GUARANTEE - The ThermaQ Blue
carries a two-year instrument guarantee
against defects in either components
or workmanship. During this period,
products that prove to be defective will,
at the discretion of ETI, be either repaired
or replaced without charge. The product
guarantee does not cover damage caused
by fair wear and tear, abnormal storage
conditions, incorrect use, accidental
misuse, abuse, neglect, misapplication
or modication. Full details of liability are
available with ETI's Terms & Conditions of Sale
at etiltd.com/terms. In line with our policy
of continuous development, we reserve the
right to amend our product specication
without prior notice.
The Bluetooth® word mark and logos
are registered trademarks owned by the
Bluetooth SIG, Inc. and any use of such
marks by ETI is under license.
Google Play and the Google Play logo are
trademarks of Google Inc.
Apple, the Apple logo, iPhone, and iPod
touch are trademarks of Apple Inc.,
registered in the U.S. and other countries.
App Store is a service mark of Apple Inc.,
registered in the U.S. and other countries.
iOS is a trademark or registered trademark
of Cisco in the U.S. and other countries and
is used under license.
Android is a trademark of Google Inc.
THERMAQ® BLUE
With Bluetooth® LE
Wireless Technology
Electronic Temperature Instruments Ltd
Manufactured by
Worthing · West Sussex · BN14 8HQ
01903 202151 · sales@etiltd.com · etiltd.com
545-901/19.11.18
Operating Instructions
INSTRUMENT OPERATION - Connect the
probe(s) via the miniature thermocouple
socket(s) located on the end of the
instrument. Apply the tip of the probe to
the substance, medium or surface to be
measured. The instrument reading may
take several seconds to stabilise, depending
on the nature of the measurement and
sensitivity of the probe.
BUTTON FUNCTIONS
Transfer/On-Off button
ON - Press to turn the instrument on.
OFF - Hold down for 3 seconds to
switch off.
MEASURE/TRANSFER - Press to
measure and transfer result via
Bluetooth (if connected).
CLEAR BONDING - See Bonding
Backlight button
Press to toggle the backlight on and
off. Note the backlight will switch off
automatically after ten seconds.
ALARMS - The default setting is off. The
high/low alarms can be switched on/off
and adjusted through the ThermaQ App.
The current alarm status is indicated by the
instruments display and status LED.
SENSORS - Only use type K (Nickel
Chromium/Nickel Aluminium) thermocouple
probes (to BS EN 60584-1:2013) tted with
suitable miniature type K thermocouple plugs.
TEMPERATURE MEASUREMENTS - The
instrument measures its inputs at a set
measurement interval and displays the value
in ºC or ºF. If Sensor 2 is switched on, the
display will alternate between the two sensor
readings every 5 seconds with 'Sen 1' & 'Sen 2'
indicating which sensor reading is currently
being displayed.
CONNECTION - Use a Bluetooth® Low Energy
'Smart or Smart Ready' iOS or AndroidTM
host device with the ThermaQ App installed
to make connections to the instrument.
The ThermaQ app can be downloaded free
from the App Store (Apple devices) or on
Google PlayTM (Android devices). For full
device compatibility visit etiltd.com. Open
the ThermaQ App and connect to the device
via the Devices screen, use the instrument’s
serial number to select the correct device
from the list. Once connected the ThermaQ
App will begin receiving and storing
measurement data.
Please note: When not connected the
instrument continues to measure using its
current settings but no readings are stored in
the instrument.
SETTINGS - Adjustable via the ThermaQ
App include: °C or °F, Measurement Interval,
Auto-off Interval, Sensor Name(s) and High/
Low Alarm levels. Sensor 2 can be set on/
off. All settings are stored in the instrument
and are downloaded to the ThermaQ App on
connection.
AUTO-OFF - If the instrument is not
connected to Bluetooth within the set Autooff interval, it will shut down. This function
can be switched off via the ThermaQ App.
ALARM STATUS LED - A red ash indicates
a temperature is in an alarm condition and
a green ash indicates the temperatures are
within the set alarm levels. The LED ashes
every measurement whether connected via
Bluetooth or not.
OPEN CIRCUIT/FAULTY PROBE - If the probe
has developed an 'open circuit' fault or is not
present the instrument will display 'Err'.
BONDING - This instrument does not need
to be paired/bonded to your host device.
Pairing/Bonding may cause connection
issues within Apps. If you encounter
connection problems please clear bonding as
described below.
Clear Bonding - start with the instrument
switched off, press and hold down the
Transfer button for approximately 5 seconds
until the display shows 'clr bond'.
BATTERY STATUS - This is indicated by the
ThermaQ App and the instrument’s display
using the battery symbol. When the battery
level falls below a safe level the instrument
displays 'Flat bat' before shutting down.
BATTERY REPLACEMENT - Unscrew the 4
screws located on the back of the instrument
and remove rear case. This can be difcult
especially after a long period but if done
gradually at each corner the case will come
apart. Replace the AA battery noting polarity.
Ret rear case and ret screws taking care
not trap/pinch the seal. Tighten the screws
evenly but do not overtighten as this will
affect the instrument water resistance.
WARNING: IPA and other solvents may
cause damage to the case and screen of this
instrument.