![](/html/af/af7b/af7b6e283f140a79038f0fb5c21fac0a502d3815650e240c812eef76d0e5354b/bg1.png)
AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL
PACKING LIST
QTY. PART NO. DESCRIPTION
1 23736 PD Pro
1 23731 Accessory Kit
1 24455 PD Pro Installation Sheet (this document)
1 23735 PD Pro Instruction Manual
The Snow Switch Model PD Pro Automatic Snow and Ice Melting System is permanently connected equipment
and does not have an internal disconnect device. A readily accessible disconnect device, short circuit, and current
NOTE:
protection shall be provided and are not supplied by ETI When power is applied, the system will start.
MODEL PD PRO
To Heater Cable
Heater Load Line / Yellow
Heater Load Neutral / Yellow
Heater Ground (shield)/Green
Power Cable
(provided by customer)
Sensor Wiring #18 AWG jacketed,
Heater Cable
(provided by customer)
Remote Wiring #22 AWG jacketed,
Temperature Sensor
Assembly Wiring
Size for 30 Amp
maximum load
3-conductor
Size to system load
2-conductor
#22 AWG jacketed,
2-conductor
South Bend, Indiana USA | networketi.com
SNOW/ICE CONTROL INSTALLATION GUIDE | PART NO. 24455 REV D
![](/html/af/af7b/af7b6e283f140a79038f0fb5c21fac0a502d3815650e240c812eef76d0e5354b/bg2.png)
Cable Function Wire Lead Connect To:
INPUT POWER (provided by customer) Line 1
OUTPUT TO HEATER
(provided by customer)
South Bend, Indiana USA | networketi.com
Line 2 / Neutral Ground
Heater Load Line
Heater Load Neutral
Heater ground (Shield)
2
SNOW/ICE CONTROL INSTALLATION GUIDE | PART NO. 24455 REV D
Black
White
Green
Yellow
Yellow
Green