Euro-Line ADR522CW, AE522SC, AE522SC3, AER522SCL3, ADR522HW Technical & Service Manual

...
ADR522CW AE522SC AE522SC3 / AER522SCL3
ADR522HW AE522HS AE522HS3 / AER522HS3
OUTDOOR UNIT
0.8180.225.0
SPLIT SYSTEM AIR CONDITIONER
OCTOBER 01
TECHNICAL & SERVICE MANUAL
®
TABLE OF CONTENTS
OPERATIONS.................................................................................................................PAGE.....1
ELECTRIC WIRING DIAGRAM.....................................................................................................31
H
H
A
SPECIFICATIONS..........................................................................................................................9
B
MAJOR COMPONENT SPECIFICATIONS................................................................ .................15
C
DIMENSIONALE DATA.................................................................................................................21
E
FUNCTION.....................................................................................................................................23
F
REFRIGERANT FLOW DIAGRAM................................................................................................29
G
TROUBLESHOOTING HEATING MODEL....................................................................................34
I
SAME PARTS OF AIR CONDITIONER DO NOT OPERATE........................................................41
L
AIR CONDITIONER OPERATES,BUT ABNORMALITIES OCCUR.............................................44
M
TROUBLESHOOTING COOLING MODEL....................................................................................45
N
SAME PARTS OF AIR CONDITIONER DO NOT OPERATE.......................................................52
O
AIR CONDITIONER OPERATES,BUT ABNORMALITIES OCCUR............................................53
P
CHECKING ELECTRICAL COMPONENTS.................................................................................56
Q
OTHERS COMPONENTE SPECIFICATIONS..............................................................................15
D
Function Temperature
Maximum 35°C DB / 22°C WB 46°C DB Minimum 19°C DB / 14°C WB,5 19°C DB
Indoor air intake temp. Outdoor air intake temp.
Cooling
Maximum 27°C DB / 19°C WB 24°C DB / 18°C WB Minimum – DB / – WB,5 –8°C DB / –9°C WB
Heating
A
OPERATING RANGE
1
Maximum 35°C BS / 22°C BU 50°C BS Minimum 19°C BS / 14°C BU,5 -15°C BS
Referred to the systems -ADR522CW - AER522SCL3 only (3 phase and low ambient version)
INDOOR UNIT OUTDOOR UNIT
Indoor air Outdoor air
Function Temperature
intake temp. intake temp.
Cooling
Shipping weight (approx.) kg 53 79
UNIT MODEL
Shipping volume m
3
0.44 0.37
2
Data subject to change without notice.
NOTA.Rating conditions:
Cooling:Outside air temp.: 35°C DB, indoor unit entering air temp.: 27°C DB / 19°C WB Heating:Outside air temp.: 7°C DB / 6°C WB, indoor unit entering air temp.: 20°C DB
Power source 220 / 230 / 240V - 1 - 50 Hz
W (Kcal/h) 6.300 (5.418)
B
SPECIFICATIONS
1)UNIT SPECIFICATIONS
INDOOR UNIT OUTDOOR UNIT
ADR522CW
AE522SC
BTU/h 21.500
Air circulation (high - med - low) m
3
/h 1200 External static pressure (high speed)mm w.g. (Pa) 5 (49) at shipment - 10 (98) using the Booster cable Moisture removal l/h 2.8
Voltage rating V 230 Available voltage range V 198 ÷264 Running ampere A 12.5 Power input W 2.600 Power factor % 90 Compressor locked rotor amperes A 70 C.O.P. W/W 2,42
Controls Microprocessor Control unit Remote control Temperature control I.C. thermostat Timer ON/OFF 12 hours Fan speed indoor / outdoor 3 and auto / 2 auto Air filter Washable, easy access Compressor Rotary (hermetic) Refrigerant / ref. control / amount charged at shipg R22 / capillary tube / 2,5 g
Max. tubing length m (with factory R22 charge) 10
Required amount of additional refrigerant g/m 25
Max. allowable tubing length m (with R22 addition) 20
Accessory Booster cable
Higth mm 316 835 Width mm 1050 850 Depth mm 665 305 Net weigth kg 51 70
Operation sound
Indoor Hi / Me / Lo (1 m) dB-A Outdoor Hi / Lo (3 m) dB-A
38 / 33 / 29
55 / 52
Refrigerant tube diameter
Narrow tube mm (in.) Wide tube mm (in.)
6,35 (1/4”)
15.88 (5/8”)
Limit of elevation difference
m
between the two units
7
Umidità asportata (alta velocità) l/h 0,9
PERFORMANCES COOLING
DIMENSIONS AND WEIGTH INDOOR UNIT OUTDOOR UNIT
Capacity
ELECTRICAL RATINGS
FEATURES
Shipping weight (approx.) kg 53 79
3
UNIT MODEL
Shipping volume m
3
0.44 0.37
Data subject to change without notice.
NOTA.Rating conditions:
Cooling:Outside air temp.: 35°C DB, indoor unit entering air temp.: 27°C DB / 19°C WB Heating:Outside air temp.: 7°C DB / 6°C WB, indoor unit entering air temp.: 20°C DB
Power source 400V - 3N - 50 Hz (4 wires)
W (Kcal/h) 6.000 (5.160)
1)UNIT SPECIFICATIONS
INDOOR UNIT OUTDOOR UNIT
ADR522CW
AE522SC3
BTU/h 20.400
Air circulation (high - med - low) m
3
/h 1200 External static pressure (high speed)mm w.g. (Pa) 5 (49) at shipment - 10 (98) using the Booster cable Moisture removal l/h 2.8
Voltage rating V 400 Available voltage range V 342 ÷440 Running ampere A 4.6 Power input W 2.500 Power factor % 80 Compressor locked rotor amperes A 28 C.O.P. W/W 2.4
Controls Microprocessor Control unit Remote control Temperature control I.C. thermostat Timer ON/OFF 12 hours Fan speed indoor / outdoor 3 and auto / 2 auto Air filter Washable, easy access Compressor Rotary (hermetic) Refrigerant / ref. control / amount charged at shipg R407c / capillary tube / 2.38 g
Max. tubing length m (with factory R22 charge) 10
Required amount of additional refrigerant g/m 25
Max. allowable tubing length m (with.R22.addition))...................20
Accessory Booster cable
Higth mm 316 835 Width mm 1050 850 Depth mm 665 305 Net weigth kg 51 70
Operation sound
Indoor Hi / Me / Lo (1 m) dB-A Outdoor Hi / Lo (3 m) dB-A
38 / 33 / 29
51 / 44
Refrigerant tube diameter
Narrow tube mm (in.) Wide tube mm (in.)
6,35 (1/4”)
15.88 (5/8”)
Limit of elevation difference
m
between the two units
7
Umidità asportata (alta velocità) l/h 0,9
PERFORMANCES COOLING
DIMENSIONS AND WEIGTH INDOOR UNIT OUTDOOR UNIT
Capacity
ELECTRICAL RATINGS
FEATURES
Shipping weight (approx.) kg 53 79
4
UNIT MODEL
Shipping volume m
3
0,44 0,37
Data subject to change without notice.
NOTA.Rating conditions:
Cooling:Outside air temp.: 35°C DB, indoor unit entering air temp.: 27°C DB / 19°C WB Heating:Outside air temp.: 7°C DB / 6°C WB, indoor unit entering air temp.: 20°C DB
Power source 400V - 3N - 50 Hz (4 wires)
W (Kcal/h) 6.150 (5,335)
1)UNIT SPECIFICATIONS
INDOOR UNIT OUTDOOR UNIT
ADR522CW
AER522SCL3
BTU/h 21.000
Air circulation (high - med - low) m
3
/h 1200 External static pressure (high speed)mm w.g. (Pa) 5 (49) at shipment - 10 (98) using the Booster cable Moisture removal l/h 2,8
Voltage rating V 400 Available voltage range V 342 ÷440 Running ampere A 4.8 Power input W 2.800 Power factor % 85 Compressor locked rotor amperes A 28 C.O.P. W/W 2,2
Controls Microprocessor Control unit Remote control Temperature control I.C. thermostat Timer ON/OFF 12 hours Fan speed indoor / outdoor 3 and auto / 2 auto Air filter Washable, easy access Compressor Rotary (hermetic) Refrigerant / ref. control / amount charged at shipg R407c / capillary tube / 2.410 g
Max. tubing length m (with factory R407c charge) 10
Required amount of additional refrigerant g/m 25
Max. allowable tubing length m ...(with.R407c.addition)....................30
Accessory Booster cable
Higth mm 316 835 Width mm 1.050 850 Depth mm 665 305 Net weigth kg 51 70
Operation sound
Indoor Hi / Me / Lo (1 m) dB-A Outdoor Hi / Lo (3 m) dB-A
38 / 33 / 29
55 / 52
Refrigerant tube diameter
Narrow tube mm (in.) Wide tube mm (in.)
6,35 (1/4”)
15,88 (5/8”)
Limit of elevation difference
m
between the two units
7
Umidità asportata (alta velocità) l/h 0,9
PERFORMANCES COOLING
DIMENSIONS AND WEIGTH INDOOR UNIT OUTDOOR UNIT
Capacity
ELECTRICAL RATINGS
FEATURES
Shipping weight (approx.) kg 53 79
5
UNIT MODEL
Shipping volume m
3
0,44 0,37
Data subject to change without notice.
NOTA.Rating conditions:
Cooling: Outside air temp.: 35°C DB, indoor unit entering air temp.: 27°C DB / 19°C WB Heating: Outside air temp.: 7°C DB / 6°C WB, indoor unit entering air temp.: 20°C DB
Power source 220 / 230 / 240V - 1 - 50 Hz
W (Kcal/h) 6.100 (5246) 7.450 (6.407)
1)UNIT SPECIFICATIONS
INDOOR UNIT OUTDOOR UNIT
ADR522HW
AE522SH
BTU/h 20.800 25400
Air circulation (high - med - low) m
3
/h 1200 External static pressure (high speed)mm w.g. (Pa) 5 (49) at shipment - 10 (98) using the Booster cable Moisture removal l/h 2,8
Voltage rating V 264 Available voltage range V 198 ÷264 Running ampere A 12 13.6 Power input W 2.650 2.970 Power factor % 96 95 Compressor locked rotor amperes A 70 C.O.P. W/W 2.3 2.5
Controls Microprocessor Control unit Remote control Temperature control I.C. thermostat Timer ON/OFF 12 hours Fan speed indoor / outdoor 3 and auto / 2 auto Air filter Washable, easy access Compressor Rotary (hermetic) Refrigerant / ref. control / amount charged at shipg R22 / capillary tube / 2.28 g
Max. tubing length m (with factory R22 charge) 10
Required amount of additional refrigerant g/m 25
Max. allowable tubing length m ...(with.R22.addition).....................30
Accessory Booster cable
Higth mm 316 835 Width mm 1.050 850 Depth mm 665 305 Net weigth kg 51 70
Operation sound
Indoor Hi / Me / Lo (1 m) dB-A Outdoor Hi / Lo (3 m) dB-A
38 / 33 / 29
55 / 52
Refrigerant tube diameter
Narrow tube mm (in.) Wide tube mm (in.)
6,35 (1/4”)
15,88 (5/8”)
Limit of elevation difference
m
between the two units
7
Umidità asportata (alta velocità) l/h 0,9
PERFORMANCES COOLING HEATING
DIMENSIONS AND WEIGTH INDOOR UNIT OUTDOOR UNIT
Capacity
ELECTRICAL RATINGS
FEATURES
Shipping weight (approx.) kg 53 79
UNIT MODEL
Shipping volume m
3
0.44 0.37
6
Data subject to change without notice.
NOTA.Rating conditions:
Cooling:Outside air temp.: 35°C DB, indoor unit entering air temp.: 27°C DB / 19°C WB Heating:Outside air temp.: 7°C DB / 6°C WB, indoor unit entering air temp.: 20°C DB
Power source 400V - 3N - 50 Hz (4 wires)
W (Kcal/h) 5.800 (4.988) 7.300 (6.278)
1)UNIT SPECIFICATIONS
INDOOR UNIT OUTDOOR UNIT
ADR522HW
AE522SH3
BTU/h 20.000 25.000
Air circulation (high - med - low) m
3
/h 1200 External static pressure (high speed)mm w.g. (Pa) 5 (49) at shipment - 10 (98) using the Booster cable Moisture removal l/h 2.8 ----
Voltage rating V 400 Available voltage range V 342 ÷440 Running ampere A 4.5 4.8 Power input W 2.650 2.900 Power factor % 93 94 Compressor locked rotor amperes A 28 C.O.P. W/W 2,36 2,73
Controls Microprocessor Control unit Remote control Temperature control I.C. thermostat Timer ON/OFF 12 hours Fan speed indoor / outdoor 3 and auto / 2 auto Air filter Washable, easy access Compressor Rotary (hermetic) Refrigerant / ref. control / amount charged at shipg R22 / capillary tube / 2,46 g
Max. tubing length m (with factory R22 charge) 10
Required amount of additional refrigerant g/m 25
Max. allowable tubing length m (with R22 addition) 20
Accessory Booster cable
Higth mm 316 835 Width mm 1050 850 Depth mm 665 305 Net weigth kg 51 70
Operation sound
Indoor Hi / Me / Lo (1 m) dB-A Outdoor Hi / Lo (3 m) dB-A
38 / 33 / 29
55 / 52
Refrigerant tube diameter
Narrow tube mm (in.) Wide tube mm (in.)
6,35 (1/4”)
15.88 (5/8”)
Limit of elevation difference
m
between the two units
7
Umidità asportata (alta velocità) l/h 0,9
PERFORMANCES COOLING HEATING
DIMENSIONS AND WEIGTH INDOOR UNIT OUTDOOR UNIT
Capacity
ELECTRICAL RATINGS
FEATURES
Shipping weight (approx.) kg 53 79
UNIT MODEL
Shipping volume m
3
0.44 0.37
7
Data subject to change without notice.
NOTA.Rating conditions:
Cooling:Outside air temp.: 35°C DB, indoor unit entering air temp.: 27°C DB / 19°C WB Heating:Outside air temp.: 7°C DB / 6°C WB, indoor unit entering air temp.: 20°C DB
Power source 400V - 3N - 50 Hz (4 wires)
W (Kcal/h) 5.700 (4.902) 7.400 (6.364)
1)UNIT SPECIFICATIONS
INDOOR UNIT OUTDOOR UNIT
ADR522HW
AER522SH3
BTU/h 19.500 26.000
Air circulation (high - med - low) m
3
/h 1200 External static pressure (high speed)mm w.g. (Pa) 5 (49) at shipment - 10 (98) using the Booster cable Moisture removal l/h 2.8 -----
Voltage rating V 400 Available voltage range V 342 ÷440 Running ampere A 4.8 5 Power input W 2.750 3.000 Power factor % 83 86 Compressor locked rotor amperes A 28 C.O.P. W/W 2.1 2.5
Controls Microprocessor Control unit Remote control Temperature control I.C. thermostat Timer ON/OFF 12 hours Fan speed indoor / outdoor 3 and auto / 2 auto Air filter Washable, easy access Compressor Rotary (hermetic) Refrigerant / ref. control / amount charged at shipg R407c / capillary tube / 2,40 g
Max. tubing length m (with factory R407c charge) 10
Required amount of additional refrigerant g/m 25
Max. allowable tubing length m (with R407c addition) 20
Accessory Booster cable
Higth mm 316 835 Width mm 1050 850 Depth mm 665 305 Net weigth kg 51 70
Operation sound
Indoor Hi / Me / Lo (1 m) dB-A Outdoor Hi / Lo (3 m) dB-A
39/ 33 / 29
55/ 52
Refrigerant tube diameter
Narrow tube mm (in.) Wide tube mm (in.)
6,35 (1/4”)
15.88 (5/8”)
Limit of elevation difference
m
between the two units
7
Umidità asportata (alta velocità) l/h 0,9
PERFORMANCES COOLING HEATING
DIMENSIONS AND WEIGTH INDOOR UNIT OUTDOOR UNIT
Capacity
ELECTRICAL RATINGS
FEATURES
Fase area m
2
0.125
8
µF 5
VAC 440
Fin pitch mm 1.8
Voltage AC 230V - 50 Hz Input 114.7 W
Rated
UNIT MODEL ADR522CW/ADR522HW
REMOTE CONTROL UNIT RCS-U186QH CONTROLLER P.C.B. POW-U226QH
FAN Centrifugal
EXTERNAL FINISH
Open °C 130 ±18 Close °C 179 ±15
Coil Aluminum plate fin / Copper tube
d)INDOOR UNIT
Power source 220 / 230 / 240V -1 - 50 Hz
Controls Microprocessor
Number ... dia. / length mm 2 ...
Ø200 / L 230
Control circuit fuse 250V - 3A
Model ... Number K48415M01535 ... 1 Power source V 220 / 230 / 240-1-50 Hz No. di poli ... giri/min (230V-max) 4 ... 800 Nominal output W 65
WHT - BRN:181,1
ORG - VLT:136,8 YEL - ORG:151,4
BLK - YEL:120,6
WHT - VLT:112,7
VLT - PNK:144,2
Coil resistance (Ambient temp. 20°C)
SAFETY DEVICES
Internal type
Operating temp.
Model PC
Total head capacity 0.4 m / 0.6 l/m
Run capacitor
Rows 2
Insulated galvanized metal sheet
HEAT EXCHANGER
DRAIN PUMP
FAN MOTOR
C
MAJOR COMPONENT SPECIFICATIONS
9
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Controller PCB POW–C226GH
Type Rotary (Hermetic) Compressor model C–R221H5S 80687145B Nominal output W 2,200 Compressor oil ... Amount cc 4GSD–T or SAY-56T ... 1,350 Coil resistance (Ambient temp. 25°C) C – R : 0.78
C – S : 2.41
Type Internal protector External protector (OLR)
Safety
Overload relay OL–D24
devices Operating temp. Open °C Automatic opening 150 ± 5
Close °C Automatic reclosing 63 ± 11
Operating amp.(Ambient temp. 25°C) — Trip in 6 to 16 sec. at 59 A
Run capacitor µF 40.0
VAC 450 Crank case heater 240V 30W Type Propeller Number ... Dia. mm 1 ... ø 460 Fan motor model ... Number Smen 19TFB6064 ... 1 No. of poles ... rpm (230 V, High) 6 ... 836 Nominal output W 50
Coil resistance (Ambient temp. 20°C) WHT – BRN : 99.5 ± 7%
WHT – YEL : 252.0 ± 7%
WHT – PNK : 63.2 ± 7%
Safety
Type Thermal protector
devices Operating temp. Open °C 130 ± 5
Close Automatic reclosing
Run capacitor µF 5.0
VAC 440 Coil Aluminum plate fin / Copper tube Rows 2 Fin pitch mm 2.0 Face area m
2
0.610
External Finish Acrylic baked-on enamel finish
Heat
Exch. Coil
CompressorFan & Fan Motor
Outdoor Unit AE522SH
Power source Control circuit
CONTROLLER PCB COMPRESSOR
T
yp
e
Com
p
ressor model Source Nominal out
p
ut W
Com
p
ressor oil ... Amount cc
C - R
C - S
R - S
Safety devices: T
ype
Internal protecto
r
External protecto
r
Overload rela
y
/
/
HOE-10TB TH-7A
O
p
en °CAutomatic openin
g
//
Close °CAutomatic reclosin
g
//
Operating amp. (Ambient temp. 25°C
)
/
/7A
µ
F
VAC
Crank case heater
FAN AND FAN MOTO
R
Type Number ... Dia. mm Fan motor model ... Number Source No. of
p
oles ... rpm (220 V
)
Nominal output W
WHT - BRN
WHT - YEL
Safety devices: T
ype
Open °C Close
µ
F
VAC
HEAT EXCH. COIL
Coil Rows Fin
p
itch mm
Face area
m
2
EXTERNAL FINISH
A
crylic baked-on enamel finish
Data subject to change without notice.
380 - 400 V - 3N ~ 50 H
z
220 - 240 V ~ 50 H
z
POW-C226GH
Rotar
y (
Hermetic
)
380 - 400 V - 3N ~ 50 H
z
/
/
Run capacitor
/
/
240 V - 30 W
Propelle
r
Internal protecto
r
130 ± 8
Operating temp.
A
utomatic reclosin
g
1 ... Ø460
Smen 19TFB6064 ... 1
220 - 240 V ~ 50 H
z
6 ... 840
50
Run capacitor
5
440
99,5
252,0
63,2
Coil resistance (Ambient temp. 20°C)
Operating temp.
Coil resistance (Ambient temp. 25°C) 4,64
4,88
C-R223H8S-806-871-88B
2200
SUNISO4CS ... 1350
4,97
A
luminum plate fin / Copper tube
0,61
2
2
10
WHT - PNK
Outdoor Unit AE522SH3
Power source Control circuit
CONTROLLER PCB COMPRESSOR
T
yp
e
Com
p
ressor model Source Nominal out
p
ut W
Com
p
ressor oil ... Amount cc
C - R
C - S
R - S
Safety devices: T
ype
Internal protecto
r
External protecto
r
Overload rela
y
/
/
HOE-10TB TH-7A
O
p
en °CAutomatic openin
g
//
Close °CAutomatic reclosin
g
//
Operating amp. (Ambient temp. 25°C
)
/
/7A
µ
F
VAC
Crank case heater
FAN AND FAN MOTO
R
Type Number ... Dia. mm Fan motor model ... Number Source No. of
p
oles ... rpm (220 V
)
Nominal output W
WHT - BRN
WHT - YEL
Safety devices: T
ype
Open °C Close
µ
F
VAC
HEAT EXCH. COIL
Coil Rows Fin
p
itch mm
Face area
m
2
EXTERNAL FINISH
A
crylic baked-on enamel finish
Data subject to change without notice.
380 - 400 V - 3N ~ 50 H
z
220 - 240 V ~ 50 H
z
POW-C226GH
Rotar
y (
Hermetic
)
380 - 400 V - 3N ~ 50 H
z
/
/
Run capacitor
/
/
240 V - 30 W
Propelle
r
Internal protecto
r
130 ± 8
Operating temp.
A
utomatic reclosin
g
1 ... Ø460
Smen 19TFB6064 ... 1
220 - 240 V ~ 50 H
z
6 ... 840
50
Run capacitor
5
440
99,5
252,0
63,2
Coil resistance (Ambient temp. 20°C)
Operating temp.
Coil resistance (Ambient temp. 25°C) 4,64
4,88
C-RN223H8A 80244088B
2200
FV68S ... 1350
4,97
A
luminum plate fin / Copper tube
0,61
2
2
11
WHT - PNK
Outdoor Unit AER522SH3
12
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Controller PCB
Type Rotary (Hermetic) Compressor model C–R221H5S 80687145B Nominal output W 2,200 Compressor oil ... Amount cc 4GSD–T or SAY-56T ... 1,350 Coil resistance (Ambient temp. 25°C) C – R : 0.78
C – S : 2.41
Type Internal protector External protector (OLR)
Safety
Overload relay OL–D24
devices Operating temp. Open °C Automatic opening 150 ± 5
Close °C Automatic reclosing 63 ± 10
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 57 A
Run capacitor µF 40.0
VAC 400 Crank case heater 240V 30W Type Propeller Number ... Dia. mm 1 ... ø 460 Fan motor model ... Number Smen 19TFB6064 ... 1 No. of poles ... rpm (230 V, High) 6 ... 840 Nominal output W 63
Coil resistance (Ambient temp. 20°C) WHT – BRN : 99.5 ± 7%
WHT – YEL : 252.0 ± 7%
WHT – PNK : 63.2 ± 7%
Safety
Type Thermal protector
devices Operating temp. Open °C 130 ± 5
Close Automatic reclosing
Run capacitor µF 5.0
VAC 440 Coil Aluminum plate fin / Copper tube Rows 2 Fin pitch mm 2.0 Face area m
2
0.610
External Finish Acrylic baked-on enamel finish
Heat
Exch. Coil
CompressorFan & Fan Motor
Outdoor Unit AE522SC
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No. Johnson Control
Type Rotary (Hermetic) Compressor model C-R223H8S - 806187188B Source 380 – 400 V – 3N
~
50 Hz Nominal output W 2200 Compressor oil ... Amount cc SUNISO 4GSD-T ... 1350 Coil resistance (Ambient temp. 25°C) Ω C – R : 4.97
C – S : 4.64 R – S : 4.88
Type Internal protector External protector
Safety
Overload relay - HOE-10TB TH-7A
devices
Operating temp.
Open °C 125 ± 5 — Close °C Automatic reclosing
Operating amp.(Ambient temp. 25°C) - 7A
Run capacitor
µF
VAC — Crank case heater 240V 30W Type Propeller Q´ty ... Dia. mm 1 ... ø460 Fan motor model ... Q´ty SMEN 19TFB6064 ... 1 Source 220 – 230 V
~
50 Hz No. of poles ... rpm (220 V, High) 6 ... 840 Nominal output W 50 Coil resistance (Ambient temp. 20°C) WHT – BRN : 99.5 / WHT - YEL : 252
WHT – PNK : 63.2
Safety
Type Internal type
devices
Operating temp.
Open °C 130 ± 5 Close Automatic reclosing
Run capacitor
µF 5.0
VAC 400 Coil Aluminum plate fin / Copper tube Rows 2 Fin pitch mm 2.0 Face area m
2
0.610
External Finish Acrylic baked-on enamel finish
Controller
PCB
Heat
Exch. Coil
Compressor
Fan & Fan Motor
13
Outdoor Unit AE522SC3
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No. Johnson Control
Type Rotary (Hermetic) Compressor model C-RN223H8A 80244088B Source 380 – 400 V – 3N
~
50 Hz Nominal output W 2200 Compressor oil ... Amount cc FV68S ... 1350 Coil resistance (Ambient temp. 25°C) Ω C – R : 4.97
C – S : 4.64 R – S : 4.88
Type Internal protector External protector
Safety
Overload relay HOE-10TB TH-7A —
devices
Operating temp.
Open °C Automatic opening — Close °C Automatic reclosing
Operating amp.(Ambient temp. 25°C) 7A —
Run capacitor
µF
VAC — Crank case heater 240V 30W Type Propeller Q´ty ... Dia. mm 1 ... ø460 Fan motor model ... Q´ty SMEN 1STFB6064 ... 1 Source 220 – 230 V
~
50 Hz No. of poles ... rpm (220 V, High) 6 ... 840 Nominal output W 50 Coil resistance (Ambient temp. 20°C) WHT – BRN : 99.5 / WHT - YEL : 252
WHT – PNK : 63.2
Safety
Type Internal type
devices
Operating temp.
Open °C 130 ± 5 Close Automatic reclosing
Run capacitor
µF 5.0
VAC 440 Coil Aluminum plate fin / Copper tube Rows 2 Fin pitch mm 2.0 Face area m
2
0.610
External Finish Acrylic baked-on enamel finish
Controller
PCB
Heat
Exch. Coil
Compressor
Fan & Fan Motor
14
Outdoor Unit AER522SCL3
Magnetic Contactor (MG) HE-20FT31B
Coil rating AC 220/240V, 50Hz Coil resistance (at 25°C) 1,050 ± 15% Contact rating (Main) AC 220-240V, 20A
Thermostat (Fan Speed Control 23S) YTB-S383
Switching temp. °C
high LOW 28.5°C ± 1 low HIGH 31°C ± 1
Outdoor Unit AE522SC
Thermostat (Fan Speed Control 23S) MQT5S-27YZJ
Switching temp. °C
high LOW 23.5°C
+0 –2.5
low HIGH 27.0°C
+0 –3
Contact rating AC 220V, 3A
Power Relay G7L-2A-TUB
Coil rating AC 200–240V, 50/60Hz Coil resistance k(at 23°C) ( 21 ± 15% ) Contact rating AC 220V, 25A
Outdoor Unit AE522SC
15
D
OTHER COMPONENT SPECIFICATIONS
Electro Magnetic Contactor (MG) HOE-10TB TH-7A
Magnetic Contactor
Coil rating AC 220–240V, 50Hz / AC 240–260V, 60Hz Coil resistance (at 25°C) 1,260 ± 10% Contact rating (Main) AC 440V, 8A
Thermal relay (Overcurrent relay)
Operating amperes 7A
Negative Phase Relay (47C) RDR-S400
Rating AC 415V, 3-phase 50Hz Contact rating AC 400V, 1A Operation Positive phase: ON
Negative phase: OFF
Thermostat (Fan Speed Control 23S)
YTB-S383
Switching temp. °C
high LOW 28.5°C ± 1 low HIGH31°C ±1
Outdoor Unit AE522SC3
16
Loading...