AP4382-2000
Action PAK
®
AP4382
DC Input, Bipolar Output,
Field Configurable Isolator
Provides a Fully Isolated DC Output
in Proportion to DC Input
Eliminates Ground Loops
Field Configurable Input Ranges: 10mV to 100V,
1mA to 100mA
Two Field Configurable Output Ranges: -5 to 5V
and -10 to 10V
Description
The field configurable AP4382 isolator offers wide ranging input
and output capability for scaling and transmitting analog DC
signals. The AP4382 will accept input voltage spans from 10mV up
to 100 volts, as well as input current spans from 1mA to 100mA.
The input zero and span potentiometers enable 50% input zero
and span adjustability. For example, the 0-10V input range can be
elevated to 5-10V, or compressed to 0-5V. The AP4382 offers two
(2) bipolar output ranges: -5 to 5V and -10 to 10V.
Model AP4382 also accepts bipolar inputs and offers selectable
normal or reverse acting operation
The AP4382 is an industrial isolator - the output is optically isolated
from its input up to 1500 VDC. The ASIC-based I/O channel is
independently transformer isloated from the selectable 120/
240VAC power supply.
Application
The Action Pak AP4382 field configurable isolator is useful in
eliminating ground loops, converting signal levels and providing
signal drive. The wide ranging capability of the AP4382 provides
quick universal spare part coverage.
Diagnostic LED
The AP4382 is equipped with a dual function LED signal monitor.
The green, top-mounted LED indicates line power and input signal
status. Active line power is indicated by an illuminated LED. If the
input signal is 10% above the full scale range, the LED will flash at
8Hz. Below 0%, the flash rate is 4Hz.
Plug-in Installation
Selectable 120/240VAC Input Power
(9 to 30 VDC Available)
ASIC Technology for Enhanced Reliability
Warning: Do not change switch settings with power applied.
Severe damage will result!
Input
1. Position input jumper “W1” for Current (I) or Voltage (V) input.
V
I
W1
Current Voltage
W1
2. Set position 5 of the Input Range Selector for Unipolar (e.g. 0
to 5V) or Bipolar (e.g. -5 to 5V) operation.
ON
>
123
4
5
6
Unipolar Bipolar
Note: A bipolar range selection will double any input range from
Table 1 (e.g, 10V span = -10 to 10V bipolar span)
3. Set position 6 of the Input Range Selector for Normal or Reverse
operation. Reverse acting produces a decreasing output with an
increasing input.
ON
>
123
4
5
6
Normal Reverse
I
ON
>
123
ON
>
123
V
4
5
6
4
5
6
Options
U Urethane
coating of internal circuitry for protection from
corrosive atmospheres.
Configuration
The factory preset input is 4-20mA and the output is -10 to 10V,
as shown in Figure 1. The supply power is configured for 120 VAC
operation. For other I/O ranges, remove the four base screws and
case to access the I/O card.
Refer to Figure 1 for configuration and program the I/O channel
as desired. Replace the cover before applying power.
4. Using Table 1, configure positions 1 through 4 of the Input Range
Selector for the desired maximum input. Round the desired maximum input value to the next highest range (e.g., 0-70V = 100V range).

Warning: Do not configure the output ranges with the power on.
Damage to unit will result.
Output
1. Position output jumper "W2" for -5 to 5V or -10 to 10 V
W2
-10 to 10V -5 to 5V
W2
Power
1. Configure the AC jumpers for either 120 or 240 VAC operation.
See Figure 2.
Calibration
1. Connect the input to a calibrated DC voltage or current source
and apply power. Wait 1 hour for thermal stability before
monitoring the voltage/current output. Refer to PIN CONNECTIONS.
2. Set the calibrator to the desired minimum input and adjust the
Zero, 20-turn, potentiometer for desired minimum output.
3. Set the calibrator to the desired maximum input and adjust the
Span, 20-turn, potentiometer for desired maximum output.
4. Repeat steps 2 and 3 for best accuracy.
Table 1: AP4382 Input Ranges
Voltage* Current*
20mV 2mA
50mV 5mA
100mV 10mA
200mV 20mA
500mV 50mA
1V 100mA
2V
5V
10V
25V
50V
100V
Input Range
Selector (SW1)
ON
>
4
12 3
ON
>
1
ON
>
1
ON
>
1
ON
>
1
ON
>
12 3
ON
>
1
ON
>
12 3
ON
>
12 3
ON
>
1
ON
>
12 3
ON
>
12 3
4
23
234
234
4
23
4
4
23
4
4
234
4
4
5
6
5
6
5
6
5
6
5
6
5
6
5
6
5
6
5
6
5
6
5
6
5
6
*Note: Use jumper (W1) to configure either voltage or current input.
For high voltage inputs >100V consult factory.

I/O Card Configuration Top View Diagram
W1
I/V Input Selection
V
Diagnostic
LED
I
Input Range
Selector (SW1)
Output Range
Selector (W2)
Span
Zero
Top
ON
>
12 3
5
4
-10 to 10 V
-5 to 5V
6
Figure 1: AP4382 I/O card factory calibration:
4-20mA input, -10 to 10V output
Warning: Do not configure I/O switch
ranges with power on. Damage will result!
Warning: Applying voltage to the
input with W1 in current (I) position
will result in damage to the unit.
Warning: Do not change
with power connected!
Figure 2: 120/240 VAC Selection
Mounting
All Action Paks feature plug-in installation. Model AP4382 uses an 8-pin
base and either molded socket M008 or DIN socket MD08.
Dimensions
Dimensions are in millimeters (inches)
M008 (Track/Surface)
MD08 (DIN Rail)Mark II

Specifications
Input:
Voltage Input (field configurable):
Full Scale Range: 10mV to 100V
Impedance: >100K Ohms
Overvoltage:
400 Vrms, max (Intermittent)
264 Vrms, max (Continous)
Current Input (field configurable):
Full Scale Range: 1mA to 100mA
Impedance: 20 Ohms, typical
Overcurrent: 170mA rms, max
Overvoltage: 60VDC
Common Mode (Input to Ground):
1500VDC, max
Zero and Span Range:
Zero Turn-Up:
0 to 50% of full scale range
Span Turn-Down:
100 to 50% of full scale range
Output:
Voltage Output
Output: -10 to 10V, -5 to 5V
Impedance: <10 Ohms
Drive: 10mA, max (1K Ohms min. @ 10V)
LED Indication (green):
Input Range >110% input: 8Hz flash
<0% input: 4Hz flash
Accuracy (Including Linearity, Hysteresis):
<20mV/2mA: ±0.35% of full scale, typical,
0.5%, max
>20mV/2mA: ±0.1% of full scale, typical,
0.2%, max
Response Time (10-90%):
200 mSec., typical
Stability (Temperature):
±0.025% of full scale/°C, typical,
±0.05%/°C, max
Common Mode Rejection:
DC to 60Hz: 120dB
Isolation (Input to Output):
1500 VDC between input, output and power
ESD Susceptibility:
Meets IEC 801-2, Level 2 (4KV)
Humidity (Non-Condensing):
Operating: 15 to 95% (@ 45°C)
Soak: 90% for 24 hours (@ 65°C)
Temperature Range:
Operating: -15 to 60°C (5 to 140°F)
Storage: -25 to 70°C (-13 to 158°F)
Power:
Consumption:
3W typical, 5W max
Standard:
selectable 120/240VAC, ±10%, 50-60Hz
Optional:
9 to 30VDC, inverter isolated
Weight:
0.60lbs
Agency Approvals:
CSA certified per standard C22.2, No. M1982
(File No.LR42272-54).
UL recognized per standard UL508
(File No. E150323).
Ordering Information
Specify:
1. Model: AP4382-2000
2. Option: U, see text
3. Line Power: 120/240 VAC or 9 to 30 VDC
4. Factory calibration (C620): Specify input range, output range and power.
(All power supplies are transformer-isolated from the internal circuitry.)
Accessories:
M801-0000 Retaining Spring
M008-A 8 pin Track Mount Socket
M004-0000 4 ft Long Channel Track
MD08-0000 8 pin DIN Mount Socke
Printed on recycled pape
Action Instruments
Pin Connections
1 Power (Hot)
2 Shield (Gnd)
3 Power (Neu)
4 Spare Termination
5 Input (+)
6 Input (-)
7 Output (+)
8 Output (-)
DC Power: PIN 1 = (+); PIN 3 = (-)
Chessell
Eurotherm