EuroMini 10V6.e Installation Manual

2x
Installation Manual
RINS1211-4
2x
Castle Care-Tech Pa g e : 3
C
ontents Page
System Overview 4
Technical Specication 5
Overview 6
The Control Panel 6 The Printed Circuit Board 7 The Tamper Spring and Connections 8
Connections 9
Transformer / Battery Connection 9 Keypad Connection 10 Reader Connection 11 Double Pole - Alarm Connections 12 Double Pole - Tamper Connections 12 DEOL: 4K7 Alarm, 2K2 Tamper 13 DEOL: 4K7 Alarm, 4K7 Tamper 13 Siren Connection 14 Speaker Connection 14 Output Connection/Example 15
Compliance Statement and Warranty 16
Compliance Statement 16 Warranty 16
Input Table Appendix 17
Page:4 Castle Care-Tech
S
ystem Overview
Inputs on main control panel
10 fully programmable inputs
Input conguration Double end of line (4K7 Alarm, 2K2 Tamper)
Double end of line (4K7 Alarm, 4K7 Tamper) Double Pole
Input Types Unused, Fire, Hold Up, 24 Hour, Intruder, Final
Exit, Entry Route, ER (FX in part), FX (ER in part), Keyswitch Latched, Keyswitch Pulsed
Programmable
Outputs
PGM, Bell, Strobe + 4 Outputs on Inputs 7,8,9 and 10 (programmed either as an input or output)
Output Types Not Used, Fire, Hold Up Any, Intruder Any, Tamper Any,
Set Fail, Entry Deviation, Siren Any, Strobe Any, Exit Starts Any, Final Set Any, Strobe Set Fail, Keyswitch Unset, Entry/Exit, Lights, Restore 1, Restore 2, PIR Latch 1, PIR Latch 2, Mains Good, Detr Indn Enable, Follow Test, Off During Test, Detr Walk Test, Mains Fail, Battery Fault, Low Volts, Global Fault 1, Global Fault 2, Engineer Access
Keypad Contemporary LCD Keypad 32 Character
Number of Keypads 4
Arming Options Timed, Final Door, Timed/Final
User Codes 30 user codes, 1 Master Manager, 1 Engineer
Logs 500 Mandatory, 200 Optional
Fuses AUX, Bell, RS485 Bus, Battery
Tampers Case Tamper and Siren Tamper
Castle Care-Tech Pa g e : 5
T
echnical Specication
Electrical Specication
Supply Voltage (A.C.) 18VAC Nominal (+-20%), 50Hz (+-10%) Supply Voltage (D.C.) 12VDC Nominal (10-15 Volt DC Range)
Power Supply 1A Regulated
Supply Current <80mA Quiescent (DC supply, no active outputs)
Internal battery charger
800mA continous, 13.68V nominal (fold-back current limited)
Battery supply protection Reverse polarity protected
Battery nal disconnect
voltage
10.5V
Zone inputs
0-20V, normally closed, normally open, double balanced circuits
PGM/SAB outputs Switched negative 1Ah (max)
Shared PGM outputs Switched negative 50mA (max)
SAB/AUX supply fuses 800mA quick-blow
Battery reverse
protection fuse
1.6A slow-blow
Mains Fuse Mains Fuse - Anti-Surge 315mA
Physical/Mechanical Specication
Dimensions 250 x 297 x 82mm
Weight 3.07 kilos
Environmental Specication
Operational temperature
range
-20°C to +60°C
Storage temperature
range
-20°C to +60°C
Electrical Rating: 1A. EN50131-6:1997 rating: 875mA when used in Grade 1 system, 465mA when used in Grade 2 system
Battery recommend 3Ah or 7Ah (Max)
Page:6 Castle Care-Tech
O
verview
Control Panel
The EURO mini is already fully assembled in a metal case. The diagram below shows a basic overview of the different components.
To Mains Supply
Battery Holder
3Ah or 7Ah Battery
Cable Entry Holes
Wall Fixing Holes
Mains Transformer
Neutral
Live
Fuse carrier handle
Mains Fuse Anti-Surge: 315mA
Earth
Main Cable Entry Hole
Z1 GND Z2 GND +12V Z3 GND Z4 Z5 GND Z6 GND +12V Z7 GND Z8 Z9 GND Z10 D1- D2+ D3 D4 - BAT + GND
BELL
BUS
BATTERY
AUX
PGM AUX+ SPK STB BELL TR B- B+
Remove for DP
The Control Panel