2) Product data / Product range
T echnical data – inverter series E800
Rated voltage 3-Phase 380…460V - 3 Ph. 220...240V - 1Ph. 220...240V - Tol. +/- 15%
Input frequency 44….67 Hz
Power supply
EMC filter Integrated for 2. Environment – C3 (up to 90 kW)
Output voltage 0……...U-input
Output frequency 0……...650 Hz
Resolution of output frequency 0,01 Hz
Output
Overload capability 120% - 60 sec. / 10 Min
PWM control-modes
V/Hz - Mode
Permanentmagnet Synchronmotor control (Software option)
PWM frequency 0,8…10 kHz
V/Hz characteristic Linear, quadratic, and user-programmable curve
Torque boost Automatic / Manual
Motor data input Manual input / intelligent AUTOTUNING function
DC-Brake Freq. threshold, duration and intensity programmable
Control mode
Brake chopper Integrated chopper transistor (Brake resistors – see product table)
Display
7 Segment LED display -4- digit For programming and visualization of different operating parameters
Inverter control - Start/Stop To configure: terminals / operation panel / serial link
Digital control inputs 8 (5) digital inputs (HIGH/LOW configurable), pulse input
Speed reference signal
Potentiometer (on operating panel / Extern), analogue input (terminals) ,
operating panel keys, pulse input, serial link
Reference analogue channels
2 Analogue channels 12 BIT 0…10V, 0..(4)20 mA (with programmable offset,
gain – to concatenate mathematically each other)
Analogue outputs
2 (1) analogue output channels, both programmable in gain, different
functions to assign (0…10V, 0..20 mA)
Digitale outputs 2 (1) digital outputs (different functions to assign)
Relays output 1 switchover contact 5 A 230 V (programmable for different functions)
Interface Serial link (MODBUS – ASCI/RTU)
Jog mode, 12V / 50 mA auxiliary power supply on terminals
PI-control
I/O Channels,
control functions
Special function - control options
Fixed frequency control "Catch on the fly function", AUTORESET/RESTART
functions
Overvoltage, Undervoltage
Overcurrent, Overload, Motor-Overload, Output-short
Electrical protection functions
Phaseloss, Motor-Phase imbalance
Protection
functions, incl.
fault memory
Thermal protection functions
Heatsink overtemperature – Motor overtemperature (PTC/KLIXON),
Motor I
2
xt
Operating panel Remote keypad / programming tool
Brake resistors High power resistors for heavy duty operation
Filter / chokes PFC chokes – dv/dt limiting output filter - sinusfilter
Optionals
PC-Link Software (via MODBUS) Special tool for programming, control and diagnostic (parameter set memory)
Protection IP20 – IP21 (optional)
Operating temperature -10……+50 °C
Humidity Max. 90 % not condensing, no corrosion
Elavation 1000 m - 1% derating / 100m above
Environmental
conditions
Vibration Max. 0,5 g
0,2……400 kW
Power range
EMC EN61800-3(2004)
Standards
Safety EN61800-5-1 2003
E800 – Rev.01 -EN- SOFT Rev. 2.04
© 2015 EURADRIVES EUROPE GmbH
- 13 -