Ethos IS100 Installation Instructions Manual

Page 1 of 2
Specifications / Installation instructions
Freestanding Models: Genesis, Aquos, Phoenix
( E ffective 1 Jan 2017 )
IMPORTANT
It is the responsibility of the installer to ensure that the installation of this appliance complies with AS/NZS 2918:2001
Page 1 of 6 Specications / Installation Instructions Insert model: Zero Clearance Cabinet for Ares Fire Eective 1st January 2017
Retain these instructions for future reference
Installation instructions for the Ethos IS100 wood re with EZC-031135 Zero Clearance Cabinet and EXA-10042 EconAir ue system
These instructions should be read in conjunction with the instruction and install documents for the IS100 wood re.
Page 2 of 6 Specications / Installation Instructions Insert model: Zero Clearance Cabinet for Ares Fire Eective 1st January 2017
Following these instructions allows for the Ethos IS100 Insert wood re to be safely installed in a timber frame wall, without the need for further heat protection beyond what is provided as part of the EZC-031135 Zero Clearance Cabinet and the EXA-10042 EconAir ue system.
Warning: It is critical that these instructions are followed fully and that no substitute parts are used.
Important Installation Notes
• Combustible materials must be kept to a minimum of 25mm away from all parts of the Zero Clearance Cabinet and the 250mm diameter outer ue liner.
• Adequate ventilation must be available for cooling the Zero Clearance Cabinet. Refer installation diagram example for supplied ventilation plate mounting details on page 6.
• If installing on combustible oor surfaces such as timber, option base panel part model EZC-031140 is required to be tted beneath the Zero Clearance Cabinet. Further details are shown on page 4.
ETPD0122 rev.7
Following these instructions allows for the Ethos IS100 wood fire to be safely installed in a timber frame wall, without the need for further heat protection past that supplied as part of the Zero Clearance Cabinet and the Econ-Air flue system (see notes regarding installation on combustible surfaces).
WARNING: It is critical that these instructions are followed fully and that no substitute parts are used.
Econ-Air ue system parts list:
3 130mm x 1200mm S/S ue 1 130mm x 600mm S/S ue 2 200mm x 1200mm galv. liner 1 200mm x 600mm galv. liner 1 200mm x 1200mm galv. liner with ‘Z’ brackets 1 250mm x 600mm galv. liner 3 250mm x 1200mm galv. liner 1 130mm spider bracket 4 40mm x 40mm x 600mm mounting rails 1 Ethos revolving cowl (EXS-12010) 1 Ethos IS cowl base (EXS-12002)
These instructions should be read in conjunction with the
instruction documents supplied with your Ethos IS100
wood fire
Loading...
+ 4 hidden pages