Eurotherm AP4300 Data Sheet

Page 1
Action Pak
®
DC-Input Isolating Signal Conditioner
Model AP4300
Provides a Fully Isolated DC output in Proportion to a DC Input
• Protects Equipment with 600V Input to Output Isolation
• Voltage or Current Input
• Eliminates Ground Loops
• Easy Plug-in Installation/Low Mean-Time-to-
Repair
• AC Line Powered (DC Optional)
• UL Recognized
• CSA Certified
• Three-Year Warranty
APPLICATION
Model AP4300 is useful in eliminat­ing ground loop problems in existing systems, and is a preven­tive measure in the design of new systems. The DC input/output isolation allows a difference in potential of up to 600V between the input and output ground. This allows the benefits of grounded inputs to be realized, without creating ground loops.
For wide ranging DC isolating signal conditioners offering field configurable input, ouput, ranges and functions refer to Action Instruments' Models AP4380 and AP4390.
OPERATION
The DC input is amplified and filtered before being fed to a comparator. The comparator, in conjunction with a precision-ramp generator, outputs a duty-cycle which in turn drives an optical isolator. The photo-isolator accu­rately reproduces the duty-cycle and provides an isolated signal.
The isolated duty-cycle is then converted back to a DC level proportional to the input. The DC signal is then buffered by an output stage which allows zero and span adjustments. In units having a current output (e.g. 4-20mA) the output is a constant current source, controlled by the output buffer stage. With voltage output units (e.g. 0-10V) the output is taken directly form the discrete driver transistor of the buffer stage. The internal power supplies for the input and output circuitry use indepen­dent transformer secondaries to maintain isolation.
OPTIONS
CS Canadian Standards
Association Certification (standard power only, consult factory).
U Urethane coating of internal circuitry for protection from
corrosive atmospheres
UL UL Recognition.
CALIBRATION
Top-accessed screwdriver adjust­ments provide typical ±10% zero and span adjustability. Calibration is referred to input in that adjust­ments are to correct for input/ sensor variations. Zero is adjusted for the specified minimum output with the input at the desired mini­mum. Span is adjusted for the specified maximum output with the input at the desired maximum. Repeat adjustments for maximum accuracy.
Page 2
Input/Output Ranges
Table 1:AP4300 Standard Inputs
0-10V 4-20mA
Table 2: AP4300 Standard Outputs
0-10V 4-20mA
Table 3: AP4300 Input/Output Limits
Input
Min. Span Min. Span Max. Input Max. Input Voltage (Current) (Voltage) (Current)
50mV 1mA 250V 1A
Output
Min. Span Min. Span Max. Output Max. Output
Voltage (Current) (Voltage) (Current)
100mV 1mA 10V 50mA
SPECIFICATIONS
Input Impedance
Voltage Input
> 200K
Current Input
10, 200mV shunt (F.S.)
Output Impedance
Voltage Output
< 10
Current Output
> 100k
Accuracy (Including Linearity, Hysteresis, and Repeatability)
±0.1% of span typical
Response Time
100 mSec. typical
Linearity (best straight line and linear input)
±0.05% of span typical
Stability
±0.025%/°C typical
MOUNTING
All Action Paks feature plug-in installation using either molded socket (M008) or DIN rail (MD08).
ORDERING INFORMATION
Specify:
1. Model: AP4300
2. Input Range (see tables 1,3)
3. Output Range (see tables 2,3)
4. Options: CS, U, UL (see text)
5. Line Power (see specs) (All power supplies are trans­former-isolated from the internal circuitry.)
Output Ripple
0.2% of max. span, rms or 2mV whichever is greater
24VDC power, 0.5% of max.
span, rms or 5mV whichever is greater
Output Drive
Voltage Output
10mA, max, 1K
minimum load
Current Output
15V compliance @ 20mA,
750 maximum load
Common Mode Rejection
60 Hz: >120dB DC: >100dB
Isolation (Input to Output)
600V DC or peak AC
Temperature Range
Operating: 0 to 60°C (32 to 140°F) Storage: -20 to 85°C (-4 to 185°F)
33.3
(1.31)
56
73.7
(2.90)
7
812
9.53
(.375)TYP
23.0 (.91)
M008 (Track/Surface)
39.6
(1.56)
43
#6-32 TERMINAL SCREW
3.74 (.15)DIA.
MOUNTING HOLE
CHANNEL TRACK
(4 INCH LENGTH)
Power
Consumption: 3W typical, 5W
max.
Standard: 120VAC (±10%, 50-
400Hz)
Available: 100, 220, 240VAC,
(±10%, 50-400Hz)
Optional: 24VDC (±8V, inverter-
isolated)
PIN CONNECTIONS
AP4300
1 AC Power (Hot) 2 Shield (Gnd) 3 AC Power (Neu) 4 No Connection 5 Input (+) 6 Input (-) 7 Output (+) 8 Output (-) DC Power: pin 1= (+); pin3 = (-)
DIMENSIONS
Dimensions are in Millimeters (Inches)
Retaining Spring Available: Model M801
MD08 (DIN)
All prices and specifications subject to change without notice