Introduction A1-4 Using Euro-M ERiDIAN with Code or Tag B1-5 Intelligent Setting B6-7 When Problems Arise C1-3 Setting Individual Area D1-3 Chime Facility E1 Omitting Zones E2-3 Keypad Personal Attack E4 Manager Menu F1-2 Omitting 24 hr Zones F3 Changing Date & Time F4 Change/Add Codes or Tags F5-10 Review Histo ry Log F11-12 SMS Phonebook F13 Walk Testing Detectors F14 Testing your Soun der F15 SMS Messaging System F16-17 Dial Out Menu F18 Allow Engineer Menu F19 Block Remote Set F20 Perform Anti-Code Reset F21 Service & Codeholder Records G1-2
Note the specification of Euro-MERiDIAN may vary between models, and some facilities in the manual may not be available. Check with your installer for full details. This equipment may be used in systems installed to a lower grade, which will be agreed with your installation company.
© Castle Care-Tech 2006 (RINS1020) Issue 1
Page A2
You’ve Made the Right Choice
Using your Euro-MERiDIAN Alarm System just couldn’t be easier!
This is the Keypad from where you control your Alarm System*.
Note:
For your security, the keypad becomes disabled for 90 seconds after 24 incorrect key­presses, or after 6 attempts to present invalid tags. It will subsequently be disabled again after 7 further incorrect key-presses or after another invalid tag is presented. Once a correct code or tag has been registered, the keypad is returned to normal operation.
*Please note that Keypad design may differ from that shown.
The MERiDIAN Keypad
The display gives you any important messages. It will alert you if you need to call your alarm installation engineer.
The 10 digit numeric keypad is where you use your PIN code.
The A B C D keys help simplify use, and will illuminate to highlight your choice of security cover, or flash if there is a problem.
This is where you present your
Tag
.
MERiDIAN
TIME
:
MAINS FAIL
Page A4
Warning Indications
All setting points (Keypads or Tag Readers) have lamps to clearly indicate what is happening.
The ‘Alert’ lamp will flash if there is information available to you. Enter your code to see the information. After a code has been entered, one of the following lamps will light: Alarm, tamper or fault. The relevant detail of the problem will be shown on the display. To clear the display, press the ‘Yes’ key (or the display will clear automatically after 3 minutes.)
The ‘Alarm’ lamp will flash after code entry if an alarm occurs.
The ‘Tamper’ lamp will flash after code entry if the wiring or equipment is tampered with.
The ‘Fault’ lamp will light after code entry to indicate if a technical fault occurs.
The ‘Unset’ lamp will light for 5 seconds if the panel is completely Unset (steady) or if some areas remain Set (flashing). It will also light during the setting procedure, going off once set.
Alert Alarm Tamper Fault Unset
Using Tags
Euro-MERiDIAN’s High Security Proximity Tag (or Card) will set or unset your Alarm system with the minimum of fuss or complexity.
The Tag contains NO batteries and is completely maintenance free.
Just touch the Tag to the fascia below the logo to use.
The Keypad will BEEP to acknowledge the TAG.
Using the Keypad with your PIN Code or
Page B1
Security Checks
Before you set your system:
You must ensure all doors and windows are securely closed and any pets or people are excluded from areas protected by movement sensors.
Close Windows
Close Doors
Exclude Pets & People
Page B2
Leaving the Building
If you are leaving the building, go to Keypad and key in your PIN code, or present your Tag.
Exit tone Starts
The appropriate area (ABCD) keys will illuminate.
(If flexi-set is enabled you will be able to choose which areas you set, see page D2)
Leave by agreed Exit Route
Close and Lock the Final Exit Door
Finally, press the ‘Push to Set’ button (if fitted) that is mounted externally by the final exit door.
Exit tone will cease
Euro-MERiDIAN is now SET
SETTING [009] OFFICE
Exit Timer
If your exit is timed, you will see the above screen.
If you use a Push-to-Set button, or final-door­set, you will see the screen below.
MERiDIAN
TIME
:
L
eave via
Exit Route
Page B3
Faults when you Switch On
If when you key in your PIN code (or present your Tag) a warning tone sounds and the
fault
lamp comes on, the keypad display will show the nature of the problem.
An appropriate
A B C D
key will flash to indicate within which area the fault exists.
The tone will cease after about 10 seconds.
Press the NO key
The system will remain unset, so you can resolve the problem.
For example, you may have left a door open, if so, close the door.
Now commence the setting procedure again.
UNABLE TO SET
BACK DOOR
Page B4
Faults when Leaving the Building
If when you have closed the final exit door (and pushed the
‘Push
to Set’
button
if fitted
), the exit tone continues to sound an interrupted tone…
“beep – beep – beep – “
You have probably left a protected door on the exi t route open.
Return to the keypad and note the message on the display.
Stop the setting procedure with your PIN code, or Tag.
Close the open door
Now commence the setting procedure again (see B2).
EXIT VIA
HALLWAY
Page B5
Entering the Building
To enter the building you
must
use the agreed entry route and go straight to the keypad.
Entry tone will be sounding
“beep – beep – beep –“
Key in your PIN code, or present your Tag.
Entry tone will cease
To indicate that the system has unset, the unset lamp will illuminate for five seconds.
Euro-MERiDIAN is now UNSET
ENTRY [010]
TIME
**
ENTRY
[
020]
TIME
Page B6
Part-Setting the System
Intelligent Set
(if programmed)
If you wish to set
Euro
-MERiDIAN and stay in the building (eg set the alarm at night), the Euro­MERiDIAN’s intelligent operating system will realise which level of security you require and will set only part of the system.
You will NOT need to press a Push-to-Set button if you set only part of a system.
If intelligent set is not installed on your system, you may part set the system as described on Pages D1-D2.
Page B7
Staying in the Building
Intelligent Set
To Part Set
Euro
-MERiDIAN go to the keypad and enter your PIN code or present your Tag.
The appropriate
A B C D
keys will
illuminate
Exit tone will start
Leave the protected area and retire to the un-protected area (eg upstairs).
Euro-MERiDIAN will detect you have gone upstairs and set the appropriate areas accordingly.
After a preset time the exit to ne will cease.
Euro-MERiDIAN is now Part Set
When Problems Arise, Just Key in your PIN Code or
Page C1
Silencing Alarms
If an Alarm tone sounds, the Alert lamp will flash:
Just key in your PIN code or Present your Tag.
The Alarm will stop sounding
The display will indicate the problem.
Press the
‘YES’
Key
Euro-MERiDIAN will advise you on any action that is needed. If the ‘Alert’ LED indication remains lit, there is additional information available. Enter your PIN or present your Tag to view.
Call Engineer Low Volts
Alarm Silenced Low Volts
Page C2
Engineer Reset
When an alarm has been cancelled and the Police have been notified by the Alarm Receiving Centre, you will see the following screen when you try to use the system.
It is usually necessary for an engineer from your installation company to check the installation and reset the system for further use.
But if you have
caused the alarm in error
your Alarm Receiving Centre or Alarm Installation Company may permit you to reset the system without an engineer present.
You will be required to quote a 6-digit code by telephone (advise them that the system is a Castle Euro-MERiDIAN). You will then be given a special code which will reset the system
for that
one occasion
only.
Press ‘NO’
Enter the anti-code given to you by your installation company.
You alarm in now restored and ready to use.
This 6-digit code is also displayed in th e ‘user menu’ – see page F21.
Quote G19867
Anti-Code Needed
E
uro
-
MERiDIAN
TIME:
Engi
neer Restore
Performed
Quote G19867
Anti-Code Needed
Ent
er your Code
[* ]
Page C3
Automatic Inhibit
Euro-MERiDIAN is designed to automatically disable certain functionality. The factory default settings are as shown below:
Intruder Alarm Signal
After 3* unconfirmed alarms in the same area or 1 confirmed alarm.
Tamper Alarm Signal
After 3* unconfirmed alarms in the same area or 1 confirmed alarm.
Keypad
After 23 keypresses without entering a valid code, keys are disabled for 90 seconds. After reinstatement, this will be repeated after each 7 keypresses until a valid code is entered.
Tag Reader
(or Tag at a keypad)
After 6 presentations of an invalid tag, the reader will be disabled for 90 seconds. After reinstatement, this will be repeated for each invalid tag until a valid tag is used.
*
This figure is programmable by the