European Home Installation, Operation And Owner's Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
Installation,
Operation,
and
Owner’s Manual
J SERIES
Outdoor · Gas · Fireplace
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
-- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
JVF-60-M2-S
JVF-60-M2-ST
Gas Fireplaces
WARNING: Improper installation, adjustment,
alteration, service or maintenance can
cause injury or property damage. Read the
installation, operating, and maintenance
instructions thoroughly before installing or
servicing this equipment.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING: FOR OUTDOOR USE ONLY
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the re department.
--An LP cylinder not connected for use shall not be
stored in the vicinity of this or any other appliance.
Solid fuels shall not be burned in this appliance.
Report # 0284GF009S
JVF-M2 Series Outdoor Gas Fireplace
1
This manual is available in Canadian French
upon request.
January 2019
IGM2S190417
TABLE OF CONTENTS
Important Safety Information 3
Important Safety Information About Propane 4
Specications and Dimensions 5
Clearances 9
Installation 10
Electric Installation 11
Gas Installation 13
Enclosing the Fireplace 15
Framing 16
Trim and Finish 17
Operating the Fireplace 20
Maintenance 22
Installation Record 24
Warranty 25
Appendix A: LP Installation 26
JVF-M2 Series Outdoor Gas Fireplace
2
IGM2S190417
IMPORTANT SAFETY INFORMATION
Read these instructions carefully before installing or trying to operate this gas appliance.
Thank you for purchasing a J-M2 Series Outdoor Gas Fireplace by European Home. This replace has been
designed to provide you with safe, trouble-free operation.
Please read this manual thoroughly before beginning the installation of your replace. It has information which
is important for safe installation and operation.
Please inspect your shipment for completeness and any damage. Contact your retailer if any damage is found.
Do not install your appliance with any damaged or substituted parts.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to
avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of the appliance.
Clothing or other ammable materials should not be hung from the appliance or placed on or near the
appliance.
Any guard or other protective device removed for servicing the appliance shall be replaced prior to operating
the appliance. Installation and repair should be done by a qualied service person.
The appliance should be inspected before use and at least annually by a qualied service person. More
frequent cleaning may be required as necessary.
It is imperative that the control compartment, burners, and circulating air passageways of the appliance are
kept clean.
SOLID FUELS SHALL NOT BE BURNED IN THIS APPLIANCE
Keep the appliance area clear and free from combustible materials, gasoline, and other ammable vapors and
liquids.
Do not use this appliance if any part has been under water. Immediately call a qualied service technician to
inspect the appliance and to replace any part of the control system and any gas control that has been under
water.
JVF-M2 Series Outdoor Gas Fireplace
3
IGM2S190417
IMPORTANT SAFETY INFORMATION ABOUT PROPANE (LP) GAS
This gas replace is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired,
the optional factory-supplied conversion kit must be used.
When using propane (LP), the gas supply cylinder to be used must be:
1) constructed and marked in accordance with the U.S. Department of Transportation (D.O.T.) Specications for LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSA-B339, as applicable,
2) provided with a listed overlling prevention device, and
3) provided with a cylinder connection device compatible with the connection for the appliance.
4) If LP is hard plumbed to the replace, the propane storage tank must have a pressure regulator set for 11” w.c. (2.74 kPa).
Note
If a propane hose is used to connect a propane cylinder to the replace, the following is required:
Inspect the hose before each use of the replace.
The hose assembly must be replaced prior to the replace being put into operation if there is evidence
of excessive abrasion or wear or if the hose is damaged. The replacement hose assembly must be a
regulator hose with a QCC-1 connection and an outlet pressure set for 11” w.c. (2.74 kPa).
Locate the hose out of pathways where people may trip over it or in areas where the hose may be
subject to accidental damage.
JVF-M2 Series Outdoor Gas Fireplace
4
IGM2S190417
SPECIFICATIONS AND DIMENSIONS
SPECIFICATIONS
Model
Gas
Input MaximumBtu/hr65,67864,211
Input MinimumBtu/hr49,90148,308
Maximum Supply
Pressure
Manifold Pressure
Maximum
Manifold Pressure
Minimum
Electrical RatingV AC120
in. w.c.7.011.0
kPa1.742.74
in. w.c.5.510.25
kPa1.372.55
in. w.c.3.56.0
kPa0.871.5
JVF-60-M2-S
JVF-60-M2-ST
Natural
GasLP(Propane)
Frosted Glass
Clear Glass x2
x1 Single Side
x2 See-Through
Stainless Steel
Wall Panels x2
Glass Capture
Panel x2
8-32 Pan Head
Screw x2
Left
Bracket
JVF-M2 Series Outdoor Gas Fireplace
Wind Guard (Single Sided Only)
FIGURE 1
5
Right
Bracket
IGM2S190417
SPECIFICATIONS AND DIMENSIONS
A
D
E
FIGURE 2: JVF-M2-60-S
F
C
B
G
D
A
F
G
B
C
E
JVF-60-M2-S
JVF-60-M2-ST
(overall width*)69⁄”1769 mm
A
B (viewable width)60”1524 mm
C (burner length)49¼”1251 mm
D (viewable height)17½”444 mm
E (base to opening)7½”190 mm
F (overall depth)18”457 mm
G (overall height)28”711 mm
*overall width does NOT include the nailing anges
FIGURE 3: JVF-M2-60-ST
UNIT WEIGHT
Pounds Kilograms
18081.6
JVF-M2 Series Outdoor Gas Fireplace
6
IGM2S190417
SPECIFICATIONS AND DIMENSIONS
CERTIFICATION
OMNI-Test Laboratories, Inc. has certied that the J Series Outdoor Gas Fireplace meets the following standards:
• ANSI Z21.97-2014 “Standard for Outdoor Decorative Gas Appliances”
• CSA 2.41-2014 “Standard for Outdoor Decorative Gas Appliances”
• CGA 2.17-M91 (R2014), “Gas-Fired Appliances for Use at High Altitudes”
This appliance is equipped for: Natural Gas Propane.
Top of replace to combustibles: 4.0”
Top of replace opening to combustibles: 6.0”
Back of replace to back combustible wall: 0.0”
Side of replace to side wall: 0.0”
Side of replace opening to combustible trim: 4.5”
Fireplace opening to side wall in front of replace: 5.5”
Top of replace opening to combustible mantel: 17.0”
Front of replace to back combustible wall: 18.0”
Maximum depth of mantel: 12.0”
For installation on (or over) Non-Combustible Floors Only
SAMPLE
LIGHTING INSTRUCTIONS
1.On the remote control, press the “ON” button.
2.When the ames are at the high setting, press the “LOW”
button to set the ames to low
3.When the ames are at the low setting, press the “HIGH”
button to set the ames to high
TO TURN OFF GAS
1.On the remote control, press the “OFF” button.
Improper installation, adjustment, alteration, service or maintenance
WARNING
can cause injury or property damage. Refer to the owner’s information manual
provided with this appliance. For assistance, or additional information, consult a
qualied installer, service agency, or the gas supplier.
WARNING
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of
this or any other appliance.
An LP-cylinder not connected for use shall not be stored in the vicinity of this or any
other appliance.
This product has been cer tied by OMNI-Test Laboratories to ANSI Z21.97-2014/CSA 2.412014 Outdoor Decorative Gas Appliances. This appliance must be installed in accordance
with local codes, if any; if none, follow the ANSI Z223.1 standard. Inst allation and service
must be performe d by a qualied installer, service agency or the gas supplier.
EUROPEAN HOME
30 Log Bridge Road
Building 300 Suite 303
Middleton, MA 01949
tel: (781) 324-8383
Report Number: 0284GF009S
JM2LL01180913
europeanhome.com
FIGURE 4: Sample Listing Label (axed beneath the Light Panel)
A sample listing label image is shown above. A metal listing label is attached to every European Home replace and contains important
certication information. The listing label must not be removed from the replace.
JVF-M2 Series Outdoor Gas Fireplace
7
IGM2S190417
SPECIFICATIONS AND DIMENSIONS
WHEN ENCLOSING YOUR FIREPLACE THE USE OF NON-COMBUSTIBLE BUILDING
MATERIALS IS REQUIRED. PLEASE READ AND UNDERSTAND THE FOLLOWING.
COMBUSTIBLE MATERIALS
Materials that can catch re and burn are considered combustible. Any material that is made of, or faced with;
wood, wood pulp, paper, plastic or any other material that can catch re and burn is considered combustible.
Even though these materials may have been ‘ame-proofed’, made ‘re-resistant’ or are ‘re-rated’ they are
considered combustible. Standard and Type X drywall are both combustible.
NON-COMBUSTIBLE MATERIALS
A material is non-combustible when it cannot catch re and burn. For example, materials made of stone, brick,
concrete, tile, steel, plaster or glass are non-combustible.
Since this replace may be installed only outdoors, it is important to select materials that are suited for outdoor
conditions.
JVF-M2 Series Outdoor Gas Fireplace
8
IGM2S190417
CLEARANCES TO COMBUSTIBLES
CLEARANCES
MANTEL
TRIM
B
C
G
E
FIGURE 5: Clearances (Front Elevation View)
F
A
E
E
FIGURE 6: Clearances (Plan / Top View)
D
SIDEWALL
ATop of replace to ceiling of enclosure4”102 mm
BBack of replace to back combustible wall0”0 mm
CSide of replace opening to combustible trim4.5”114 mm
DFireplace opening to side wall in front of replace5.5”140 mm
ESide of replace to combustible side wall0”0 mm
FTop of replace opening to combustibles6”153 mm
GTop of replace opening to combustible mantel17”432 mm
-
JVF-M2 Series Outdoor Gas Fireplace
Maximum depth of mantel12”305 mm
9
IGM2S190417
INSTALLATION
LOCATING THE FIREPLACE
When locating your J Series Outdoor Gas Fireplace, you must ensure that the proper clearances to
combustible materials are maintained and your replace must be installed outdoors, NOT indoors. The
replace may be installed unsheltered but wind may cause a ame outage and/or excessive sooting.
If enclosed, or sheltered, the enclosure must be:
a. an enclosure with walls on all sides but NO overhead cover; or
FIGURE 7
b. a partial enclosure that includes an overhead cover but NO MORE THAN TWO side walls; or
FIGURE 8
c. a partial enclosure that includes an overhead cover and three side walls, as long as 30 percent or more of
the horizontal periphery of the enclosure is permanently open.
- 25% total area completely open.
- 30% of remaining wall area is open and unrestricted.
JVF-M2 Series Outdoor Gas Fireplace
FIGURE 9
10
IGM2S190417
Loading...