Euromex IS.1152-EPL, IS.1153-PLPH, IS.1153-EPL, IS.1152-PLPH, IS.1152-EPLi User Manual

...
euromex microscopen bv The Netherlands
Page 1
Models Bino Trino
EWF 10x
20 mm
EWF 10x
22 mm
E-Plan
objectives
Plan Phase objectives
E-Plan IOS
objectives
Plan IOS
pbjectives
Plan Phase
IOS
objectives
Mechanical
rackless
stage
iCare
sensor
Köhler
LED
IS.1152-EPL
IS.1153-EPL IS.1152-PLPH IS.1153-PLPH IS.1152-EPLi IS.1153-EPLi IS.1152-PLi IS.1153-PLi IS.1152-PLPHi IS.1153-PLPHi
The iScope series has been designed with all kind of Life Sciences applications and great durability in mind. This resulted in a modern, robust and high level microscope for everyday use, equipped with excellent optical and mechanical components. Specific attention to production methods resulted also in an excellent price/performance ratio
Models
Objectives
(1) optional objectives (2) oil immersion objectives
Page 2
Eyepiece
Objective
Magnification
10x
4x
40x
10x
10x
100x
10x
40x
400x
10x
60x
600x
10x
100x
1000x
The S40x, S60x and S100x objectives are equipped with a spring mount, to prevent damage to the front lens and the slide.
The Numeric Aperture - N.A. – of the objective is an indication for the resolving power of the objective.
The total magnification can be calculated by multiplying the magnification of the eyepiece with the magnification of the objective. The magnifications are displayed in the table below:
Page 3
A
B
D
E F G
J
I
H
K
L
M C N
O
Construction of the microscope
The names of the several parts are listed below and are indicated in the picture:
A) Microscope head N) Slide protection handle B) Eyepieces O) Height adjustment condenser C) Diopter adjustment I) Kohler iris diaphragm D) Nosepiece J) Collector lens E) Objectives K) iCare sensor F) Stage with X-Y mechanical stage L) Light intensity adjustment knob G) X-Y stage controls M) Coaxial coarse adjustment H) Condenser with iris diaphragm I) Kohler iris diaphragm J) Collector lens
Page 4
A
B
C
D
X
E F
G
H
I
Preparing the iScope microscope for use
Your microscope is a delicate product, please handle it with care.
Carefully remove the items from their packing and place them on a flat, firm surface. Please do not expose the microscope to direct sun light, high temperatures, damp, dust or acute shake. Please make sure the worktable is flat and horizontal.
When moving the microscope, use the left hand to hold the transport handle at the backside of the microscope and with the right hand the bottom of the microscope.
Transport handle
Caution! Holding the microscope with the stage, the stage focusing knob will damage the microscope.
Insert the power cord in the backside of the microscope and use the cable storage CSS - Cable Storage System – to store the cable after use
CSS - Cable Storage System
Caution! If the bacterial solution or water splatters over the stage, objective or head, pull out the power cord immediately and dry the microscope.
For safety reasons, make sure the power switch is turned off and remove the plug before
Page 5
replacing the led unit or fuse
Assembling Steps
Euromex Microscopes will always try to keep the number of assembly steps for their customers as low as possible but in some cases there are some steps to be taken. The steps mentioned below are often not necessary but described for your convenience nonetheless.
Mounting the objectives
1. Rotate the coarse focusing knob to lower the stage to the lowest position.
2. Install the objectives into the objective nosepiece from the lowest magnification to the highest in a clockwise direction from the rear side of the microscope. When using the microscope, start using the low magnification objective (4X or 10X) to search for specimen and focus, and then continue with high magnification objective to observe.
The microscope head
The standard iScope series configuration is supplied with the head assembled. However, if your order contains the fluorescence it should be mounted first. The dovetail on the bottom side of these parts fits into the slot on the top side of the other parts.
Placing the eye pieces
1. Remove the cover of eyepiece tube.
2. Insert the eyepiece into the eyepiece tube
The eyeshades
Each eyepiece has its rubber eyeshade. This prevents damage to the lens, and prevents stray light. The eyeshade can simply be slipped over the eyepiece.
Connecting the power cord
The iScope series microscopes supported a wide range of operating voltages: 100 to 240V. Please use a grounded power connection.
1. Make sure the power switch is off before connecting.
2. Insert the connector of power cord into the iScope power socket, and make sure it
connects well.
3. Insert the other connector into the mains socket, and make sure it connects well.
Don’t use bend or twist the power cord, it will get damaged. Using the special cord supplied by Euromex. If it’s lost or damaged, choose one with the same specifications.