CONTENT
1 .............................................. Notice
2 .............................................. Installation Requirements
3 .............................................. Installation – Fitting the Rangehood.
4 .............................................. Safety Warning
5 .............................................. Instructions for Use
6 .............................................. Maintenance
7 .............................................. Troubleshooting
2
(1) Notice
1. Thank you for choosing our Rangehood. Please read this
instruction manual carefully before use.
2. The installation work must be undertaken by a qualified and
competent installer in compliance with applicable Australian
Standards.
3. Euro Appliances disclaims all liability for any damage or
injury caused as a result of not following these instructions for
installation.
This Rangehood is suitable for connection to a 240V, 50Hz
power supply with a proper earth.
Contents
1 x Rangehood
1 x Packet of Screws & Fittings
1 x plastic outlet with flaps
1 x Set of Chimney Pieces (Upper & Lower)
1 x Operating & Installation Instructions
3
(2) Installation - Requirements
Warning: This Rangehood is suitable for indoor installation only in
accordance with the following:
Installation must be performed by a qualified competent installer.
If installed above a cooking appliance, the minimum distance from
the cooking surface is 65cm,and the maximum distance is 75cm.
.
150mm diameter of duct needs to be used for ventilation.
1. Before installation, please ensure the area is clean to avoid
suction of any debris such as bits of broken wood, sawdust,
etc.
2. Flexible duct bending should be ≥120°.
3. There shall be adequate ventilation of the room when the
Rangehood is used at the same time as appliances burning gas
or other fuels (not applicable to appliances that only discharge
the air back into the room).
4. The air must not be discharged into a flue that is used for
exhausting fumes from appliances burning gas or other fuels
(not applicable to appliances that only discharge the air back
into the room).
5. Regulations concerning the discharge of air have to be
fulfilled.