Euphonix SC263 Installation Manual

SC263
System Computer
Installation Manual
Document Revision: A
Part Number: 840-11305-01
Euphonix is Avid. Learn more at www.avid.com
Regulatory and Safety Notices
FCC Notice
Part 15 of the Federal Communication Commission Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference free radio frequency spectrum. Many electronic devices produce RF energy incidental to their intended purpose.
These rules place electronic equipment into two classes, A and B, depending on the intended use.
Class A devices are those that may be expected to be installed in a business or commercial environment. Class B devices are those that may be expected to be installed in a home or residential environment. The FCC requires devices in both classes to be labeled with the interference likelihood and additional operating instructions. The rating label on the equipment will show which class the product is (A or B). Class A product will not have an FCC logo. Class B equipment will have an FCC logo. The information statements differ on the two classes.
Class A Equipment
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.
Euphonix is Avid. Learn more at www.avid.com
Modifications
The FCC requires the user to be notified that any changes or modifications made to Avid hardware that are not expressly approved by Avid Technology may void the user’s authority to operate the equipment.
Cables
Connections to Avid hardware must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
PRODUCTS WITH MULTIPLE POWER I NP UTS :
WARNING: Each power input is intended to be connected to a separate branch circuit. Risk of high leakage exists if multiple inputs are connected to a single source and protective earth is not present. A QUALIFIED SERVICE PERSON shall verify that each socket-outlet from which the equipment is to be powered provides a connection to the building protective earth. If any do not provide this connection, the QUALIFIED SERVICE PERSON shall arrange for the installation of a PROTECTIVE EARTHING CONDUCTOR from the separate protective earthing terminal to the protective earth wire in the building.
Canadian ICES-003
Class A Equipment
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecté toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Euphonix is Avid. Learn more at www.avid.com
European Union Declaration of Conformity
Declaration of conformity Konformitätserklärung Déclaration de conformité Declaración de Confomidad Verklaring de overeenstemmin g Dichiarazione di conformità
We/Wir/ Nous/WIJ/Noi:
Avid Technology
1925 Andover Street Tewksbury, MA, 01876 USA European Contact: Nearest Avid Sales and Service Office or
Avid Technology International B.V. Sandyford Industrial Estate Unit 38, Carmanhall Road Dublin 18, Ireland
declare under our sole responsibility that the product, erklären, in alleniniger Verantwortung,daß dieses Produkt, déclarons sous notre seule responsabilité que le produit, declaramos, bajo nuestra sola responsabilidad, que el producto, verklaren onder onze verantwoordelijkheid, dat het product, dichiariamo sotto nostra unica responsabilità, che il prodotto,
Euphonix is Avid. Learn more at www.avid.com
Product Name(s) : System Computer Model Number(s): SC263 Product Options: This declaration covers all options for the above product(s).
to which this declaration relates is in conformity with the following standard(s) or other normative documents. auf das sich diese Erklärung bezieht, mit der/den folgenden Norm(en) oder Richtlinie(n) übereinstimmt. auquel se réfère cette déclaration est conforme à la (aux) norme(s) ou au(x) document(s) normatif(s). al que se refiere esta declaración es conforme a la(s) norma(s) u otro(s) documento(s) normativo(s). waarnaar deze verklaring verwijst, aan de volende norm(en) of richtlijn(en) beantwoordt. a cui si riferisce questa dichiarazione è conforme alla/e seguente/i norma/o documento/i normativo/i.
The requirements of the European Council: Safety: Directive 2006/95/EC EN 60065:2002 /A1:20 06 EMC: Directive 2004/108/EC EN 55103-1:1996 EN 55103-2:1996
Euphonix is Avid. Learn more at www.avid.com
LED Safety Notices
Avid hardware might contain LED or Laser devices for communication use. These devices are compliant with the requirements for Class 1 LED and Laser Products and are safe in the intended use. In normal operation the output of these laser devices does not exceed the exposure limit of the eye and cannot cause harm.
Standard to which conformity is declared: (IEC 60825-1)
Optical connections are located on the rear panel and are typically labeled “Optical” or “SPDIF/ADAT.” The exact location of optical connections is identified more clearly elsewhere in the documentation for the Avid hardware device.
Euphonix is Avid. Learn more at www.avid.com
Disposal of Waste Equipment by Users in the European Union
Rack-mount Requirements
The following rack-mount requirements are listed below:
• Elevated Operating Ambient — If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment might be greater than room ambient. Therefore, consider installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
• Reduced Air Flow — Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Do not block vents.
• Mechanical Loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
• Circuit Overloading — Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
• Reliable earthing — Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (for example, use of power strips).
Euphonix is Avid. Learn more at www.avid.com
Lithium Battery R eplacement
If a battery is supplied in this Avid product it must only be replaced by qualified personnel. Contact Avid Customer Support for assistance.
WARNING
Danger of explosion if battery is incorrectly replaced. Replace with only the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
ADVARSEL!
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
ADVARSEL!
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt
fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.
Euphonix is Avid. Learn more at www.avid.com
Overview
The SC263 is the System Control Computer for broadcast versions of the S5 and MaxAir families
4U, chassis inc. machine control, GPIO (TT002), and Mic and Monitoring communication control
Redundant PSU’s and SNMP System monitoring
Front Panel
Power Switch and Status Indicators: See Status Module below.
Software Status Indicator: The blue “wave” in the Euphonix logo lights up to indicate
the software in the SC263 is operating correctly.
Status Module
Power Switch: Turns the unit on or off.
System Reset Switch: Forces a manual reset of the SC263.
Alarm Cancel Switch: Cancels the audible hardware fault alarm.
LED Status Indicators: Indicates the status of the power supply, cooling fans,
temperature, and file system activity. Healthy status is indicated with a green light,
faults are indicated with a red light.
USB Ports: Connect a USB storage device to update software
Euphonix is Avid. Learn more at www.avid.com
Connections
Rear Panel
1. VGA Connector (DA-15): Main video monitor connection.
2. Keyboard (PS/2): Main keyboard connection.
3. Mouse (PS/2): Main trackball connection.
4. Serial Port 1 (DE-9): Com1; currently not used. (Com2 is wired internally to the SNMP
board’s Com port.)
5. Serial Port 2 (DE-9, top) and Serial Port 3 (DE-9, bottom): Com3 and Com4,
respectively; currently not used
6. TT002 (75-ohm BNC, DE-9 female, DE-9 male): BNC port is for Bi/Tri-Level Video
input; DE-9 female is for RS422 (Sony 9-pin); DE-9 male is for Midi Machine Control
and Time Code I/O (via breakout cable).
7. GPIO Port 1 (DC-37): GP Inputs and Outputs 1 to 16.
8. GPIO Port 2 (DC-37): GP Inputs and Outputs 17 to 32.
9. LAN Port 1 (Onboard RJ45): Connect to EuCon Network Switch via RJ45 (provided).
10. LAN Port 2 (Auxilary RJ45): Optional connection for external network.
11. SNMP LAN Port (RJ45): Connect this port to a network with SNMP monitoring or e-
mail services to enable the hardware monitoring system to report errors.
12. USB Ports: Connect the USB MIDI Interface to one of these ports. Connect a USB
memory device to one of these ports for file backup, application installations or updates.
13. Power Connectors (IEC): Accepts two standard IEC power cords (provided). Two auto
ranging switching supplies accept voltages between 100–240 VAC, 50–60 Hz.
14. TCC Main Port (DC-62): Connect TCC breakout cable (provided) to this port. This
cable breaks out to four DA-15 connectors that provide control hookup for the MC524
Monitor Interface and three ML530 Mic/Line Interfaces.
15. TCC Extension Port (DC-62, optional): Connect a second TCC breakout cable to this
port connect up to four a to dditional ML530 Mic/Line Interfaces.
16. SNMP Serial Port (DE-9): This port is used to configure the SNMP card via another
computer.
Euphonix is Avid. Learn more at www.avid.com
Connect the machine room KVM extender (transmitter end) to the VGA, keyboard, and
SC263 Technical Specification
Power Requirements
mouse connectors to the rear panel of the SC263. A second KVM extender (receiver end) should be installed at the control surface, close to where the Emix monitor, keyboard and mouse are to be locat ed. MaxAir systems have the rec eiver end inside the CM404. The KVM extenders are connected by a single CAT5 cable built into the console ethernet harness (provided).
More information
Please check the website www.euphonix.com for the Service manual and Operational Manual
Specifications
100-240 VAC; 50 or 60 Hz (Auto-ranging)
Power Consumption 8-4 A Per Input
Tempreture of Operation 5-35 ºC
Dimensions H 177mm W 482mm L 482mm Weight 20kg Heat Dissipation 685BTU/hr
Euphonix is Avid. Learn more at www.avid.com