European Home HVF-42, HVF-60, HVF-72, HVF-42-ST, HVF-60-ST, HVF-72-ST, HVF-42-3S, HVF-60-3S, HVF-72-3S, HVF-42-STHVF-60-STHVF-72-ST, HVF-42-LC, HVF-42-RC Installation, Operation And Owner's Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
H SERIES
Vent · Free · Gas · Fireplaces
Installation,
Operation
and
Owner’s Manual
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury or loss of life.
-- Do not store or use gasoline or other
ammable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas supplier’s instructions.
Models:
HVF-42
HVF-60
HVF-72
This is an unvented gas-red heater. It
uses air (oxygen) from the room in which
it is installed. Provisions for adequate
combustion and ventilating air must be
provided. Refer to page 6.
This appliance may be installed in an
aftermarket, permanently located,
manufactured (mobile) home, where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases.
• If you cannot reach your gas supplier,
call the re department.
-- Installation and service must be performed
by a qualied installer, service agency or the
gas supplier.
H Series Vent Free Gas Fireplace EuropeanHome.com
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
February 2014
Report #284-F-07-5
1
TABLE OF CONTENTS
Important Safety Information 3
Room Volume for Vent Free 6
Specications and Dimensions 8
Pre-installation Planning 10
Rough Installation 15
Electric Installation 16
Gas Installation 18
Trim and Finish 19
Operating the Fireplace 21
Maintenance 23
Parts List 24
Warranty 26
Troubleshooting Appendix One
H Series Vent Free Gas Fireplace EuropeanHome.com
2
IMPORTANT SAFETY INFORMATION
Read these instructions carefully before installing or trying to operate this Vent Free gas heater.
PRODUCT INSTALLATION RECORD
Installer: Please complete this form. Customer: Please retain this information.
Purchased From
Date of Purchase
Installed By
Date of Installation
Fireplace Serial Number
Fuel Type NATURAL GAS
• Any change to this heater or its controls can be dangerous.
• Improper installation or use of the heater can cause serious injury or death
from re, burns, explosion or carbon monoxide poisoning.
• Do not allow fans to blow directly into the replace. Avoid any drafts that alter
burner ame patterns.
WARNING
• Do not use a blower insert, heat exchanger insert or other accessory, not
approved for use with this heater.
1. Due to high temperatures, the heater should be located out of trac and away from furniture and
draperies.
2. Children and adults should be alerted to the hazard of high surface temperature and should stay
away to avoid burns or clothing ignition.
3. Young children should be carefully supervised when they are in the same room with the heater.
4. Do not place clothing or other ammable material on or near the heater.
H Series Vent Free Gas Fireplace EuropeanHome.com
3
IMPORTANT SAFETY INFORMATION
Read these instructions carefully before installing or trying to operate this Vent Free gas heater.
5. Any safety screen or guard removed for servicing an appliance, must be replaced prior to operating
the heater.
6. Installation and repair should be done by a qualied service person. The heater should be inspected
before use and at least annually by a professional service person. More frequent cleaning may be
required due to extensive lint from carpeting, bedding material, etc. It is imperative that control
compartments, burners and circulating air passageways of the heater be kept clean.
7. To prevent malfunction and/or sooting, an unvented gas heater should be cleaned before use and at
least annually by a professional service person.
8. CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the u
with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have
the heater serviced as it may not be operating properly.
9. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54.
10. This unit was tested and listed to ANSI Z21.11.2-2011 by OMNI-Test Laboratories.
11. This appliance is approved for installation in the Commonwealth of Massachusetts. The Board of State
Examiners of Plumbers and Gas Fitters has issued approval number G1-0513-436 for this appliance.
12. Do not install this heater in a bathroom or bedroom.
13. Correct installation of the re media, proper location of the heater, and annual cleaning are
necessary to avoid potential problems with sooting. Sooting, resulting from improper installation or
operation, can settle on surfaces outside the replace. See media placement instructions for proper
installation.
14. WARNING: Avoid any drafts that alter burner ame patterns. Do not allow fans to blow directly into
replace. Do not place a blower inside burn area of rebox. Ceiling fans may create drafts that alter
burner ame patterns. Sooting and improper burning will occur.
15. Caution: Candles, incense, oil lamps, etc. produce combustion by-products including soot. Vent
Free heaters will not lter or clean soot produced by these types of products. In addition, the smoke
and/or aromatics (scents) may be reburned in the vent free heater which can produce odors. It is
recommended to minimize the use of candles, incense, etc. while the vent free heater is in operation.
H Series Vent Free Gas Fireplace EuropeanHome.com
4
IMPORTANT SAFETY INFORMATION
Read these instructions carefully before installing or trying to operate this Vent Free gas heater.
16. Keep room area clear and free from combustible materials, gasoline and other ammable vapors and
liquids.
17. This appliance is intended for supplemental heating.
18. Unvented gas heaters emit moisture into the living area. In most homes of average construction,
this does not pose a problem. In houses of extremely tight construction, additional mechanical
ventilation is recommended.
19. During manufacturing, fabricating and shipping, various components of this heater are treated with
certain oils, lms or bonding agents. These chemicals are not harmful but may produce annoying
smoke and smells as they are burned o during the initial operation of the heater; possibly causing
headaches or eye or lung irritation. This is a normal and temporary occurrence. The initial break-in
operation should last two to three hours with the burner at the highest setting. Provide maximum
ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this
initial break-in period will be slight and will disappear with continued use.
20. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. If your installation
is at an elevation greater than these, consult with the local authority having jurisdiction for gas
product installations to determine their specic requirements for high altitude installations.
21. The heater must be isolated from the gas supply piping system by closing its equipment shuto
valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than ½ psi (3.5 kPa).
22. Do not use this room heater if any part has been under water. Immediately call a qualied service
technician to inspect the heater and to replace any part of the control system and any gas control
which has been under water.
23. Never burn solid fuels in a replace where an unvented heater is installed.
24. WARNING: Any change to this heater or its controls can be dangerous.
25. When this heater is installed directly on carpeting, tile or other combustible material, other than
wood ooring, the heater shall be installed on a metal or wood panel extending the full width and
depth of the heater.
H Series Vent Free Gas Fireplace EuropeanHome.com
5
ROOM VOLUME for VENT FREE
CODES
Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which
can be obtained from…
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
or
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
ADEQUATE COMBUSTION AND VENTILATION AIR
This heater shall not be installed in a conned space or unusually tight construction unless provisions are provided for adequate
combustion and ventilation air.
The National Fuel Gas Code, (ANSI Z223.1/NFPA 54), denes a conned space as a space whose volume is less than 50 cubic feet
per 1,000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. An unconned space
is dened as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per kw) of the aggregate input
rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed,
through openings not furnished with doors, are considered a part of the unconned space.
UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE…
a) walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm (6 x
1011 kg per pa-sec-m2) or less with openings gasketed or sealed;
b) weather stripping has been added on operable windows and doors, and
c) caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and oors,
between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
This appliance is equipped for natural gas. Field conversion is not permitted.
WARNING
This heater shall not be installed in a room or space unless the required volume
of indoor combustion air is provided by the method described in the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or
WARNING
applicable local codes.
H Series Vent Free Gas Fireplace EuropeanHome.com
6
ROOM VOLUME for VENT FREE
The following formula can be used to determine the maximum heater rating (per the denition of unconned space) that is allowed in your space:
Maximum BTU/Hr. = x 1000
Example A: Consider two connecting rooms with an open area between, with the following dimensions: L1 = 15½ ft., L2 = 12 ft., W
= 12 ft., H = 8 ft.
x 1000 = 52,800 BTU/Hr.
Example B: If there were a door between the two rooms the calculation would be based only on the room with the heater.
x 1000 = 29,760 BTU/Hr.
Will my space support a H Series Vent Free Gas Fireplace?
Maximum BTU/hr. my space will support (use formula above) a) __________________
BTU/hr. of European Home H Series Vent Free Gas Fireplace b) ____37,500________
If the answer to a) is greater than b) then your space will support the installation of the H Series Vent Free Gas Fireplace; if a) is
less than b) then your space will not support an H Series Vent Free replace.
(L1 + L2)ft. x (W)ft. x (H)ft.
50
(15½ + 12)ft. x (12)ft. x (8)ft. 50
(15½)ft. x (12)ft. x (8)ft. 50
Note
Bringing in Outside (or “Make-up”) Air
Many building code jurisdictions require that outside or “make-up” air be provided when installing a replace of this type. This
requirement can be satised by the proper installation of an ‘outside air kit’ which is not provided. The nal determination of the
suitability of any particular kit must be made by the installer.
If an outside air supply is desired it should be added to the room in which the H Series Vent Free Gas Fireplace is installed, not to
the chase enclosing the replace.
If outside air is introduced into the chase, competing air pressures could compromise the operation of the replace.
H Series Vent Free Gas Fireplace EuropeanHome.com
7
26⁄”
SPECIFICATIONS and DIMENSIONS
2”
15½”
18”
5”
18”
Hearth Panel
(lifts o for service, all models)
5”
C
B
A
Figure 1. HVF-42, HVF-60, HVF-72 Fireplaces
DimensionHVF-42HVF-60HVF-72
A47”65”77”
B42”60”72”
C38”49”59”
Table 1. Dimensions by Model
H Series Burner
FuelNatural Gas ONLY
Manifold Pressure3.5” (0.87 kPa)
Minimum Supply Pressure4.0” (1.0 kPa)
Maximum Supply Pressure7.0” (1.7 kPa)
Orice Size#47 DMS
Input (High, BTU/hr.)37,500
Input (Low, BTU/hr.)25,000
Electrical120V AC 60Hz 2.5A max
Table 2. Burner Specications
H Series Vent Free Gas Fireplace EuropeanHome.com
8
SPECIFICATIONS and DIMENSIONS
CERTIFICATION
OMNI-Test Laboratories, Inc. has certied that the H Series Gas Fireplaces meet the ANSI Z21.11.2-2011
standard.
These appliances are approved for installation in the Commonwealth of Massachusetts. The Board of State
Examiners of Plumbers and Gas Fitters has issued approval number G1-0513-436 for these appliances.
H Series VENT FREE GAS FIREPLACE
Model:HVF -72HVF-60HVF-42
Serial Number: HVFS-
Max. Input BTU/hr.: 37,500
Min. Input BTU/hr.: 25,000
Max. Supply Pressure: 7 inches w.c.
Min. Supply Pressure: 4 inches w.c.
Max. Manifold Pressure: 3.5 inch w.c.
Top: 1.0” Wall face above opening: 4.0”
Rear: 0.0” Opening to side wall in front of appliance: 6.0”
Sides: 1.0” Mantel to appliance opening: 11.0”
Maximum horizontal mantel extension: 12.0”
This product has been certie d by OMNI-Test Laboratories to ANSI Z21.11.2b-2011
Unvented Heaters. This appliance must be installed in accordance with l ocal codes,
if any; if none, follow the ANSI Z223.1. Installation and service must be must be
performed by a qualied install er, service agency or the gas supplier.
This appliance shall not be eld converted.
WARNING: Do not use a blower insert, heat exchanger inser t or other accessory not
approved for use with this heater.
WARNING: Improper installation, adjustment, alteration , service or maintenance can
cause property damage, per sonal injury or loss of life. Refer to the owner’s information
manual provided with this appliance. Installation and ser vice must be performed by a
qualied installer, service agency or the gas sup plier.
This heater shall not be installed in a bedroom or b athroom.
This appliance is intended for supplemental heating.
Failure to use only parts specically approved with this heater m ay result in property
damage or personal injury. See instructi on manual for further information.
Apply loose material per instruction m anual. DO NOT apply extra material or material
not supplied with the heater. Replace only with European Home Fire Med ia approved
for H Series VENT FREE Fireplaces.
WARNING: All previously applied loose material must be removed prior to reapplication.
This appliance is equipped for Natural Gas only.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
Left and Right side are determined when facing the front of the appliance.
Orice Size: #47 DM S
Gas Control: SIT Pro ame
Electrical Rating: 120v AC, 60 Hz
2.5 A
SAMPLE
Figure 2. Sample Rating Label (axed beneath the Hearth Panel
CAUTION: Hot while in operation. Do not touch.
Severe burns may result. Keep children, clothing, furniture,
gasoline and other liquids having ammable vapors away.
WARNING:When used without adequate combustion
and ventilation air, heater may give o excessive CARBON
MONOXIDE, an odorless, poisonous gas.
DO NOT INSTALL HEATER UNTIL ALL NECESSARY PROVISIONS ARE MA DE FOR
COMBUSTION AND VENTILATION AIR . CONSULT THE WRITTEN INSTRUCTIONS
PROVIDED WITH THE HEATER FOR INFORMATION CONCE RNING COMBUSTION
AND VENTILATION AIR. IN THE ABS ENCE OF INSTRUCTIONS, RE FER TO THE
NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, AIR FOR COMBUSTION AND
VENTILATION, OR APPLICABLE LOCAL CODES.
This heater is equipp ed with a PILOT LIGHT SAFETY SYSTEM desig ned to turn o
the heater if not enou gh fresh air is available.
DO NOT TAMPER WITH THE PILOT LIGHT SAFETY SYSTEM!
If heater shuts o, do not relight until you provide fresh air. If heater keeps
shutting o, have it serviced. Keep burner and control compartment clean.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH.
Early signs of carbon monoxide poisoning resemble the ue, with headache,
dizziness and/or nausea. If you have these signs, heater may not be working
properly.
Get fresh air at once! Have heater serviced.
Some people – pregnant women, persons with heart or lung disease, anemia,
those under the inuence of alcohol, those at high altitudes – are more aected
by carbon monoxide than others.
Removal of this marking will void compliance of this heater with ANSI Z21.11.2.
manufactured by:
EUROPEAN HOME
376 Washington Street
Malden, MA 02148
Report Number: 284-F-07-5
HVFS1SLL130424
tel: (781) 324-8383
www.europeanhome.com
H Series Vent Free Gas Fireplace EuropeanHome.com
9