European Home Installation, Operation And Maintenance Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
Installation,
Operation and
Maintenance
Manual
DV 42
Gas
Fireplace
Check local codes and read all
instructions prior to installation.
XW2002
XW2004
Read and understand this manual.
Improper installation, adjustment,
alteration, service or maintenance
can cause serious injury, property
damage or even death. For
assistance or additional information
consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are
extremely hot while the fireplace is
on and remain hot even after the
fireplace has been turned off. Safety
screens are available and can reduce
the risks of severe burns. Please
keep children away from the fireplace
at all times.
®
CUS
DANGER
CAUTION
WARNING
Do not store or use gasoline or any
other flammable vapors and liquids in
the vicinity of this or any other gas
burning appliance. A fire or explosion
my occur causing serious injury,
property damage or even death.
XW2006
NOTICE
Installer: Leave this manual with the
appliance. Do not remove.
Consumer: Retain this manual for
maintenance and future reference. Do
not Discard.
XW2012
NOTICE
IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
XW2014
DV 42 Indoor Gas Fireplace
NOTICE
You must read and understand this
manual prior to installation, operation or
troubleshooting this appliance. Please
retain this owner’s manual for furure
reference and maintenance.
SIT- Nova 820 Gas Control Valve .............................................25
SIT- IPI Electronic Gas Control Valve ......................................25
Parts List ....................................................................................... 25
Appendix
A. Termination Locations ...............................................................26
B. Warranty .......................................................................................27
C. State of Massachusetts. .............................................................28
Page 2
Safety Alert Key
High voltage
Toxic
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Blank
DANGERWARNING
DV 42 Indoor Gas Fireplace
Indicates a hazardous situation which, if not
avoided, WILL result in death or serious
injury or property damage.
CAUTIONNOTICE
Indicates a hazardous situation which, if not
avoided, WILL result in minor or moderate
injury.
Introduction
INTRODUCTION
Congratulations on your purchase of a European Home
Fireplace.
European Home is committed to providing you with a gas
replace that is not only a beautiful addition to your space, but
that is also designed and manufactured to the highest safety,
reliability and engineering standards.
We strongly encourage you to read and carefully follow
the instructions laid out in this Installation, Operation and
Maintenance Manual and retain it for your future reference.
Pay special attention to all cautions, warnings, and notices
throughout this manual intended to ensure your safety.
This manual covers installation, operation and maintenance.
Lighting, operation and care of this replace can be easily
performed by the homeowner. All installation and service
work should be performed by a qualied or licensed installer,
plumber or gas tter as certied by the state, province, region
or governing body where the replace is being installed.
This installation, operation and maintenance manual is
applicable to the models described below. Refer to your rating
plate to verify included options.
WARNING
Hot glass will cause burns.
Do not touch glass until
unit is cooled. Never allow
children to touch glass.
Indicates a hazardous situation which, if not
avoided, COULD result in death or serious
injury or property damage.
Address practices that are important, but
not related to personal injury
Model
Natural Gas
Liquid Propane
Gas Rating
BTU/Hr.
Standing Pilot Ignition
SIT Electronic Ignition
DV 42XX32,000X
DV 42 EXX32,000X
The European Home warranty will be voided by, and European
Home disclaims any responsibility for, the following actions:
• Modification of the fireplace and/or components
including direct vent assembly or glass doors.
• Use of any component part not manufactured or
approved by European Home in combination with this
European Home replace system.
• Installation other than as instructed in this manual.
Consult your local gas inspection branch on installation
requirements for factory-built gas replaces. Installation and
repairs should be done by a qualied contractor.
The DV 42* direct vent replace must be installed in accordance
with these Instructions. Carefully read all the Instructions in
this manual rst. Consult the Local Gas Branch to determine
the need for a permit prior to starting the installation. It is the
responsibility of the installer to ensure this replace is installed
in compliance with the manufacturers instructions and all
applicable codes.
BEFORE YOU START:
NOTICE
Installation and repairs should be done by an
authorized gas fireplace service technician. The
appliance should be inspected before use and at
least annually by a professional. More frequesnt
cleaning may be required due to exessive lint from
carpeting, bedding material, ect. It is imperative
that control compartments, burners and circulating
air passageways of the fireplace are kept clean.
XW2016
CAUTION
Due to high operating temperatures, this appliance
should be located out of traffic & away from
furniture and draperies.
Children and adults should be alerted to the
hazards of the high surface temperature, which
could cause burns or clothing ignition.
Young children should be carefully supervised
when they are in the same room as the appliance.
Clothing or other flammable materials should not
be placed on or near the appliance.
XW2018
Installation Checklist
Determine the desired install location of your replace.
See Section 1, Dimensions on Page 5, and refer to the
Framing Section 2 for details.
Select the location of your termination and resulting
vent run.
Your selected termination location must be the highest
point in the direct vent installation.
Should it be impossible to meet the venting requirements
laid out in Section 3: Venting, please contact European
Home regarding the use of a European Home Power Vent.
Lay out the vent run; calculating the required elbows
and straight runs of flex or rigid pipe.
Layout electrical requirements. Refer to Section 4: Wiring,
for details.
Refer to Section 5: Installing the gas line, for details on
the gas connection and access.
Refer to local codes and guidelines for installation
requirements.
Installation and repairs should be done by a qualied
contractor and must conform to:
• Installations in Canada must conform to the current
CAN/CGA B-149.1 and .2 Gas Installation Code and local
regulations.
• Installations in the USA must conform to local codes,
or in the absence of local codes to the National Fuel Gas Code,
ANSI Z223.1-1988
.
• See Appendix C for installation within the State of
Massachusetts. This replace must comply with NFPA-54 Chapter
10.
DANGER
When this appliance is installed directly
on any combustible material other than
XW2020
Page 4
wood flooring, it must be installed on a
metal or wood panel extending the full
width and depth of the appliance or a
fire will occur causing serious injury,
property damage or even death.
Installation
Section 1: Installation Overview and Product Dimensions
DV 42 Indoor Gas Fireplace
Please review the Installation Checklist on Page 4 for general
information on preparing for a successful installation of your
replace.
The DV 42* replace may be installed in any location that
maintains proper clearances to air conditioning ducts, electrical
wiring and plumbing. Safety, as well as eciency of operation,
39½"
13"
5"
42"
8"
Top View
should be considered when selecting the replace location. Try
to select a location that does not interfere with room trac, has
adequate ventilation and oers an accessible path for direct
vent installation.
The replace dimensions are shown below:
3 0½"
1¼"
1¼"
1"
39½"
(Opening)
1¼"
6¼"
19"
19¾"
(Opening)
5¼"
33"
19¾"
30½"
Side ViewFront View
Figure 1. Fireplace dimensions, for ALL models shown in table on Page 3.
8"
5"
26⅝"
Page 5
DV 42 Indoor Gas Fireplace
Combustible Header,with Supplied shield.
Combustible Shelf
40 1/2”
21”
PEL
Short
90 elbow
N.G. & L.P
.
2” Min
N.G.
2” Min
12”
Max.
N.G.
37”
Combustible Header,with Supplied shield.
Combustible
Shelf
10”
Combustible Header,with Supplied shield.
Combustible Shelf
40 1/2”
21”
PEL
Short
90 elbow
N.G. & L.P
.
2” Min
Section 2: Framing
Installation
Frame in the enclosure for the unit with framing materials. The
framed opening for the assembled replace is 42" wide x 37"
high x 22⁄" deep, see Figure 2.
NOTE: When constructing the framed opening, please ensure
there is access to install the gas line when the unit is installed.
See Figure 2.
0" clearance
to corners only
42"
60⁄"
42"
84⁄"
”
37"
22⁄" or 23⁄"*
* When sheetrock is not used behind the
replace, framing depth may be reduced
by ⁄". When facing with the Overlay
Method the depth is increased by ½". See
Planning Guide for more information.
Figure 2. Framing dimensions, straight wall and corner installation.
Combustible Header,
with Supplied shield.
Combustible
Shelf
10”
L.P. & N.G
1” Min
1” Min
L.P.
Combustible Header,
with Supplied shield.
Combustible Shelf
Short
PEL
90 elbow
N.G. & L.P .
21”
40 1/2”
2” Min
Figure 5. Combustible framing for shelf over the replace, top
vent.
Clearances
When installing a shelf over the top of the replaces, the
following must be adhered to:
For Rear Vent applications, the minimum clearance is 2" from
the rear of the replace to a wall, or any combustible materials,
and 9" clearance from the top of the replace to the underside
of any combustible shelf materials.
For Top Vent applications, the minimum clearance is 2" from
the rear of the replace to a wall, or any combustible materials,
and 17½" to the underside of any combustible shelf materials.
(Minimum 2" clearance must still be maintained around the
vent pipes.)
33”
37”
Figure 3. Combustible framing for top vent, with shelf above
replace.
Combustible Header,
2” Min
N.G.
with Supplied shield.
12”
Max.
N.G.
Combustible
Shelf
10”
37”
Figure 4. Combustible framing for rear vent with shelf above the
replace.
Page 6
*
MODEL
DV 42*10"21"2"1"0"6"
European Home supplies a variety of direct venting and
termination options. The direct vent termination location
MUST be selected such that it is the highest point in the venting
assembly. It should also be selected such that it provides the
shortest vent run possible. Should it be impossible to ensure
that the termination is the highest point or to meet the venting
guidelines laid out below please contact your European Home
dealer to discuss power venting options.
Top - Rear vent
Top - Top vent
Back
Sides
Floor
Mantel
Installation
DV 42 Indoor Gas Fireplace
Section 3: Venting
NOTES FOR PLANNING VENTING:
Venting can originate from the unit through the top or through
the rear. Venting can terminate through the roof or through
an exterior wall.
Refer to Appendix A - Termination Locations to ensure the
planned termination location is acceptable.
Once the termination location has been established, refer
to the appropriate section below for installation details. All
replaces shipped from the factory are top vent. See Section
3-1 for converting the unit from top vent to rear vent.
Section 3-1: CONVERTING TO REAR VENT
Use the following instructions to convert an DV 42* for Rear
Vent use:
1. Remove the rear ue cover and gasket (5" and 8") on the
ue outlet, as shown in Figure 7.
2. Next, remove the top ue collar's (5" and 8") on the ue
outlet, as shown in Figure 7.
3. Install the (removed) rear ue cover and gasket material,
to the top vent outlet. Fasten the cover with included
hardware, as illustrated Figure 8.
4. Install the (5" and 8") collars to the rear vent outlet using
the included hardware, as illustrated Figure 8.
Framing Heat Shield
Included with the DV 42 Gas replace, is a framing heat shield
kit. This kit is fabricated from galvanized steel and arrives with
three pieces, as shown below. The shields protect all adjacent
combustible materials, mantels and mouldings from excessive
heat radiated by the replace.
NOTE: The shields must be installed as shown in Figures 6 thru 6b.
Step 1. Fasten the two side shields rst and ensure they are
fastened in place as shown. These are installed with the wide
anges facing the center of the replace opening and the shallow
ange toward inside of room. These are also fastened with nails
or screws, ush with framing as shown in Figure 6 and Inset.
INSET
Section
framing
flush with
framing
fasteners,
3-per. side
Both Side
shields typical
fireplace
5” Inner Flue Collar
8” Outer Flue Collar
Flue Gasket
Flue Cover Plate
Figure 7. Flue cover and collar removal, top vented replace.
Flue Cover Plate
Flue Gasket
8” Outer Flue Collar
5” Inner Flue Collar
Figure 6. Combustible Framing Side Heat Shield, (two pieces).
Step 2. Next, fasten the top shield, with the wide ange face
up and the shallow ange toward inside of room, Figure 6a.
fasteners,
3-pcs.
flush with
framing
fireplace
INSET
Section
framing
Top shield
Figure 6a. Combustible Framing Top Heat Shield, (one piece).
Step 3. Nail or screw the top shield in place ush with framing,
as shown in Figure 6b.
Figure 8. Flue cover and collar installation, rear vented replace.
This section applies to installations where the direct vent termination will be
roof mounted.
Section 3-2-1: VENTING LAYOUT
Selection of components and details of venting lay out should adhere to the
following:
• The maximum termination point is 32’ above the
replace (NOTE: if the maximum termination height is
used, the ame pattern may be aected).
• The vertical termination must be a minimum 2’
higher than where the termination exits the roong
materials, (asphalt shingles, cedar shakes, etc). This
distance should be measured from the high side of
the roof slope where the ue ashing intersects the
roong materials. (see Figures 11 to 11c *).
• Termination location must be a minimum 6’ from a
mechanical air inlet.
• Termination location must be a minimum 18” from a
parapet wall.
• A maximum of two osets (each oset is made up of
two 90° bends) may be made.
• Install a restop at any location where venting passes
through combustible materials and construction.
• Utilize support straps, or support plates, and rings (as
required) to meet acceptable building practices.
• Install all roof ashing and storm collars as shown.
Roof mounted Terminations.
The following details are some possible congurations for roof
mounted terminations. See below.
PVTK1
Termination
2’ min.
PVTK1
Termination
2’ min.
Support ring
32’ max.
Obstacle
Support plate
Firestop
Figure 11a. Top vent, roof mounted with 1 oset (1 oset= two
90° bends).
PVTK1
Termination
2’ min.
Support straps or
support plate & ring
Firestop
2’ max
Support plate
& ring
Support ring
32’ max.
Figure 11. Top vent, roof mounted termination with no oset in
vent run.
Support plate
Firestop
Figure 11b. Top vent, roof mounted with 2 osets (1 oset= two
Select from the following components and associated European
Home part numbers for installation of a roof mounted
termination. Use only European Home vent components. Use
of non-European Home parts will void the warranty and may
impede operation of the replace.
Connection and installation of the vent components must
adhere to the following:
• Use any combination of rigid and ex pipe as required.
• Flex sections may be stretched up to 50% of their total
length (e.g. a 24” section maybe stretched to 36”).
• Connect all vent sections using a minimum of three
sheet metal screws on the outer pipe ue.
• Ensure the pipe ends male to female slide in a minimum
of 1½” of overlap.
• Ensure all runs are supported with a minimum of 3
supports per 10’ of venting.
• When hanging/supporting venting, ensure that
1” clearance is maintained on sides and bottom of
vent runs and 2” above horizontal vent runs to any
combustible material.
• Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports.
• Place the springs, supplied with the pipe kit, between
the outer and inner pipes to keep the pipes separate
and avoid any possible hot spots.
• European Home recommends the use of a ex section
for the nal pipe connected directly to the replace
oering greater exibility of installation and absorption
of movement.
• When penetrating a combustible ceiling, a ceiling
restop must be used.
• European Home recommends that all exterior corners
and joints be sealed with exterior caulking however
we encourage you to consult your Building Envelope
Engineer or Waterproong Consultant for further
recommendations.
F - Roof FlashingPRF-7 (1/12 - 7/12 pt.)
PRF-12 (7/12 - 12/12 pt.)
Page 9