heater directly below electrical lines, gas lines or sprinkler
NOTE: Sprinkler head heat fuse link performance may alter with age.
systems.
2. Do not locate heater too close to vinyl or plastic wall coverings. These materials
may discolour or soften well before they reach combustible limits.
3. The heater requires a minimum clearance from combustible materials. See the
Clearance to Combustible Materials section for specific requirements.
4. Always allow room for removal of the top reflector and heater head for
maintenance purposes.
5. The heater aspirates air for combustion. Do not locate heater where there are
severe draft conditions or airflow restrictions to the heater head base.
Even-GLO™ Series GA301 Page 9
October-28-15
Specifications / Details
Equipment Dimensions
Floor mount models
Model GA301 Model GA301-T
Even-GLO™ Series GA301 Page 10
October-28-15
Specifications / Details
Hanging model GA301- H
1.13"
17.95"
47.98"
Ø39.50"
46.81"
Even-GLO™ Series GA301 Page 11
6 Feet Minimum Clearance Below
October-28-15
Specifications / Details
Portable model GA301- M & GA301- MP
Model GA301- M Model GA301- MP
Even-GLO™ Series GA301 Page 12
October-28-15
Specifications / Details
Clearance to Combustibles
The following clearance data is based on a maximum limit of 90°F plus ambient
temperature.
Note with an ambient temperature of 70°F the surface temperatures at the
clearance distances listed below could reach 160°F Care should be taken with
placement of plastic or vinyl in the proximity of the heater as they tend to distort
and soften at these temperatures.
The INSTALLER is responsible to ensure that building materials with a low heat
tolerance which may degrade at higher temperatures are protected to prevent
degradation.
TOP
CLEARANCE TO COMBUSTIBLES
SIDE
MODEL NO.TOPSIDES BELOW
BELOW
GA 301
MODEL NO.TOPSIDES BELOW
22"
22"33"18"GA 301 H
22"33"18"GA 301 T
22"
22"33"18"GA301-MP
33"18"
33"18"GA301-M
Even-GLO™ Series GA301 Page 13
October-28-15
Specifications / Details
Specifications / Details
Installation / Code Requirements
Installation must comply with local building codes and/or, for the USA/National Fuel Gas
Code, ANZI Z 223.1 (NFPA 54) and for Canada, CAN/CGA B149.1 and B149.2, National
Gas and Propane Installation Code (latest editions).
Appliance must be electrically grounded in accordance with local codes or, in their
absence; the National Electrical Code, ANSI/NFPA 70 in the USA, CSA C22.1 Canadian
Electrical Code in Canada.
NOTE: Some materials deteriorate or soften at sustained temperatures below 160°F.
Consult material manufacturer for recommendations
Even-GLO™ Series GA301 Page 14
October-28-15
Models :
GA301, GA301H & GA301T
Models :
GA301
M & GA301MP
Specifications / Details
Power & Gas Specifications
High fire rate: Natural - 53,000 btuh Propane - 47,000 btuh
Natural Gas: Minimum 6.5 ” W.C. Maximum 14.0 ” W.C.
Propane Gas: Minimum 10.8 ” W.C. Maximum 14.0 ” W.C.
Electric Supply: 24 VAC, 0.8A
High fire rate: Natural - 53,000 btuh
Gas Supply Pressure:
Natural Gas: Minimum 6.5 ” W.C. Maximum 14.0 ” W.C.
Installation or repair should only be done by personnel qualified for the
installation of powered gas appliances.
The appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of ½
psig (3.5 kPa)
The appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psig (3.5 kPa)
Even-GLO™ Series GA301 Page 15
October-28-15
Portable Models (GA301M & GA301MP)
Secure Wheels to Bottom Base
a) Flip Over Base
b) Line-up holes and press Carriage Bolt through Wheel Bracket and Bottom Base.
Place Lock Washer over threads of Carriage Bolt and hand tighten Nut.
c) Tighten Nut with Wrench while making sure Carriage Bolt is properly secured and
not spinning.
Even-GLO™ Series GA301 Page 16
October-28-15
Loading...
+ 36 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.