Euroheat Tavo Aqua IN1215 Installation & Servicing Instructions Manual

PART NUMBER
SERIAL NUMBER
Installation & Servicing Instructions
TAVO AQUA
Wood Burning Stove
IN1215 Edition 1 June 2010
Installation & Servicing Instructions
TAVO AQUA
IN1215 Ed1
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010
Instructions Part Number IN1215 Ed 1
2
Contents
1 Important information prior to installation and commissioning ......................... 2
2 Scope of delivery ....................................................................................... 2
2.1 Transport/unpacking/checking ....................................................
2
3 Planning data ............................................................................................ 2
3.1 Dimensional drawings ...............................................................
2
3.2 Specications ...........................................................................
2
3.3 Combustion air supply ...............................................................
2
3.4 Components of the TAVO AQUA ..................................................
2
3.5
Calculation of heat requirement ..................................................
2
4 Setting up the boiler .................................................................................. 2
4.1 Requirements of the assembly area .............................................
2
4.2 Minimum distances ...................................................................
2
5 Assembly of the boiler ................................................................................ 2
5.1 Removal of the rear panel ..........................................................
2
5.2 Changing the ue outlet ............................................................
2
6 Connection to the chimney .......................................................................... 2
7 Hydraulic connection .................................................................................. 2
7.1 Thermal discharge safety device .................................................
2
7.2 Return ow boost (absolutely necessary) .....................................
2
7.3 Water system, decrease in performance ......................................
2
7.4 Expansion tank.........................................................................
2
7.5 Hydraulic system ......................................................................
2
8 Overview of the most important points ......................................................... 2
9 Customer services and spare parts ............................................................... 2
10 Your specialist company ............................................................................. 2
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010
Instructions Part Number IN1215 Ed 1
3
Installation & Servicing Instructions
TAVO AQUA
IN1215 Ed1
IMPORTANT
The installation of this appliance must comply with all local regulations, including those referring to National and European Standards before it can be operated. The stove is not suitable for a shared flue. However, for England and Wales, only, the coming into force on 1st April 2002 of SI 2002 No 440 exempts the householder from this legal requirement for the installation of solid fuel fired appliance whose rated heat output is 50kW or less in a building having no more than 3 storeys (excluding any basement) if a Competent Engineer is employed who is registered under the Registration Scheme for Companies and Engineers involved in the Installation and Maintenance of Domestic Solid Fuel Fired Equipment operated by HETAS Ltd. These registered Competent Engineers may also carry out associated building work necessary to ensure that the installed appliance complies with Building Regulations without involving the Local Authority Building Control Department.
This appliance MUST be installed with a thermal store/buffer/accumulator. This is specialised work and may need specific skills.
Improper adjustment, alteration, maintenance or the fitting of replacement parts not recommended by the manufacturer can cause injury or property damage. Do not operate the stove with faulty seals or damaged glass.
Due to the high operating temperatures of this appliance it should be located away from pedestrian traffic and away from furniture and draperies. Do not store paper or wood near the appliance. Any mats and rugs put in front of the stove should be fire proof and secured to prevent the possibility of tripping.
Advise all persons as to the stove’s high surface temperatures. If it is possible for children or infirm adults to come into contact with the stove, fit a suitable fire guard.
It is imperative that all air passageways into, out of, and within the appliance are kept clean. All permanent ventilation into the room provided for the stove must remain clear and unobstructed at all times. Consideration must be given to the need for extra ventilation if another heating source needing air is to be operated simultaneously. If an extraction fan is proposed to be fitted to a connecting area of the house, after the stove has been installed, professional advice should be sought from a qualified engineer.
The user should be advised that the appliance should be inspected regularly and the chimney cleaned at least annually. More frequent cleaning may be required and the advice of a qualified chimney sweep should be sought.
Our range of stoves is capable of operating with outstanding efficiency if the flue system is correct. Because so little heat is wasted to the flue it is possible that moisture within the products of combustion will condense if the heat losses within the flue way are too great and allow the flue gases to cool. For this reason we recommend that the stove is fitted with a suitable flue liner, the same diameter as the flue spigot, to prevent the possibility of acidic damage to the fabric of the chimney and damage to the stove which will reduce the longevity of the stove.
When correctly installed, the stove is designed to produce heat, safely. It cannot do so if the installation is less than absolutely stable, constructed of materials suitable for such an installation and consideration has not been given to the possibility of people with less than ideal common sense operating it.
Have the existing chimney swept by a chimney sweep. Although you will be lining the chimney, any deposits left in the chimney will cause problems and may become a fire hazard.
Your attention is drawn to the precautions and responsibilities under the Health and Safety at Work Acts, and whatever new legislation being introduced during the life of this document.
Installation & Servicing Instructions
TAVO AQUA
IN1215 Ed1
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010
Instructions Part Number IN1215 Ed 1
4
IMPORTANT STANDARDS/DIRECTIVES
In addition to the local re and building regulations the following standards and directives must be observed when installing and commissioning the boiler:
ÖNORM M7550: Central heating boiler up to 100 °C: concepts, requirements, inspections,
designation of standards ÖNORM M 7510 / 1: Directives for the inspection of central heating systems. ÖNORM M 7510 / 2: Directives for the inspection of central heating systems; standards. ÖNORM B8130: Safety devices. ÖNORM B8131: Closed water-heating systems; safety-related requirements. ÖNORM B8133: Safety-related requirements for hot water generation systems.
DIN 4751 Part 1: Safety-related equipment of heating systems with ow temperatures of up to
110°C (120°C in preparation). DIN 4751 Part 2: Safety-related equipment of heating systems with ow temperatures of up to
110°C (120°C in preparation). Open and closed water heating systems up to
349 kW (300,000 kcal/h) with thermostatic fuse. DIN 4751 Part 4: Safety-related equipment of heat generation systems with ow temperatures
of up to 120°C; closed water heating system with static levels of more than 15
m or nominal heat capacities of more than 350 kW.
DIN 1988: Potable water conduit systems in properties (technical regulations).
ÖNORM EN 303-5: Heating boiler for solid fuels, manually and automatically fed up to 300 kW.
concepts, requirements, inspections, designation. ÖNORM M7135: Compressed wood and compressed bark in natural state - Pellets and
briquettes. ÖNORM M7136: Compressed wood in natural state - wood pellets – quality control of transport
and storage logistics. ÖNORM M7137: Compressed wood in natural state - wood pellets - Requirements for storage of
pellets at customers premises.
TRVB H118: Technical directive for preventive re protection for automatic biomass heating
systems.
Type test:
The TAVO AQUA was successfully tested by RWE Power AG according to EN 13240:2005. The stove complies with the requirements for emissions according to Art. 15a B-VG concerning safety precautions and the saving of energy.
The original type certicates are held by „SHT Heiztechnik aus Salzburg GmbH“.
Max. permitted operating pressure: 3.0 bar Test pressure:
6.0 bar Permitted ow temperature: 100°C
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010
Instructions Part Number IN1215 Ed 1
5
Installation & Servicing Instructions
TAVO AQUA
IN1215 Ed1
Part No: Part Description Part
Boiler
8B2520 8B2521 8B2522 8B2523 8B2524 8B2525
Boiler body TAVO steel jacket Boiler body TAVO steel jacket, front, black Boiler body TAVO soapstone Boiler body TAVO soapstone, front, black Boiler body TAVO Ananas Boiler body TAVO Ananas, front, black
1
Accessories
2X2510 2X4216 2X4303 3F2508 3F2510 5C9220 9M1433 9M2433
Heat-resistant glove, silver with RIKA Logo Brush 40/45 angular 529 lg Ash damper Thermostat with immersion sleeve for RLA Thermal discharge safety device Safety valve 3 Bar ¾” outlet Operating instructions Assembly instructions
1 1 1 1 1 1 1 1
Optional accessories
A53100
Reflux heating assembly comprising:
• Heating pump
• Expansion tank
• Thermal mixing valve
• Shut off cocks
• Pipework, complete
Transport/unpacking/checking
After unpacking the delivery carefully check for completeness and any transport damage. Note any visible deficiencies on the delivery note and report them to the manufacturer immediately.
Photographs of parts supplied
Installation & Servicing Instructions
TAVO AQUA
IN1215 Ed1
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. June 2010
Instructions Part Number IN1215 Ed 1
6
3 Planning data
Enclosed you will nd all the necessary data for the planning of the installation
3.1 Dimensional drawings
1243
586
528
100
1164
190
80
126
174
607.5
55
174 190
9090
8
7
5
6
4
3
2
1
157
341
384.5
419.7
490
341
201
217
132.5
60
17
Flue pipe optionally top or
at the rear
1 Connection of internal expansion tank* 2 Safety heat exchanger ON 1” AG 3 Safety heat exchanger OFF 1” AG 4 Flow connection 1” AG
5,6 Immersion sleeve ½” IG
7 Return port ¾” AG
8
Connection for external combustion air 125 mm
* Required only for internal reflux boost assembly and
closed off with a ½” cap.
Loading...
+ 14 hidden pages