Table of Contents
1 INTRODUCTION....................................................................................................................................... 1
2 DISPLAY AND KEYPAD FUNCTIONS.................................................................................................. 2
2.1 DISPLAY ...............................................................................................................................................2
2.2 KEYPAD................................................................................................................................................ 3
3 PREPARATION.......................................................................................................................................... 5
3.1 INSERTING THE BATTERIES................................................................................................................... 5
3.2 CONDUCTIVITY ELECTRODE INFORMATION.......................................................................................... 6
3.3 CONNECTING THE ELECTRODE TO THE METER ...................................................................................... 7
3.4 ATTACHING THE ELECTRODE HOLDER TO THE METER ......................................................................... 8
3.4.1 Inserting the electrode into the electrode holder ............................................................................. 8
3.5 CONNECTING THE AC/DC ADAPTER .................................................................................................... 9
3.6 CONNECTING THE RS232C CABLE (ONLY FOR CON 110) ................................................................... 9
3.6.1 RS232C Configuration.................................................................................................................. 10
4 CALIBRATION ........................................................................................................................................ 11
4.1 IMPORTANT INFORMATION ON METER CALIBRATION......................................................................... 11
4.2 PREPARING THE METER FOR CALIBRATION ........................................................................................ 12
4.3 TEMPERATURE CALIBRATION............................................................................................................. 13
4.4 SELECTION OF AUTOMATIC OR MANUAL CALIBRATION..................................................................... 14
4.5 AUTOMATIC CALIBRATION (FOR CONDUCTIVITY CALIBRATION ONLY) ............................................ 15
4.6 MANUAL CALIBRATION (FOR CONDUCTIVITY & TDS CALIBRATION) ............................................... 17
4.7 TDS CALIBRATION............................................................................................................................. 18
4.7.1 Calibrating for TDS Using Conductivity Standards & adjusting TDS factor............................... 18
4.7.2 Setting the TDS Conversion Factor...............................................................................................18
4.7.3 Calibrating for TDS using TDS standards.................................................................................... 19
5 MEASUREMENT..................................................................................................................................... 20
5.1 AUTOMATIC TEMPERATURE COMPENSATION ..................................................................................... 20
5.2 MANUAL TEMPERATURE COMPENSATION.......................................................................................... 21
5.2.1 Setting the manual temperature compensation value.................................................................... 22
5.3 TAKING MEASUREMENTS ................................................................................................................... 23
5.3.1 Taking measurements with READY indicator selected on............................................................ 23
5.3.2 Taking measurements with the Auto HOLD feature selected on................................................... 23
5.4 USING MANUAL RANGING FUNCTION ................................................................................................ 24
5.4.1 Selecting manual range................................................................................................................. 24
5.5 HOLD FUNCTION............................................................................................................................... 25
6 MEMORY FUNCTION............................................................................................................................ 26
6.1 MEMORY INPUT.................................................................................................................................. 26
6.2 MEMORY RECALL............................................................................................................................... 27
7 PRINT FUNCTION (FOR CON 110 ONLY)......................................................................................... 28
7.1 USING CON 110 METER WITH PRINTER OR COMPUTER...................................................................... 28
7.2 SENDING DATA TO COMPUTER OR PRINTER....................................................................................... 29
7.2.1 Printing Current Data Manually................................................................................................... 30
7.2.2 Print Data on Timed Interval........................................................................................................ 30
7.2.3 Print Data from Stored Memory ...................................................................................................32
8 ADVANCED SETUP FUNCTION.......................................................................................................... 34
8.1 ADVANCED SETUP MODE OVERVIEW............................................................................................... 36
8.2 P1.0: UNIT CONFIGURATION (COF).................................................................................................... 38
8.2.1 P1.1: Selection of READY and Auto HOLD function.................................................................... 38
8.2.2 P1.2: Selection of °C or °F ........................................................................................................... 39
8.2.3 P1.3: Selection of Automatic or Manual Temperature Compensation.......................................... 40
8.2.4 P1.4: Selection of TDS Conversion Factor................................................................................... 41