EURAMCO SAFETY’S INLINE HEATER Model HA02 / HA03 User and Safety Guide
SPECIFICATIONS
Model: HA02 Power: 110VAC, 50/60Hz, 360watts, IP20 Heat Energy: 13.5 kW / 46k Btu max (gross) Dimensions: 560L x 330H x 355D (mm) Weight: 13.5kg
For use in: The United Kingdom
OPERATING INSTRUCTIONS
1. Insert UB20 blower into the Heater air inlet and plug the UB20 into the “Switched Power” receptacle. Ensure the UB20 blower’s “ON” / “OFF” switch, located on the side of the UB20 is in the “ON” position.
2. Connect the Euramco Safety supplied regulator / hose assembly between the propane tank and the Heater gas inlet.
3. Attach the UB20 Duct Canister or flexible duct to the Heater air outlet ring and fully extend.
4. Plug the HA01 or HA02 Heater into a 110VAC power source, or the HA03 into a 230VAC power source.
5. Install Optional Thermostat: If the temperature of the space to be heated needs to be regulated install the optional thermostat and set to highest temperature. Note: The heater does not require the use of a thermostat to support Heater operation.
6. Open valve on propane tank.
7. Toggle the Heater switch to the “ON” position.
8. After the Heater lights up, adjust the Thermostat Temperature Setting for the desired room temperature. The red light on the Heater switch will cycle “ON” and “OFF” with the burner flame to regulate the room temperature.
9. Set the Heater control panel fan switch to the “ON” position if you want the UB20 blower to run continuously during both thermostat “ON” and “OFF” cycles and after the heater switch has been turned off.
10. Set the Heater control panel fan switch to the “AUTO” position if you want the blower to cycle “ON” and “OFF” with the demand for heat. When the Heater switch is turned “OFF” the fan will also turn off after the heater has cooled down.
11. If the ignition of the flame fails or the red switch light on the control panel fails to light the cause is most likely due to a loss of airflow, propane tank is empty, or the internal over temperature switch tripped. Examine system and remove blockage, or fill tank as necessary. Wait for the Heater to purge for 30 to 90 seconds and attempt to re-ignite the flame. If the Heater fails to re-ignite itself, toggle the heater switch to the “OFF” position. Unplug the heater from its power source. Recheck all gas and electrical connection and proceed with step 4 above.
TURN-OFF PROCEDURES
1. SHUT OFF PROPANE AT TANK.
2. When Red switch light goes off, press switches to OFF and AUTO.
3. DO NOT UNPLUG PO WER until the heater ON/OFF switch is OFF and heater has completed cool down cycle.
SAFETY FEATURE
Euramco Safety’s Inline Heater is equipped with a safety switch to shut down propane in-flow when flame is lost. Heater will shut down, purge for 30-90 seconds depending on type of failure and proceed through 3 trials to re-ignite
and restart. After 3 failures to re-ignite and restart, heater will go into lock-out mode and will not re-start. In case of
lock-out, operator must unplug the heater from its power source to re-boot the circuit and then proceed with normal start up procedures.
GENERAL MAINTENANCE
Do not disassemble Inline Heater for maintenance reasons.
Clean inlet and outlet periodically to remove accumulated dust or particles.
Clean with cloth, not pressure washer, using commercially available biodegradable cleaning solutions.
Model: HA03 Power: 230VAC, 50/60Hz, 360watts, IP20 Heat Energy: 13.5 kW / 46k Btu max (gross) Dimensions: 560L x 330H x 355D (mm) Weight: 13.5kg
For use in: Belgium, France, Germany, Ireland,
Netherlands, Portugal, Spain, Sweden
Do not use solvents containing chlorinated hydrocarbons (i.e., MEK, Acetone).
Tighten all loose fasteners immediately. Check all at least once per year.
Do not over tighten fasteners.
There are no user serviceable parts.
Contact Euramco Safety for replacement part
applicability.
WARNINGS
NOT FOR USE WITH LIQUID PROPANE. FIRE COULD RESULT.
PROPANE GAS (I
) ONLY (37mBar)
3P
HOT SURFACES! KEEP EXHAUST AREA CLEAR!
May automatically start/stop if equipped with thermostat, or if over heating or air blockage
Keep Propane Cylinder Away From Heater.
Water certification IP22
Not for home or recreational vehicle use.
The hose and regulator should be protected from traffic, building materials and contact with hot surfaces both during use and
while in storage.
Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electrical shock.
Fire, burn, inhalation, and explosion hazard.
Keep solid combustibles such as building materials, paper, or cardboard a safe distance away from the heater as recommended
by the instructions.
Never use the heater in spaces which do or may contain volatile or airborne combustibles, or products such as gasoline, solvent, paint thinner, dust particles or unknown chemicals.
CERTIFICATION
Gastec Certification B.V. declares that the Portable Construction Heaters, types HA02 and HA03, made by Euramco Safety, Inc. in Spring Valley, CA, U.S.A., meet the Essential Requirements as described in the Directive on appliances burning gaseous fuels (90/396/EEC). Appliance type B
, Gas category I3p
23
WARRANTY
GENERAL WARRANTY
Euramco Safety warrants the Inline Heater against defects in material and workmanship for a period of 12 months from the date of original purchase. Authorization for warranty repairs must be obtained from the factory. There are no other warranties expressed or implied.
WARRANTY AND SERVICE
1) There are two types of services available for Euramco Safety products:
a. Warranty Service: Service is available in accordance with the warranty of the product line. The warranty is valid from the time the unit was put into service by the end-user but in no case longer than 24 months from the time the unit was shipped from Euramco Safety stock. All warranties by Euramco Safety are for defects in workmanship and materials and the liability is limited to repair of these defects and or replacement of the item. **For verification purposes the serial number of the unit and proof of purchase will be required. b. Non-Warranty Service: Service is available from our factory or authorized service center. Rates for service, spare parts pricing, etc. can be obtained directly from Euramco Safety or Hobrand BV.
2) Validation of Warranty : Validation consists of a simple check of our serialized records to insure validity of the warranty. The
customer can find the serial number affixed to the unit on a serialized sticker. Additionally dealer or distributor records can be consulted to determine date of sale. In most cases the serial number is sufficient unless a considerable amount of time has passed since the item left Euramco Safety stocks.
3) Authorization to Return for Service: Once the item has been successfully validated as under warranty, a return for service
authorization will be issued to the customer. Please insert a copy of this document into the return shipment in order to expedite repairs.
4) Freight Policy: Freight to return goods for service will be paid for by the company making the return.
5) Repairs and Determination of Warranty: After receipt of goods in which an authorization to return for service has been issued,
the goods will be evaluated to insure the required repairs are actually warrantable. a. If so, the goods will be repaired and dispatched back to the customer as expeditiously as possible. Credit for incoming freight will be made only to authorized dealers as a credit on account and shall be an amount equal to the current rate to ship via UPS Ground from the customer to the repairing facility. b. If not, an estimate will be made and forwarded to the customer for his review and approval. Upon approval the goods will be repaired and sent back to the customer.
6) Place of Repair: Repair and Warranty services in Europe can be obtained at our authorized service center in the Netherlands.
Industrieweg 24
Hobrand BV
4153 BW Beesd Netherlands Tel: +31 (0) 344-663344
EURAMCO Safety Inc. 2746 Via Orange Way, Spring Valley, CA 91977 Tel. 800 472-6326 Fax 619 670-7345 Email: sales@euramcosafety.com
Web:: www.euramcosafety.com
PN: PI-0003 Rev. B 9/09