Euramco Safety EFi150xx User Manual

SM-EFATEX EV A
Portable Ventilators for Hazardous Locations Rated:
The Portable Ventilators described here in are intended for use in
rating. It is the user’s responsibility to determine the suitability of
equipment for the intended purpose.
II 2 G Ex d e IIB T6
TECHNICAL INFORMATION & INSTALLATION INSTRUCTIONS
Applicable Models:
UB20xx EFi120xx EFi75xx EFi85xx EFi150xx
UB20xx
EFi120xx EFi150xx
EFi75xx EFi85xx
SM-EFATEX Rev C
WARNING!
These units are intended for Explosive Atmospheres use in accordance with ATEX Directive 94/9/EC. It is the user’s responsibility to determine the suitability of this equipment for the intended purpose
CAUTION! THESE FANS ARE NOT INTENDED FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP.
Explosion Proof Fan Rated: Ex d e IIB T6
Euramco Safety hereby declares that the equipment listed in this manual conforms to the relevant Essential Health and Safety Requirements of the European Machinery Directive and standards listed below.
Council of European Communities Directives:
89/392/EEC as amended by 91/368/EEC and 93/44/EEC. Also EC Directives 93/68/EECI, 94/9/EC, and 76/117/EEC.
Standards to which conformity is declared:
See Declaration of Conformity (last page).
Category, Group and Zone Classifications
* According to ATEX Directive (94/9/EC)
T6 Temperature Classification
* According to EN 60079-0:2006 85°C T6
To ensure that there is no risk of ignition due to hot surfaces, the equipment is classified with regard to the maximum surface temperature of any part of the equipment while in operation based on the ambient temperature of 40°C. Equipment must be selected with a suitable temperature classification for the gases and vapors present where the equipment is to be installed. Ensure that the maximum surface temperature of any parts of the equipment are below the ignition temperature of the explosive atmosphere concerned. This equipment is intended for use in ambient temperatures ranging between -20°C and +40°C.
Classification: Ex de
* According to EN 60079-1:2004 Flame Proof Enclosures with Increased Safety Components.
Description of Apparatus The Portable Ventilator assemblies represented herein consist of an Approved Explosion Proof Electric Motor Rated: Ex d IIB by Bluffton Motor Works (Formerly Franklin Electric) as listed below and are covered by Certificate No. DEMKO 03 ATEX134885U.
EURAMCO SAFETY VENTILATOR
BLUFFTON MOTOR
MODEL #
INPUT VOLTAGE
EURAMCO PART #
BLUFFTON PART #
IMPELLER
UB20xx
115VAC, 60Hz
EF7002XX
1933007415
PLASTIC
UB20xx
230VAC, 50/60Hz
EF8002XX
1933007419
PLASTIC
EFi75xx
115/230VAC, 50/60Hz
EB7201XX EB7201XX-230
1133007405
METAL
EFi85xx
115/230VAC, 50Hz
EB8201XX EB8201XX-110
1223007401
METAL
EFi120xx
115/230VAC, 50Hz
EA8120XX EA8120XX-110
1223007401
METAL
EFi150xx 115/230VAC, 50/60Hz
EG8200XX EG8200XX-230
1133007417
METAL
The Flame Proof Electric Motor
Power Requirements: See chart above. Ambient Temperature Range: -20°C<T
amb
< +40°C
Ingress Protection to IEC 529: IP55
Marked: (“Bluffton Motor Works”) Electric Motor for Hazardous Locations Flame Proof Enclosure: Ex d IIB
The electric motor consists of one flameproof enclosure, which contains less than 6% magnesium by weight. The on/off switch is housed within the motor enclosure, and is operated by a shaft, extending out from the rear end bell to a lever. The lever is accessible via an attached push rod.
Motor connections are made through a non-detachable cable, secured to the motor with an approved Flame Proof cable gland from the company Hawke, Model 501/421/0/M20 and complies with International Standards EN 60079-0:2006, EN 60079-1:2004, EN 60079-7:2007.
The electric motor drives an aluminum or plastic fan blade containing less than 6% Magnesium by weight which is enclosed in a plastic, statically conductive housing with a conductivity rating of <1 giga­ohmes. Connection to the motor is facilitated by a Terminal Block mounted in an Increased Safety/Flame Proof Enclosure rated II 2 G Ex e II T6, from the company Rose Industries, Part No. 05080806, and covered under the certificate No. PTB 00ATEX1063. This box was designed to conform to International Standards EN 60079-0:2006, EN 60079-1:2004, EN 60079-7:2006, EN 61241-0:2004 and EN 61241­1:2004. The enclosure features stainless steel grounding lugs, with a high heat silicon gasket.
The Flame Proof enclosure has attached, approved, explosion proof cable glands Rated: IIGD Ex e II
Type: Polyamide Ex metric conforms to International Standards EN 60079-0:2006, EN 60079-7:2006, EN 61241-0:2006 and EN 61241­1:2004.
Material: Polyamide Color: Black/Blue Grommet: NBR Protection classification: IP68 Temperature range: -4°F to +212°F Approval: PTB 00 ATEX 1063
The power cable from each blower is terminated with either a yellow 120VAC or a Blue 240VAC Explosion-proof plug to match the operating voltage of the motor. The plugs are made by Appleton and complies with International Standards: EN 60079-0:2006, EN 60079-1:2004, EN 61241-0:2004, EN 61241-1:2004 & EN 60079-7:2006.
The fans are assembled with both Inlet and Outlet Safety Guards that conform to the safety standards to prevent danger zones being reached by upper limbs in the BS EN 294:1992 Guards Standard.
II 2 G Ex d e IIB T6 CE 0539 Demko 09 ATEX 0926969
TECHNICAL INFORMATION & INSTALLATION INSTRUCTIONS
SM-EFATEX Rev C
Loading...
+ 3 hidden pages