Euro Kitchen Appliances Installation Manual And User's Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
Installation Guide
and Users Manual
SPAGNA VETRO 168 Series
(Remote Control)
236536
IMPORTANT:
Read and save these instructions.
NOTICE:
Installer: Leave this guide with the homeowner
Homeowner: Keep this guide for future reference
Wall Mount Range Hood
Important Safety Notice
Read all Instructions before Installing and operating this appliance
The installation in this manual is intended for qualified installers, service technicians or persons with •
similar qualified background. Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction.
DO NOT• attempt to install this appliance yourself. Injury could result from installing the unit due to
lack of appropriate electrical and technical background.
Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any •
parts for installing, cleaning or servicing.
Activating any switch ON before completing installation may cause ignition or an explosion.•
Due to the size and weight of this range hood, two people installation is recommended.•
To reduce the risk of fire, electric shock, or injury to persons:
For general ventilating use only. • DO NOT use to exhaust hazardous or explosive materials and vapors.
The combustion air flow needed for safe operation of fuel-burning equipment may be affected by this •
unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society of
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre-•
vent power from being switched ON accidentally.
Clean grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make •
sure to vent air outside. DO NOT vent exhaust into spaces between walls, crawl spaces, ceiling, attics
or garages.
Ducted fans MUST always be vented to the outdoors.•
Use only metal ductwork and this unit MUST be grounded.•
Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent •
back drafting.
When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid-•
den utilities.
All electrical wiring must be properly installed, insulated and grounded.•
Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire.•
Check all joints on duct work to insure proper connection and all joints should be properly taped.•
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the •
vendor.
To reduce the risk of a stove top grease fire:
Keep all fan, baffle, spaces, filter, grease tunnel, oil container and grease-laden surfaces clean. Grease •
should not be allowed to accumulate on fan, baffle, spaces, filter, grease tunnel and oil container.
Always turn range hood ON when cooking at high heat or when cooking flaming foods. •
Use high settings on cooking range only when necessary.•
Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers •
that may ignite. Heat oils slowly on low or medium settings.
Page 1
Important Safety Notice
Read all Instructions before Installing and operating this appliance
Clean ventilating fan frequently.•
Always use appropriate cookware and utensils size.•
Always use cookware appropriate for the size of the surface element.•
To reduce the risk of injury to persons in the event of a stove top grease fire:
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn OFF the burner. •
BECAREFUL TO PREVENT BURNS. NEVER PICK UP A FLAMING PAN—you may be burned.
KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames DO
NOT go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT or 911.
DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result.•
Use an extinguisher ONLY if:•
You know you have a Class A, B, C extinguisher, and you already know how to operate it.•
The fire is small and contained in the area where it is started.•
The fire department is being called.•
You can fight the fire with your back to an exit.•
To reduce the risk of injury to persons in the event of a gas leaks:
Extinguish any open flame.•
DO NOT turn on the lights or any type of appliance.•
Open all doors and windows to disperse the gas. If you still smell gas, call the gas company and fire •
department, or 911 immediately.
Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can happen if the instructions are not followed.
WARNING
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others.
All safety messages will follow the safety alert symbol and the word “WARNING”.
Euro-Kitchen, Inc. declines all responsibility in the event of failure to observe the instructions given
here for installation, maintenance and suitable use of the product.
Euro-Kitchen, Inc. further declines all responsibility for injury due to negligence and the warranty
of the unit automatically expires due to improper maintenance.
Euro-Kitchen, Inc. will not be held responsible for any damages to personal property or real estate
or any bodily injuries whether caused directly or indirectly by the range hood.
4mm x 16mm Tapping Screw6 Pcs
4mm x 10mm Tapping Screw16 Pcs
Optional: Toggle Bolt with Tapping Screw for Air Diverter2 Set
Optional: Screw for Charcoal Filter3 Pcs
Aluminum Filter(s)
Air diverter
(Optional re-circulating kit)
Remote Control
Mounting Bracket
(Not supplied with re-circulating kit)
Charcoal Filter
(Optional re-circulating kit)
Page 4
Venting RequirementsHeight & Clearance
Vent system must terminate to the outside •
(roof or side wall).
DO NOT terminate the vent system in an at-•
tic or other enclosed area.
DO NOT use 4” (10.2 cm) laundry-type wall •
caps.
Use metal/aluminum vent only. Rigid metal/•
aluminum vent is recommended.
DO NOT use plastic vent.•
Always keep the duct clean to ensure proper •
airflow.
Calculate the following figures before instal-•
lation:
Distance from the floor to the ceiling.1.
Distance between the floor to the coun-2.
tertop/stove.
Distance between the countertop/stove 3.
to the range hood (recommend* 28” to
31”).
Height of hood and duct cover.4.
For the most efficient & quiet operation:
A distance of 28” to 31” is recommended* •
between stove top and the bottom of range
hood.
It is recommended that the range hood be •
vented vertically through the roof through 6”
(15.2 cm) or bigger round metal/aluminum
vent work.
The size of the vent should be uniform.•
Use no more than three 90° elbows.•
Make sure there is a minimum of 24” (61 •
cm) of straight vent between the elbows if
more than one elbow is used.
DO NOT install two elbows together.•
The length of vent system and number of •
elbows should be kept to a minimum to provide efficient performance.
The vent system must have a damper. If •
roof or wall cap has a damper, DO NOT
use damper (if supplied) on top of the range
hood.
Use silver tape or duct tape to seal all joints •
in the vent system.
Use caulking to seal exterior wall or roof •
opening around the cap.
* Due to different ceiling height configurations, rec-
ommended height may not be applicable.
Maximum* ceiling clearance
110” at 31” hood mounting
height above countertop/stove
(may vary with different
model). Chimney extensions
available for higher ceiling.
Min: 28”
Max: 31”
Max*: 110”
36” base
Mounting
Bracket
Standard
Upper
Chimney
Extension available*
Standard
Lower
Chimney
Extension available*
Range hood
Countertop/Stove
* Higher ceiling requires chim-
ney extension. Available at
http://www.euro-kitchen.com.
Page 5
IMPORTANT:
A minimum of 6” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased separately) •
must be used to maintain maximum airflow efficiency.
Flexible 6” round duct provided for convenience, always use rigid type metal/aluminum ducts if available to •
maximize airflow when connecting to provided duct.
Please use • Duct Run Calculation below to compute the total available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase •
duct size from 6” to 7” or 8”. If a reducer is used, install a long reducer instead of a pancake reducer. Reducing duct size will restrict airflow and decrease airflow, thus reduce duct size as far away from opening as possible.
If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.•
Minimum mount height between stove top to hood bottom should be no less than 28-inch*.•
Maximum mount height between stove top to hood bottom should be no higher than 31-inch*.•
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat •
damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance
and efficiency.
If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood •
mounting height above range.
* Due to different ceiling height configurations, recommended height may not be applicable.
Minimum Duct Size:
Round - 6” minimum•
Rectangular - 3-1/4 x 10” minimum (requires a 6” to 3-1/4x10” adaptor, not supplied)•
Calculating Vent System Length
To calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the system
from the recommended maximum duct run.
Duct Run Calculation:
Recommended maximum run
6” or 3-1/4 x 10” duct50 ft
Vent piece deduction
Each 90º elbow used9 ft
Each 45º elbow used5 ft
Each 6” to 3/14 x 10” transition used7 ft
Side wall cap with damper0 ft
Roof cap0 ft
Duct Run Calcuation example:
One roof cap, two 90º elbow, and one 45º elbow used:
0ft + 9ft + 9ft + 5ft = 23ft used.
Deduct 23ft from 50ft, 27ft maximum available for
straight duct run.
Page 6
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.