Euroterm ESK 2.5 SB, ESK 2.5 SB T, ESK 2.5 SB - TU Installation Manual

The highest eciency
The eciency of the selective collectors is the highest, commercially accessible for residential
types of applications.
Release up to 50% more power by square meter than conventional solar
collector.
Attractive design
Unique product, with optimize and attractive
design.
Reliable and tested materials
Tempered glass, selective foil, embossed back side metal sheet and strong aluminum prole, enabling reliable functioning.
SOLAR COLLECTORS
Excellent eciency, the best characteristics, high quality
Installation manual
CONTENTS
Remarks ............................................................................................................................................. 5
Technical specications ........................................................................................................... 6-9
Safety instructions ...................................................................................................................... 10
Installation instructions ...................................................................................................... 11-12
Filling and testing ..................................................................................................................... 13
Fixing and mounting .......................................................................................................... 14-15
Connections ............................................................................................................................ 16-19
Collector array layout .............................................................................................................. 20
Pipe connections ........................................................................................................................ 21
Installation schemes .................................................................................................................. 22
REMARKS
A solar collector generates heat from sunlight and all other types of light. This leads to collector con­nectors getting very hot, even when they are not lled. This creates a risk of burning. Cover the collec­tors with opaque material until the installation has been completed. It is recommended you leave the col­lector inside its packaging until it is installed.
Never install any shut-o valves in the line between the collectors and the safety valve. The safety valve re­sponds at 87 PSI pressure.
Never set the Solar loop presure greater then potable pressure.
Neither drop the collector nor any­thing onto the collector.
Never step onto or stand on the col­lector.
Never leave the collector unsup­ported or unsecured. The glass could break if the collector falls over.
All sensor wiring needs to be rated for expected temperatures. All sen­sor wiring needs to be protected from degradation and false signals.
!
!
!
!
!
!
!
copper absorber with Eta plus selective foil
0.2 mm, corrugated
low iron tempered glass, 4 mm thick
dimensions 2149 x 1159 x 90 mm
Technical characteristics:
SELECTIVE SOLAR COLLECTOR
TYPE ESK 2.5 - SB
copper absorber with Eta plus selective foil
0.2 mm, corrugated
low iron tempered glass, 4 mm thick
dimensions 2149 x 1159 x 90 mm
Technical characteristics:
SELECTIVE SOLAR COLLECTOR
TYPE ESK 2.5 - SB U
ESK 2.5 SB - U
ESK 2.5 SB
Tip
Gross area
Light entering area
Absorber surface (corrugate)
Absorber material
Absorption coefficient (Eta plus)
Emission coefficient (Eta plus)
Cu Pipe register frame
Collective Cu pipe frame
Absorber volume
Transparent front cover
Solar light transmission through glass
Solar energy transmission through glass
Number of connections
Connection diameter
Max. working / test pressure
Stagnation temperature
Insulation - back side
Insulation - on the sides
Back area
Collector construction
Welding method
Height
Width
Depth
Weight
(m
2
)
(m
2
)
(m
2
)
(%)
(%)
(mm)
(mm)
(l)
(%)
(%)
(R)
(bar)
(
o
C)
(mm)
(mm)
(mm)
(kg)
copper sheet with "Eta plus" selectiv surface coating
4mm tempered solar glass - AGC
10 / 14
199
40 mm glass wool (50kg/m
3
)
-
0.5 mm embossed aluminium sheet
aluminium profil AlMgSi 0,5 F22
ultrasonic
2,49
2,35
2,32
95 ± 2
5 ± 2
Ф 8 x 0,5
Ф 22 x 0,8
1,7
92 ± 2
91 ± 2
4
Ф 22
2149
1159
90
44
2,49
2,35
2,32
95 ± 2
5 ± 2
Ф 8 x 0,5
Ф 22 x 0,8
1,7
92 ± 2
91 ± 2
2
Ф 22
2149
1159
90
44
Collector eciency
Pressure drop
Collector efficiency for G = 800 W/m
2
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10
Tm* [Km2/W]
Absorber
Aperture
Gross
Reference area Absorber area Aperture area Gross area
η0 (-)
807.0 457.0 667.0
a
1
81.4 54.4 25.4 )K²m/W(
a2 (W/m²K²) 0.0042 0.0041 0.0039
Pressure drop in Pa
0
200
400
600
800
1000
1200
1400
0 50 100 150 200 250 300 350 400
Flowrate [l/h]
20° C
Flow rate [l/h]
0 80 160 240 320 400
Pressure drop [Pa]
0 155 352 593 877 1203
copper absorber with Eta plus selective foil
0.2 mm, corrugated
low iron tempered glass, 9mm lled with ar­gon, 2 x 4 mm thick
dimensions 2149 x 1159 x 102 mm
Technical characteristics:
Technical characteristics:
copper absorber with Eta plus selective foil
0.2 mm, corrugated
low iron tempered glass, 9mm lled with ar­gon, 2 x 4 mm thick
dimensions 2149 x 1159 x 102 mm
SELECTIVE SOLAR COLLECTOR
TYPE ESK 2.5 - SB T
SELECTIVE SOLAR COLLECTOR
TYPE ESK 2.5 - SB TU
Loading...
+ 16 hidden pages