European Home J series, J-M2 Series, JVF-60-M2-S, JVF-60-M2-ST Installation, Operation And Owner's Manual

Installation,
Operation,
and
Owner’s Manual
J SERIES
Outdoor · Gas · Fireplace
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
-- Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
JVF-60-M2-S
JVF-60-M2-ST
Gas Fireplaces
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
WARNING: FOR OUTDOOR USE ONLY
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
--An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
Solid fuels shall not be burned in this appliance.
Report # 0284GF009S
JVF-M2 Series Outdoor Gas Fireplace
1
This manual is available in Canadian French upon request.
January 2019
IGM2S190417
TABLE OF CONTENTS
Important Safety Information 3 Important Safety Information About Propane 4 Specications and Dimensions 5 Clearances 9 Installation 10 Electric Installation 11 Gas Installation 13 Enclosing the Fireplace 15 Framing 16 Trim and Finish 17 Operating the Fireplace 20 Maintenance 22 Installation Record 24 Warranty 25 Appendix A: LP Installation 26
JVF-M2 Series Outdoor Gas Fireplace
2
IGM2S190417
IMPORTANT SAFETY INFORMATION
Read these instructions carefully before installing or trying to operate this gas appliance.
Thank you for purchasing a J-M2 Series Outdoor Gas Fireplace by European Home. This replace has been designed to provide you with safe, trouble-free operation.
Please read this manual thoroughly before beginning the installation of your replace. It has information which is important for safe installation and operation.
Please inspect your shipment for completeness and any damage. Contact your retailer if any damage is found. Do not install your appliance with any damaged or substituted parts.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of the appliance.
Clothing or other ammable materials should not be hung from the appliance or placed on or near the appliance.
Any guard or other protective device removed for servicing the appliance shall be replaced prior to operating the appliance. Installation and repair should be done by a qualied service person.
The appliance should be inspected before use and at least annually by a qualied service person. More frequent cleaning may be required as necessary.
It is imperative that the control compartment, burners, and circulating air passageways of the appliance are kept clean.
SOLID FUELS SHALL NOT BE BURNED IN THIS APPLIANCE
Keep the appliance area clear and free from combustible materials, gasoline, and other ammable vapors and liquids.
Do not use this appliance if any part has been under water. Immediately call a qualied service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
JVF-M2 Series Outdoor Gas Fireplace
3
IGM2S190417
IMPORTANT SAFETY INFORMATION ABOUT PROPANE (LP) GAS
This gas replace is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the optional factory-supplied conversion kit must be used.
When using propane (LP), the gas supply cylinder to be used must be:
1) constructed and marked in accordance with the U.S. Department of Transportation (D.O.T.) Specications for LP-Gas Cylinders, or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSA-B339, as applicable,
2) provided with a listed overlling prevention device, and
3) provided with a cylinder connection device compatible with the connection for the appliance.
4) If LP is hard plumbed to the replace, the propane storage tank must have a pressure regulator set for 11” w.c. (2.74 kPa).
Note
If a propane hose is used to connect a propane cylinder to the replace, the following is required:
Inspect the hose before each use of the replace.
The hose assembly must be replaced prior to the replace being put into operation if there is evidence of excessive abrasion or wear or if the hose is damaged. The replacement hose assembly must be a regulator hose with a QCC-1 connection and an outlet pressure set for 11” w.c. (2.74 kPa).
Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage.
JVF-M2 Series Outdoor Gas Fireplace
4
IGM2S190417
SPECIFICATIONS AND DIMENSIONS
SPECIFICATIONS
Model
Gas
Input Maximum Btu/hr 65,678 64,211
Input Minimum Btu/hr 49,901 48,308
Maximum Supply
Pressure
Manifold Pressure
Maximum
Manifold Pressure
Minimum
Electrical Rating V AC 120
in. w.c. 7.0 11.0
kPa 1.74 2.74
in. w.c. 5.5 10.25
kPa 1.37 2.55
in. w.c. 3.5 6.0
kPa 0.87 1.5
JVF-60-M2-S
JVF-60-M2-ST
Natural
GasLP(Propane)
Frosted Glass
Clear Glass x2 x1 Single Side x2 See-Through
Stainless Steel Wall Panels x2
Glass Capture Panel x2
8-32 Pan Head Screw x2
Left Bracket
JVF-M2 Series Outdoor Gas Fireplace
Wind Guard (Single Sided Only)
FIGURE 1
5
Right Bracket
IGM2S190417
SPECIFICATIONS AND DIMENSIONS
A
D
E
FIGURE 2: JVF-M2-60-S
F
C
B
G
D
A
F
G
B
C
E
JVF-60-M2-S
JVF-60-M2-ST
(overall width*) 69⁄” 1769 mm
A
B (viewable width) 60” 1524 mm
C (burner length) 49¼” 1251 mm D (viewable height) 17½” 444 mm E (base to opening) 7½” 190 mm
F (overall depth) 18” 457 mm
G (overall height) 28” 711 mm
*overall width does NOT include the nailing anges
FIGURE 3: JVF-M2-60-ST
UNIT WEIGHT
Pounds Kilograms
180 81.6
JVF-M2 Series Outdoor Gas Fireplace
6
IGM2S190417
SPECIFICATIONS AND DIMENSIONS
CERTIFICATION
OMNI-Test Laboratories, Inc. has certied that the J Series Outdoor Gas Fireplace meets the following standards:
• ANSI Z21.97-2014 “Standard for Outdoor Decorative Gas Appliances”
• CSA 2.41-2014 “Standard for Outdoor Decorative Gas Appliances”
• CGA 2.17-M91 (R2014), “Gas-Fired Appliances for Use at High Altitudes”
J Series Outdoor Gas Fireplace
Model: JVF-60-M2-STJVF-60-M2-S
Serial Number:
Input BTU/hr. (NG/LP): 65,000 Max. Supply Pressure (NG): 7 inches w.c. Manifold Pressure (NG): 5.5 inches w.c. Max. Supply Pressure (LP): 11 inches w.c. Manifold Pressure (LP): 10.25 inches w.c.
Electrical Rating: 120V AC, less than 2A
This appliance is equipped for: Natural Gas Propane.
Top of replace to combustibles: 4.0” Top of replace opening to combustibles: 6.0” Back of replace to back combustible wall: 0.0” Side of replace to side wall: 0.0” Side of replace opening to combustible trim: 4.5” Fireplace opening to side wall in front of replace: 5.5” Top of replace opening to combustible mantel: 17.0” Front of replace to back combustible wall: 18.0” Maximum depth of mantel: 12.0”
CLEARANCES
Orice Size (NG): 2x#39 DMS Orice Size (LP): 2x 0.064 Gas Control: Copreci
For Outdoor Use Only.
For installation on (or over) Non-Combustible Floors Only
SAMPLE
LIGHTING INSTRUCTIONS
1. On the remote control, press the “ON” button.
2. When the ames are at the high setting, press the “LOW” button to set the ames to low
3. When the ames are at the low setting, press the “HIGH” button to set the ames to high
TO TURN OFF GAS
1. On the remote control, press the “OFF” button.
Improper installation, adjustment, alteration, service or maintenance
WARNING
can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance, or additional information, consult a qualied installer, service agency, or the gas supplier.
WARNING
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
This product has been cer tied by OMNI-Test Laboratories to ANSI Z21.97-2014/CSA 2.41­2014 Outdoor Decorative Gas Appliances. This appliance must be installed in accordance with local codes, if any; if none, follow the ANSI Z223.1 standard. Inst allation and service must be performe d by a qualied installer, service agency or the gas supplier.
EUROPEAN HOME
30 Log Bridge Road
Building 300 Suite 303
Middleton, MA 01949
tel: (781) 324-8383
Report Number: 0284GF009S
JM2LL01180913
europeanhome.com
FIGURE 4: Sample Listing Label (axed beneath the Light Panel)
A sample listing label image is shown above. A metal listing label is attached to every European Home replace and contains important certication information. The listing label must not be removed from the replace.
JVF-M2 Series Outdoor Gas Fireplace
7
IGM2S190417
SPECIFICATIONS AND DIMENSIONS
WHEN ENCLOSING YOUR FIREPLACE THE USE OF NON-COMBUSTIBLE BUILDING
MATERIALS IS REQUIRED. PLEASE READ AND UNDERSTAND THE FOLLOWING.
COMBUSTIBLE MATERIALS
Materials that can catch re and burn are considered combustible. Any material that is made of, or faced with; wood, wood pulp, paper, plastic or any other material that can catch re and burn is considered combustible. Even though these materials may have been ‘ame-proofed’, made ‘re-resistant’ or are ‘re-rated’ they are considered combustible. Standard and Type X drywall are both combustible.
NON-COMBUSTIBLE MATERIALS
A material is non-combustible when it cannot catch re and burn. For example, materials made of stone, brick, concrete, tile, steel, plaster or glass are non-combustible.
Since this replace may be installed only outdoors, it is important to select materials that are suited for outdoor conditions.
JVF-M2 Series Outdoor Gas Fireplace
8
IGM2S190417
CLEARANCES TO COMBUSTIBLES
CLEARANCES
MANTEL
TRIM
B
C
G
E
FIGURE 5: Clearances (Front Elevation View)
F
A
E
E
FIGURE 6: Clearances (Plan / Top View)
D
SIDEWALL
A Top of replace to ceiling of enclosure 4” 102 mm B Back of replace to back combustible wall 0” 0 mm C Side of replace opening to combustible trim 4.5” 114 mm D Fireplace opening to side wall in front of replace 5.5” 140 mm E Side of replace to combustible side wall 0” 0 mm
F Top of replace opening to combustibles 6” 153 mm
G Top of replace opening to combustible mantel 17” 432 mm
-
JVF-M2 Series Outdoor Gas Fireplace
Maximum depth of mantel 12” 305 mm
9
IGM2S190417
INSTALLATION
LOCATING THE FIREPLACE
When locating your J Series Outdoor Gas Fireplace, you must ensure that the proper clearances to combustible materials are maintained and your replace must be installed outdoors, NOT indoors. The replace may be installed unsheltered but wind may cause a ame outage and/or excessive sooting.
If enclosed, or sheltered, the enclosure must be:
a. an enclosure with walls on all sides but NO overhead cover; or
FIGURE 7
b. a partial enclosure that includes an overhead cover but NO MORE THAN TWO side walls; or
FIGURE 8
c. a partial enclosure that includes an overhead cover and three side walls, as long as 30 percent or more of the horizontal periphery of the enclosure is permanently open.
- 25% total area completely open.
- 30% of remaining wall area is open and unrestricted.
JVF-M2 Series Outdoor Gas Fireplace
FIGURE 9
10
IGM2S190417
Loading...
+ 21 hidden pages