European Touch FORTE’, ALTERA Owner's Manual

The World's Finest Pedicure Spas
Solace Spas
FORTE
Crystal Clean Pipe-Free
Traditional Whirlpool
Document ID:06080001 Rev: E Tec hnical Support: 800-626-6912 Pa ge 1 of 24
and ALTERA
&
European Touch - Limited Warranty
EUROPEAN TOUCH manufactu res the Solace® Whirlpool Pedicure Spa with the highest standards for quality materials and workmanship accordingly; EUROPEAN TOUCH expressl y warran ts thei r products as
follows:
To the original ow ner of the Solace® Whirlpool Pedicure Spa (herein called "pedicure spa"): EUROPEAN TOUCH may repair or replace at its op tion, any pedicure spa found to be defe cti ve in material or
workmanship upon inspection by an authorized representative of EUROPEAN TOUCH. This warran ty covers the following components for the following time periods:
Recirculating Pump: Two (2) years from date of shipment.
All other components: One (1) year from date of shipment.
The exchange of a pedicure spa is limited to supplying a replacement pedicure spa of comparable style a nd size. EUROPEAN TOUCH may, at its own discre tion, use refurbished parts or pedicure
spas for replacement purposes. Owner must pay all labor and shipping charges necessary to replace or repair the pedicure spa. NO CONSEQUENT IAL, INCIDENTAL, OR CONT INGENT
DAMAGES WILL BE ALLOWED WHATSOEVER. This warranty is null and void if the pedicure spa is removed from its place of initial installation, or is not installed in accordance with federal, state or local
codes and ordinances. Furthermore, this warranty does not apply if the pedicure spa has been subject to misapplication, improper installation or maintenance, negligence, improper cleaning or other circumstances
be yond EUROPEAN TOUCH's contro l .
NOT COVERED
1) Damage to pump parts and/or motor parts due to obstruction in plumbing lines, etc.
2) Staining, fading or discoloration of plastic surfaces due to exposure and/or the use of harmful cl ea ni ng ag ents or ch emi cal s.
3) Staining, fading or discoloration caused by improper or poor water additives not related to maintenance of proper water are not covered by this warranty.
4) Malfunctions or damage caused by improper installation; including not meeting local and state plumbing, electrical, and building codes.
5) Staining, fading or discoloration of the vinyl seat, armrests or footrest.
6) Damage resulting from standing in the basin.
7) Freight damage, misuse, neglect, accident, natural disaster, and abuse.
8) Unauthorized repairs.
Should service be required for any reason of any defect or any malfunction during the warranty period, please contact:
EUROPEAN TOUCH
Technical Support
8301 W. Parkland Court
Milwaukee, WI 53223
Phone Number: 414-357-7016
Toll Free: 1-800-626-6912
Fax: 414-357-6360
http://www.europ eantouch.com
The owner agrees by u sing this pedicure spa that the obligation of EUROP EAN TOUCH shal l not extend to indirect or contingent damage, of injury, which may result from such use that the obligation of EUROPEAN
TOUCH are limited to those set forth he rei n, and other obligations, expressed or im pli ed are assum e d by EUROPEAN TOUCH.
No d ealer or other person has any authority to bind EUROPEAN TOUCH to changes or additions to thi s warranty or its products. Accordi n gl y, EUROPEAN TOUCH i s not responsible for any such warranties or
representations.
Document ID:06080001 Rev: E Tec hnical Support: 800-626-6912 Pa ge 2 of 24
Certificate of Compliance
For
European Touch
8301 W. Parkland Court
M ilwaukee, WI
U.S.A. 53223
For Comp liance of:
Equipment : W hirlpool Pedicure Spa Model No.: SOLACE – PF & SOLACE – PF PDP Rated: 220-240VAC, 50Hz, 7.5A
To the following standard(s):
EN60335-1:2002 EN60335-2-32:2002 EN 55014-1 (Generic): 2001
EN 55014-2 (Generic): 2003 EN61000-4-2 (Criteria C): 2001 EN61000-4-3:2002 EN61000-4-4: 1995 EN61000-4-5: 2001
EN610004-6: 2001 EN61000-4-11: 2004
Project No.: 8311-1 Issued by: Issue Date: December 30, 2005
President Expiry Date: December 30, 2008
ONE STOP GLOBAL CERTIFICATION SOLUTIONS
Refer to proj ec t file for co mpl ete i nf orma tion on Certi fi c at e
Document ID:06080001 Rev: E Tec hnical Support: 800-626-6912 Pa ge 3 of 24
OWNERS MANUAL For
Solace® Whirlpool Pedicure Spa Models:
FORTEand ALTERA
Important Information
Serial Number:
W/O Num ber:
Installed by:
Ins tallation Date:
Serial Number
W/O Num ber
: Vietnamese and Korean translations available upon request.
Note
Document ID:06080001 Rev: E Tec hnical Support: 800-626-6912 Pa ge 4 of 24
Table of Contents
European Touch - Limited Warranty ..................................................................................................... 2
Certificate Of Compliance....................................................................................................................... 3
Important Inform ation............................................................................................................................... 4
Introduction................................................................................................................................................ 6
Important Requirem ents.......................................................................................................................... 6
Precautions............................................................................................................................................ 6
Health Risk Warning ............................................................................................................................ 6
Ins tallation Specifications Summary......................................................................................................7
Location And Support.......................................................................................................................... 7
Important Installation And Utility Information....................................................................................... 8
Dimensional Drawings............................................................................................................................. 9
Crystal Clean™ Pipe-Free® And Traditional Whirlpool (With Jets) ............................................. 9
Crystal Clean
Pipe-Free®...............................................................................................................10
Traditional Whirlpool (With Jets) ......................................................................................................11
Specifications ..........................................................................................................................................12
Unpacking The Cushions...................................................................................................................... 14
Remote Control Configurations............................................................................................................14
Attaching The Cushions ........................................................................................................................ 15
Component Reference..........................................................................................................................16
Pedicure Product Guidelines................................................................................................................ 16
Crystal Clean
Pipe-Free® Spa - Operating Ins tructions ................................................................17
Crystal Clean™ Pipe-Free® Spa - Cleaning And Disinfecting Procedures ....................................18
Traditional Whirlpool (With Jets) - Operating Ins tructions ...............................................................19
Traditional Whirlpool (With Jets) - Spa Cleaning And Disinfecting Procedures...........................20
Removal / Replacing Jet Parts.........................................................................................................21
Removal / Replacing Suction Cover................................................................................................21
Removing / Replacing Drain Handle...............................................................................................22
Removing / Replacing Im peller ........................................................................................................22
History And Notes ..................................................................................................................................23
Document ID:06080001 Rev: E Tec hnical Support: 800-626-6912 Pa ge 5 of 24
Introduction
Thank you f or selecting EUROPEA N TOUCH, the leading designer, manufacturer, and marketer of pedicure spas in North A merica. The Solace
to as
pedicure spa) are i nnovative w hirlpool pedicure spas that have been designed to serve you
dependably f or many years. Please take time to thoroughly read this entire manual before installation and use. If you have any problems or have questions regarding your pedicure spa, please contact
EUROPEA N TOUCH’s Techn ical Support Department at 1-800-626-6912, Monday through Friday 8 AM to 5 PM CST. Af ter hours calls are recorded and attended to the next business day.
®
Forte’ and Solace® Altera ped icure spas (herein ref erred
Important Requirements
EUROPEA N TOUCH requires that you contact a local, licensed plumber and licensed electrician to install your new pedicure spa. Installation must be in compliance w ith all your local and state building
codes. Y our pedicure spa cannot operate ef ficiently or saf ely unless it is provided w ith adequate electrical pow er, sufficient w ater pressure, proper water temperature, and required dra inage
capabilities. Contact your local building inspector f or information and local code compliance procedures that need to be f ollow ed w hen having your pedicure spa instal led. Subsequent inspections
and approvals that may be required are the responsibility of the purchaser. (See lim ited warranty
regarding incidental or consequential exclusions – page 2).
Precautions
Do not stand in the basin of the pedicure spa!
Excessive water temperature is dangerous and should be checked before use.
Maximum operating water temperature should not exceed 105 maximum supply water temperature should not exceed 150° F (66° C).
Always enter and exit the pedicure spa slowly and carefully.
Close side arms rests before operating the chair seat movement.
Never bring or operate any electrical devices into or near the pedicure spa.
This pedicure spa has a weight capacity of 250 pounds (113.4kg).
°
F (41° C) and the
Health Risk Warning
Individuals whose feet or legs are inflamed or have open wounds should not be allowed to use the pedicure spa at any time. Nail technicians should advise clients to consult their physician
before using the pedicure spa if there is any sign of fungal infection, swelling, fracture, or persistent pain. In some cases diabetics may experience improved circulation in their feet, but should first consult their physician prior to receiving a pedicure. If the client experiences any
pain or discomfort, immediately discont inue t he use of t he pedicure spa.
Your client’s massage and pedicure spa experience should be pleasant and comfortable.
Document ID:06080001 Rev: E Tec hnical Support: 800-626-6912 Pa ge 6 of 24
Installation Specifications Summary
)
)
)
Note: Failure to comply with federal, state or local codes and ordinances will result in the warranty being null and void.
As stated, the pedicure spa installation must comply w ith all plumbing and electrical codes. A licensed plumber and licensed electrician must co mplete the app licab le connections of the pedicure spa.
Location and Support
Select a level location. The f loor structure beneath the ped icure spa must be capable of supporting the occupied pedicure spa.
For the seat back to f ully recline, the pedicure spa base must be mounted a minimum distance f rom the w all:
Forte’ model w ith full recline option 25” (64 cm Forte’ model 18” (46 cm
Altera model 12” (31 cm
= “X” dimension, below , by model.
Document ID:06080001 Rev: E Tec hnical Support: 800-626-6912 Pa ge 7 of 24
Important Installation and Utility Information
Electrical Service:
110V: A 110V, 60 Hz, 15 Amp GFCI protected grounded circuit must be used to supply power
to the pedicure spa. (220V if ordered in 220V conf iguration)
220V: A 220-240V AC, 50Hz, 7.5 Amp GFCI protected grounded circuit must be used to supp ly
Water Supply:
All plumbing connections must conform to local codes. Nor mal w ater pressure of 30 to 80 PSI is required to correctly fill the basin to the proper level.
The hot w ater supply temperature must not exceed 150 accordingly.
For hot and cold w ater supply fittings and pow er drain fittings location, see f igure 1 below . Caref ully connect the incoming w ater supply lines to the appropriate fittings located on the back of the pedicure spa. Shut-of f valves are recommended.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply w ith ANSI/ASME A112.18.3M , A112.18.1M, and CSA B125
ANSI/ASME A112.18.3 M (Performance Require ments for Backflow Protection Devices and Systems in Plumbing Fixture Fittings) is appl icable to plumbing fixture f ittings w ith outlets not protected by an air
gap. Included in the possible range of applications are fittings w ith hose connected outlets, f ittings w ith pullout spout, hand h eld show ers, shampoo fittings and deck-mounted f ittings. ASME A112.18.3 M is now referenced in ASME A112.18.1M ( Plu mbing Fixture Fittings) and CSA B125. Check valves are
listed to both standards w ith the Canadian Standards Association, IAPMO and UL.
ANSI - A merican National Standards Instit ute ASME - American Society of Mechanical Engineers
CSA - Canadian Standards A ssociation IAPMO - Internat ional Association of Plumbing and Mechanical Off icials
UL - Underw riters Laboratory
The pedicure spa drain must meet local plumbing codes. Check valve for drain (not provided) must be installed by a licensed plumber.
Pedicure spa must be securely fastened to the f loor as shown in figure 2 below . Fasten the pedicure spa to the f loor w ith at least tw o fasteners, one in the middle plastic support and on e in the rear plastic
support.
Back of Pedicure Spa Install Fasteners Here
Figure 1 Figure 2
pow er to the pedicure spa per local code.
°
F (65° C). Adjust your hot w ater heater
Document ID:06080001 Rev: E Tec hnical Support: 800-626-6912 Pa ge 8 of 24
Loading...
+ 16 hidden pages