EUROM B950I, B1000i, B2000i, B3000i User Manual

User manual
B950I, B1000i, B2000i, B3000i
Page 20
Never use the generator in a closed room/area. Exhaust may cause suffocation.
The exhaust pipe becomes very hot during operation. Do not touch the exhaust pipe after use.
Only use approved cables.
Fuel is very flammable, be careful when filling with gasoline. Do not fill when you are close to open
fire, lighted cigarettes, sparks or similar. Always clean up spilled gasoline.
Standby power generators for buildings must only be connected by an authorised electrician, who must comply with the regulations in question. Incorrect connection can make the power/electricity run back to the generator. This can cause an electric shock if a person gets in contact with the generator. After the power has been restored the generator may explode, burn or cause a burn in the electric system.
Always inspect all connections before you start the machine. This can prevent an accident.
Always place the generator 1 meter away from buildings or other equipment during operation.
Only use the generator on a horizontal surface.
Draw attention to how the generator is to be stopped and understand all its functions. Never leave
the use of the generator to persons who has not received any instruction about the operation.
Keep children away from the generator during operation.
Using the generator with wet hands may lead to electric shock.
Never use the generator in rain or snow. Always make sure that the generator does not become
wet.
NOTE If you are going to use the generator in thin statums of air, higher than 1500 meter above water
surface you shall contact your dealer for guidance.
Page 21
1. Contents
1. Contents...........................................................................................................................................21
2. Identification of components ...............................................................................................................22
3. Automatic current control (SMART)..................................................................................................... 22
4. Before start - Oil ................................................................................................................................23
4.1. Before start - gasoline .................................................................................................................24
4.2. Before start - air filter................................................................................................................... 24
5. Start .................................................................................................................................................25
6. Operation of the generator .................................................................................................................27
6.1. Alternating current ......................................................................................................................27
6.2. Indicators ...................................................................................................................................28
6.3. Direct current..............................................................................................................................28
6.4 Oil warning..................................................................................................................................30
6.5 Stop ...........................................................................................................................................30
7. Maintenance ....................................................................................................................................31
7.1 Changing oil................................................................................................................................ 31
7.2 Air filter .......................................................................................................................................32
7.3 Spark plug ..................................................................................................................................33
8. Transport and storage........................................................................................................................ 33
9. Specifications.................................................................................................................................... 35
10. Trouble shooting.............................................................................................................................. 36
Spare parts
Part list and explosive drawings for the specific product, please contact your
dealer.
If you help find part numbers yourself, it will ease the service.
For purchase of spare parts, please contact your dealer.
Page 22
2. Identification of components
3. Automatic current control (SMART)
The engine speed is automatically adjusted, when the current is disconnected. The same way the speed goes up when you connect the current. This ensures the fuel consumption being held at a minimum.
Warning - The automatic regulation does not work effectively if an even electric current is needed.
Warning - When the generator is to produce a heavy, even current you shall place the switch in
the OFF position in order to reduce changes in the current.
Warning - When you work with DC (Direct Current), always place the switch in the OFF position.
Choker
Cover
Starter
Engine switch
Control panel Fuel cap
Fuel cap cent lever
Cover for fuse
Muffler DC
Smart contact
Smart-Throttle switch
Over load indicator
Ground Oil indicator
AC
DC circuit Switch
Page 23
4. Before start - Oil
NOTE
- Always inspect the generator on a horizontal surface with a turned-off engine.
- The in-built alarm system will automatically stop the engine before the oil level drops under the
approved level. In order to avoid unpredicted disconnection you shall check the oil level regularly.
- Using the generator with too little oil can cause severe damages to the wear parts of the engine.
Use full-synthetic premium 4-stroke oil, which meets the demands in question.(API) Loosen the screws that tighten the plate on the backside of the generator and remove the plate. Check the oil level by removing the oil stick, clean it with a dry clean cloth. Insert the oil stick without screwing it in. See the oil level on the stick. Fill with oil if necessary. Oil capacity: 0,25/0,40 L.
Oliepind
Fill oil until here Screw
Left maintenance cover
Air cleaner cover
Oil stick
Oil filler hole
Page 24
4.1. Before start - gasoline
Use regular unleaded 95 octane gasoline. Avoid getting dust, dirt or water in the tank. After filling, fasten the tank cover securely. Only fill fuel to the indicated marking (see figure below).
4.2. Before start - air filter
Check that the air filter is clean and in good shape.
PROCEDURE
Loosen the screws that fasten the plate on the backside of the generator and remove the plate. On the top of the air filter a tap is placed, press this down and the air filter is loosened. Check the filter and clean it, replace if necessary.
WARNING
Never use the generator without an air filter. This will result in dirt being drawn into the carburettor of the engine.
NOTE
- By transport you always turn the upper part of the gasoline cover to the ”OFF” position.
Fill untill here
Fuel cap
Fuel cap
Loading...