Euroheat FB50, FB80 Gas Operating Instructions Manual

© Euroheat Distributors (H.B.S) Ltd. Nov 2004
1
E & EO Instructions Part Number IN1095 Edition C
Operating Instructions
Insert FB50 & FB80 Gas
Insert Conventional Flue
Serial Number
Euroheat Distributors
(H.B.S.) Ltd.,
Unit 2, Court Farm
Business Park, Bishops Frome, Worcestershire,
WR6 5AY.
© Euroheat Distributors (H.B.S) Ltd. Nov 2004
2
E & EO Instructions Part Number IN1095 Edition C
Do not operate the stove with its door open or if its glass is damaged.  Do not operate the stove if the ceramic log effect kit is damaged or are not as
Illustrated in the installation manual. Do not add additional coals or logs to those supplied with the stove.
No attempt should be made to adjust the appearance of the flame by adjusting the
burner or ceramic log effect kit without suitable gas analysis equipment. Any change in the appearance of the flame pattern should be reported to your installer.
Improper installation, adjustment, alteration, service, or maintenance can cause
injury or property damage.
This appliance should be installed and maintained by a suitably qualified heating
engineer
Ensure this and all other manuals remain with the appliance Do not store or use petrol or other flammable vapours and liquids in the vicinity of
this or any other heating appliance.
This appliance is designed to become hot and should be located away from
pedestrian traffic, furniture and draperies.
Advise all adults and especially children to be alert to the hazard of the stove's high
surface temperatures. Supervise young children and infirmed when they are in the same room as the appliance and fit a suitable fireguard.
It is imperative that all stove and room ventilation air passageways are kept clear. The appliance should be inspected annually by a qualified and CORGI registered
engineer.
The registration document must be completed by the installer and returned within
fourteen days to Euroheat Distributers (H.B.S.) Ltd.
IMPORTANT
READ BEFORE OPERATING THE
STOVE
Decoration Around the Insert
Inflamable materials should not be used with in 200mm of the Inserts surrond. This includes wall paper and other decorative inflamable coatings. For additioal advice see the Inserts installation instructions.
© Euroheat Distributors (H.B.S) Ltd. Nov 2004
3
E & EO Instructions Part Number IN1095 Edition C
Ignition Sequence
By turning the control dial to aline the "star" symbol with the index line, gas will be allowed into the pilot burner when the dial is depressed fully into the valve body. By simultaneously depressing the control dial and the spark generator button, the pilot burner will be ignited. The spark generator button can be released when the pilot flame is observed. (If the background noise of the room is low it will be possible to detect that the clicking sound produced by the spark will be softened when the gas ignites). The control dial must be held depressed for twenty seconds whilst the pilot flame heats the thermocouple. When the thermocouple heats, it produces a voltage which informs the valve that the pilot flame is established and the valve takes over the supervision of the pilot flame. The control knob can now be released and the pilot will remain alight.
Main Burner Control Thermostatic
When the gas valve has supervision of the pilot flame it will supply gas to the main burner and allow the main burner to light. The main burner can be ignited by turning the control dial anticlockwise to any position up to the position marked "6", the highest heat setting. The main burner will light automatically from the pilot burner and will burn at a high output until the temperature setting chosen on the control dial is reached, the valve will then turn off the burner or reduce its heat output to one third. The burner will relight or its output will increase to meet the thermostat demands.
Manual
If thermostatic control of the stove needs to be overridden the control dial should be turned anticlockwise to any position beyond the ignition "star" symbol. The manual control slid from its off position, indicated by the white dot at the left of the valve facia, and repositioned to give the desired flame size. The minimum and maximum positions correspond to the width of the white wedge printed above the slide. The manual control will be disabled if the control dial is turned to its ignition setting and the main burner will ignite and burn at the manual override setting immediately the control dial is turned anticlockwise from its ignition setting.
Turning Off The Stove
The stove may be turned to pilot flame only, by turning the control dial to its ignition position, or extinguished completely by turning the control knob completely clockwise to the "off" position indicated with a white "dot".
Note:- It will not be possible to ignite the stove if the thermocouple is hot. If the stove has inadvertently been extinguished or the control dial was released before the thermocouple was heated sufficiently to allow the valve to supervise the pilot burner, turn the control knob to the "off" position and wait for
Eurosit (630) Thermostatic Gas Valve Controls
6
4
2
Ignition Button
Index line
Pushing the button
energizes the
electronic spark
generator to produce
a pulsed sparks to
ignite the pilot flame.
Thermostatic control
Allows the stove to be controlled by the
room temperature, maintaining a
constant ambient temperature.
Manual control
Disables the thermostatic
control of the stove and
allows the stove to operate
at any chosen setting.