EtherWan Hardened Media Converter Users Manual

Hardened Media Converter
This quick start guide describes how to install and use the hardened media converter. This is the media converter of choice for harsh environments constrained by space.
Physical Description

The Terminal Block and Power inputs

y DC Terminal Block Power Inputs: There are two pairs of power inputs can be used to power up this d evice. You need to have t wo power
DC JACK Power input: 12VDC.

The 10/100Base-TX and 100Base-FX Connectors

The 10/100Base-TX Connections
The following lists the pinouts of 10/100Base-T/TX ports.
The 100Base-FX Connections
The fiber port pinouts The Tx (transmit) port of device I is connected to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II.
Pin Regular Ports Uplink port
1 Output Transmit Data + Input Receive Data + 2 Output Transmit Data - Input Receive Data ­3 Input Receive Data + Output Transmit Data + 4 NC NC 5 NC NC 6 Input Receive Data - Output Transmit Data ­7 NC NC 8 NC NC
V7 1

The Port Status LEDs

Hardened Media Converter
LEDs State Indication FAULT
PWR1 PWR2
Steady Power redundant system or ports
function abnormally
Off Power redundant system and ports
function normally
Steady Power on
PWR stands for POWER Off Power off Steady Connection at the speed of 100Mbps100 (Mbps) Off Connection at the speed of 10Mbps Steady LFPT function enabled LFP Off LFPT function disabled
LNK/ACT
FDX/COL
Steady Valid network connection established
LNK stands for LINK
Flashing Transmitting or receiving data
ACT stands for ACTIVITY
Off Neither valid network connection
established nor transmitting/receiving data
Steady Connection in full duplex mode
FDX stands for FULL-DUPLEX
Flashing Collision occurred
COL stands for COLLISION
Off Connection in half-duplex mode

Functional Description

Meets NEMA TS1/TS2 Environmental requirements: temperature, shock, and vibration for traffic control equipment.
Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity for industrial environment.
Support 802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, full/half-duplex; Auto MDI/MDIX.
100Base-FX: Multi mode SC or ST type; Single mode SC or ST type; WDM Single mode SC type.
One DIP switch for configuring link-fault-pass-through, fixed speed, full/half duplex, and link down alarm.
Alarms for power and port link failure by relay output. Relay contact rating with current 1.5A @ 24VDC, 0.5
Operating voltage and Max. current consumption: 0.36A @ 12VDC, 0.18A @ 24VDC, 0.09A @ 48VDC. Power consumption: 4.32W Max.
Power Supply: Redundant DC Terminal Block power inputs or 12VDC DC JACK with 100-240VAC external power supply.
Field Wiring Terminal: Use Copper Conductors Only, 60/75 , 12-24 AWG torque value 7 lb-in.
-40 to 75 (℃℃-40 to 167) operating temperature range. Tested for functional operation @ -40 to 85 (℃℃-40 to 185). UL1604
Industrial Control Equipment certified Maximum Surrounding Air Temperature @ 74 (165℉).
Supports Din-rail, Panel, or Rack Mounting installation.
UL1604 Class I, Division 2 Classified for use in hazardous locations (applicable to versions with terminal block power option).
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D OR non-hazardous locations only.  WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has been removed or the area is known to be
non-hazardous.
WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability for Class I, Division 2.
A @ 120VAC.

Assembly, Startup, and Dismantling

Assembly: Place the media converter on the DIN rail from above using the slot. Push the front of the media converter toward the mounting surface until it audibly snaps into place.
Startup: Connect the supply voltage to start up the media converter via the terminal block (or DC JACK).
Dismantling: Pull out the lower edge and then remove the media converter from the DIN rail.
V7 2