Etymotic Research Music-Pro mp9-15 User Manual

Page 1
User Manual
English
Page 2
2
Warnings
Failure to follow these recommendations may severely reduce the amount of hearing protection provided by the earplugs.
• Earplugs comply with EN-352 standard of measurement.
• Eartips t ear canal diameters of 6-13 mm. See Eartip section for details.
• Earplugs must be tted, adjusted and maintained
to the manufacturer’s instructions to achieve the expected attenuation and hearing protection.
• Use earplugs at all times in noisy surroundings.
• Make certain that the earplugs provide adequate
protection for the noisy environment.
• Earplugs are reusable. Regularly inspect the earplugs
to assure their continued serviceability.
• Connecting cord should not be used where there is a risk that the connecting cord can be caught up
during use.
Page 3
Warnings (continued)
3
• This product may be adversely affected by certain
chemical substances. Further information should be sought from the manufacturer.
• This earplug is provided with level-dependent
attenuation. The wearer should check correct
operation before use. If distortion or failure is detected, the wearer should refer to the manufacturer’s advice for maintenance and replacement of the battery.
Warning: The output of the level-dependent
circuit of the hearing protector may exceed the daily limit sound level.
• To determine if the device is working, insert a
battery, cup the device in your hand and listen for acoustic feedback (squeal). If feedback is present, the battery is working.
Page 4
Eartips
4
Flexible Neck Cord
Filter Tool and Extra ACCU•Filters
Protective Case
Removal Cord
Eartip
Battery Door
2-Position
Switch
Cleaning Tool
ACCU•Fit
Eartips
For Large Yellow Foam (10-14 mm) go to: www.etymotic.com
312 Batteries
LRG Gray
3-ange
8-13 mm
Black
Foam
8-13 mm
Glider
8-11 mm
SM Frost
3-ange
7-11 mm
SML–Long Stem
Frost 3-ange
7-11 mm
LRG–Long Stem
White 3-ange
8-13 mm
SM Beige
Foam
6-9 mm
Identication
Page 5
Eartips (continued)
Battery Insertion
5
Selecting an eartip:
The eartip that is most comfortable is the likely choice, but it must seal well for maximum protection.
When changing eartips, push the neck cord against the body of the device; then secure the eartip completely on the stem.
The battery must be installed correctly or the device will not work. The battery door will not close if the battery is
upside down.
• Remove the tab on the battery before
inserting it in the device.
• Open the battery door and insert
the battery with the at side facing up.
• Be sure the + on the battery is on the
same side as the + on the door.
Correct orientation of battery
correct incorrect
Page 6
Insertion & Removal
6
Insertion
• Make sure the eartip is clean.
• Pull the ear up and out while inserting (Fig. 1).
• Twist and push gently until the
eartip seals in the ear canal.
(Fig. 2).
• When using 3-ange eartips,
moistening may ease insertion.
• When using foam eartips: Roll
down or compress foam before inserting. Hold the eartip in place for about 5 seconds while foam expands to create a tight seal in the ear canal
(Fig. 3).
• When using glider eartips
no compression is needed; simply push into ear.
Removal
• Remove with a slow
twisting
motion for all eartips.
• After removal, place earplugs
in a clean, protective case.
Fig. 1
Fig. 2
Fig. 3
Page 7
Operation
7
ON/OFF
Earplugs turn on and off by opening and closing the
battery door. Note: It is not necessary to remove the battery as long as the door is open wide enough to disable the circuit.
Two Modes of Protection
Natural Hearing with 15-dB Sound Reduction
(switch toward battery door)
• Natural hearing until sound exceeds safe levels
• Automatic 15-dB protection when hearing is at risk
• Impact noise protection
Enhanced Hearing with 9-dB Sound Reduction
(switch away from battery door)
• 6-dB gain for soft sounds
• Automatic 9-dB protection when hearing is at risk
• Impact noise protection
Battery Door
Open = OFF Closed = ON
2-Position Switch
Toward battery door = 15-dB mode Away from battery door = 9-dB mode
Page 8
Battery Life
Low Battery Warning
8
Warning: Performance may deteriorate with battery
usage. The typical period of continuous use that can be expected from the earplug battery is 300 hours.
Battery life is estimated at 2-3 weeks for continuous operation. Each device uses one #312 zinc-air battery. It is not necessary to recycle these batteries. Zinc-air
batteries are not harmful to the environment and can be discarded in the trash. Keep batteries out of the reach of children.
Recommendation: Carry spare batteries in case a battery reaches end of life while using a device.
LOBAT
: A ticking sound becomes faster and louder, like the sound of a motorboat when the battery is about to die. After the warning sound rst becomes audible, it may be a few hours before the battery
dies. Performance and protection do not change
while LOBAT
is sounding.
Page 9
Changing Filters
9
Earplugs have special lters that enhance sound quality and prevent ear wax from entering the devices. A lter should be changed if the volume decreases or sound quality declines.
ACCU•Filter™ Removal
Note: Use the tool to remove the filter.
ACCU•Filter™ Replacement
Note: Do not use the tool to replace the filter.
1. Remove eartip.
1. Insert a new filter.
2. Insert tool into the filter.
2. Press gently against a hard surface to secure the filter in place.
3. Remove the filter.
3. Re-attach the eartip.
Page 10
Troubleshooting
Warranty
10
Problem: No sound. What to do:
• Check to see if the battery door is closed (device turned on).
• Check battery; replace if dead.
• Clean the eartip and the end of the device.
• Check the lter
- remove the lter
- listen for sound to return before replacing the lter
• If sound returns, replace the lter. Once the lter is removed, discard it and do not reuse.
Etymotic will repair or replace defective product
at its option if returned within one year of purchase
to our designated service facility. This warranty is in lieu of all other warranties, expressed or implied, including, but not limited to, any implied warranty of merchantability or tness for a particular purpose.
Page 11
Maintenance
Storage
11
Simple cleaning with the tool provided will keep the eartips clean and the devices working properly.
• Clean after each use. Wipe clean with a damp cloth.
• Do not immerse earplugs in water.
• Do not clean with harsh chemicals. Alcohol is not
recommended.
• Use the cleaning tool to pick out or brush off debris.
• 3-ange eartips can be removed and cleaned
in mild detergent. Dry eartips thoroughly.
• Replace 3-ange eartips every 60-90 days.
• Replace foam and glider eartips frequently, as needed.
• Remove the devices before using hair products.
• Do not expose to extreme heat or moisture.
• Avoid dropping or hitting on a hard surface.
• Use only accessories and spare parts from Etymotic Research, Inc. to ensure continued performance to specication.
• Always store earplugs in a clean, protective case.
• Do not store other objects, except a neck cord, in the
earplug case.
Page 12
Noise Reduction Rating
DECIBELS
25
(WHEN USED AS DIRECTED)
THE RANGE OF NOISE REDUCTION RATINGS
FOR EXISTING HEARING PROTECTORS
IS APPROXIMATELY 0 TO 30
(HIGHER NUMBERS DENOTE GREATER EFFECTIVENESS)
ETYMOTIC RESEARCH, INC. ELK GROVE VILLAGE, IL 60007
LABEL REQUIRED BY U.S. E.P.A. REGULATION 40 CFR Part 211, Subpart B.
Federal law prohibits removal of this label prior to purchase.
MP-9-15
EPA
Passive Attenuation
Frequency (Hz) 125 250 500 1000 2000 4000 8000 Mean Attenuation (dB) 25.3 24.0 24.3 25.6 29.6 32.5 34.8 Standard Deviation (dB) 5.9 4.6 5.6 4.8 3.3 3.8 4.0 APV (dB) 19.4 19.5 18.8 20.9 26.3 28.7 30.8
H = 26 dB M = 21 dB L = 20 dB SNR = 25 dB
Active Attenuation – Criterion Levels
Switch position H-noise M-noise L-noise (-15) 104 96 86 (-9) 99 93 85
H: Average attenuation characteristics in the high frequency spectrum (> 2 kHz) M: Average attenuation characteristics in the mid frequency spectrum (0.5-2 kHz) L: Average attenuation characteristics in the low frequency spectrum (< 0.5 kHz)
SNR (Single Number Rating): Average attenuation characteristics in the standard frequency spectrum The European Union testing was conducted by:
Central Institute for Labour Protection—National Research Institute (CIOP-PIB) ul Czerniakowska 16, 00-701 Warsaw, Poland. Notified Body No. 1437.
This product is in compliance with EN 352-2:2002 and EN 352-7:2002.
ETYMOTIC RESEARCH INC.
61 Martin Lane • Elk Grove Village, IL 60007 www.etymotic.com • 1-888-389-6684 • 847-228-0006
©2012. Music•PRO, Musicians Earplugs, ACCU•Technology, ACCU•F i t , ACCU•Filter and LOBAT are trademarks of Etymotic Research, Inc. ER098538-A
Loading...