EtherWAN EX47026-10B Quick Start Manual

Page 1
Hardened Ethernet Switch
Quick Start Guide
This quick start guide describes how to install and use the Hardened Ethernet Switch. This is the switch of choice for harsh environments constrained by space.
Physical Description
Power Input Assignment Power3 12VDC DC Jack
12-48VDC
Power2
Power Ground
12-48VDC
Power1
Power Ground
Earth Ground
Terminal Block
Relay Alarm Assignment
FAULT
*Relay warning signal disable for following:
The relay contact closes if Power1 and Power2 are both failed but Power3 on.
The relay contact closes if Power3 is failed but Power1 and Power2 are both on.
1
Page 2
Hardened Ethernet Switch
DC Terminal Block Power Inputs: There are two pairs of power inputs can be used to power up this switch. Redundant power supplies function is supported.
The 10/100Base-TX and 100Base-FX/BX Connectors
1. The 10/100Base-TX Connections
The following lists the pinouts of 10/100Base-TX ports.
Pin Regular Ports Uplink port
1 Output Transmit Data + Input Receive Data + 2 Output Transmit Data - Input Receive Data ­3 Input Receive Data + Output Transmit Data + 4 NC NC 5 NC NC 6 Input Receive Data - Output Transmit Data ­7 NC NC 8 NC NC
2. The 100Base-FX Connections The fiber port pinouts: The Tx (transmit) port of device I is connected to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II.
3. The WDM 100Base-BX Connections The fiber port pinouts: Only one single-mode optical fiber is
2
Page 3
Hardened Ethernet Switch
required to transmit and receive data.
The Port Status LEDs
3
Page 4
Hardened Ethernet Switch
LED State Indication
Power
Steady
Switch is properly connected to power and turned on.
Power 1 Power 2 Power 3
Off
Switch is not connected to power and is turned off.
Fault
Steady
Power redundant system failure occurred.
Port failure occurred (when link monitor alarm
dip switch is enabled).
Fault
Off
Power redundant system failure is not occurred.
Port failure is not occurred (when link monitor alarm dip switch is enabled).
Link monitor alarm dip switch is disabled.
10/100Base-TX, 100Base-FX/BX
Steady A valid network connection established.
LINK/ACT
Flashing
Transmitting or receiving data. ACT stands for ACTIVITY.
Steady Light solidly for a port transferring at 100Mbps.
100
Off
The port is transferring at 10Mbps If this LED is dark.
4
Page 5
Hardened Ethernet Switch
5
Functional Description
Complies with IEC61850-3 and IEEE1613 environmental requirements for power substation automation systems.
Complies with EN50121-4 environmental requirements for railway applications.
Meets NEMA TS1 & TS2 environmental requirements for traffic control equipments.
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial environment.
Supports IEEE802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, Full/Half-duplex, Auto-Negotiation, Auto MDI/MDIX.
100Base-FX: Multi/Single mode SC or ST type, 100Base-BX: WDM Single mode SC type.
Supports 2048 MAC addresses. Provides 448K bits buffer memory.
DIP switch configuration for link monitor alarm.
Alarms for power and port link failure by relay output 1A
@ 24VDC.
Power Supplies: Redundant 12-48VDC Terminal Block power inputs and 12VDC DC JACK with 100-240VAC external power supply.
Operating voltage and Max. current consumption: 0.5A @ 12VDC, 0.25A @ 24VDC, 0.125A @ 48VDC. Power consumption: 6W Max.
-40℃ to 75 (-40℉ to 167) operating temperature range. Tested for functional operation @ -40 to 85
(-40 to 185).
Supports DIN-Rail or Panel Mounting installation.
Page 6
Hardened Ethernet Switch
Assembly, Startup, and Dismantling
Assembly: Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place.
Startup: Connect the supply voltage to start up the switch via the terminal block (or DC JACK).
Dismantling: Pull out the lower edge and then remove the switch from the DIN rail.
6
Page 7
Hardened Ethernet Switch
7
Preface
A member of the growing family of rugged switches, this switch addresses a need for a smaller switch. This switch provides an affordable solution for rugged and outdoor environment, transportation road-side cabinet, industrial floor shop, multitenant dwellings or Fiber To The Home (FTTH) applications. Capable of operating at temperature
extremes of -40°C to +75°C, this is the switch of choice for harsh environments constrained by space.
Plug-and-Play Solution: The switch is a plug-and-play Fast Ethernet Switch in compact size. It doesn't have any complicated software to set up.
This manual describes how to install and use the hardened Ethernet Switch. This switch integrates full wire speed switching technology. This switch brings the answer to complicated hardened networking environments.
To get the most out of this manual, you should have an understanding of Ethernet networking concepts.
In this manual, you will find:
y Features on the switch y Illustrative LED functions y Installation instructions y Specifications
Page 8
Hardened Ethernet Switch
8
Table of Contents
QUICK START GUIDE 1
PHYSICAL DESCRIPTION 1
The Terminal Block and Power inputs 1 The 10/100Base-TX and 100Base-FX/BX Connectors 2 The Port Status LEDs 3
FUNCTIONAL DESCRIPTION 5 ASSEMBLY, STARTUP, AND DISMANTLING 6
P
REFACE 7
T
ABLE OF CONTENTS 8
P
RODUCT OVERVIEW 9
HARDENED ETHERNET SWITCH 9 PACKAGE CONTENTS 9 PRODUCT HIGHLIGHTS 10
Basic Features 10
FRONT PANEL DISPLAY 11 PHYSICAL PORTS 12
INSTALLATION 13
SELECTING A SITE FOR THE SWITCH 13 DIN RAIL MOUNTING 14 CONNECTING TO POWER 15
Redundant DC Terminal Block Power Inputs 15 12VDC DC Jack 15 Alarms for Power Failure 16
CONNECTING TO YOUR NETWORK 17
Cable Type & Length 17 Cabling 18
SPECIFICATIONS 19
A
PPENDIX A CONNECTOR PINOUTS 21
Page 9
Hardened Ethernet Switch
Product Overview
Hardened Ethernet Switch
Package Contents
When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller.
3 This Switch
3
User’s Manual
3 External power adapter & Power Cord
(Optional)
9
Page 10
Hardened Ethernet Switch
10
Product Highlights
Basic Features
Complies with IEC61850-3 and IEEE1613
environmental requirements for power substation automation systems.
Complies with EN50121-4 environmental requirements
for railway applications.
Meets NEMA TS1 & TS2 environmental requirements for traffic control equipments.
Meets EN61000-6-2 & EN61000-6-4 EMC Generic
Standard Immunity for industrial environment.
Supports IEEE802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, Full/Half-duplex, Auto-Negotiation, Auto MDI/MDIX.
100Base-FX: Multi/Single mode SC or ST type,
100Base-BX: WDM Single mode SC type.
Supports 2048 MAC addresses. Provides 448K bits
buffer memory.
DIP switch configuration for link monitor alarm.
Alarms for power and port link failure by relay output 1A @ 24VDC.
Power Supplies: Redundant 12-48VDC Terminal Block
power inputs and 12VDC DC JACK with 100-240VAC external power supply.
Operating voltage and Max. current consumption: 0.5A
@ 12VDC, 0.25A @ 24VDC, 0.125A @ 48VDC. Power consumption: 6W Max.
-40 to 75 (℃℃-40 to 167) operating temperature range. Tested for functional operation @ -40 to 85 ℃℃
(-40 to 185).
Supports DIN-Rail or Panel Mounting installation.
Page 11
Hardened Ethernet Switch
Front Panel Display
Status LEDs
11
Page 12
Hardened Ethernet Switch
LED State Indication
Power
Steady
Switch is properly connected to power and turned on.
Power 1 Power 2 Power 3
Off
Switch is not connected to power and is turned off.
Fault
Steady
Power redundant system failure occurred.
Port failure occurred (when link monitor alarm
dip switch is enabled).
Fault
Off
Power redundant system failure is not occurred.
Port failure is not occurred (when link monitor alarm dip switch is enabled).
Link monitor alarm dip switch is disabled.
10/100Base-TX, 100Base-FX/BX
Steady A valid network connection established.
LINK/ACT
Flashing
Transmitting or receiving data. ACT stands for ACTIVITY.
Steady Light solidly for a port transferring at 100Mbps.
100
Off
The port is transferring at 10Mbps If this LED is dark.
Physical Ports
This switch provides:
Eight 10/100Base-TX ports
Six 10/100Base-TX ports + one or two 100Base-FX/BX
ports
Four 10/100Base-TX ports + one or two 100Base-FX/BX ports
CONNECTIVITY
RJ-45 connectors
SC or ST connector on 100Base-FX fiber port.
SC connector on 100Base-BX fiber port.
12
Page 13
Hardened Ethernet Switch
13
Installation
This chapter gives step-by-step instructions about how to install the switch:
Selecting a Site for the Switch
As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
- The ambient temperature should be between -40 to 75
degrees Celsius.
- The relative humidity should be less than 95 percent,
non-condensing.
- Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards.
- Make sure that the switch receives adequate ventilation.
Do not block the ventilation holes on each side of the switch
- The power outlet should be within 1.8 meters of the
switch.
Page 14
Hardened Ethernet Switch
DIN Rail Mounting
Fix the DIN rail attachment plate to the back panel of the switch.
Installation: Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place.
Removal: Pull out the lower edge and then remove the switch from the DIN rail.
14
Page 15
Hardened Ethernet Switch
15
Connecting to Power
Redundant DC Terminal Block Power Inputs and 12VDC DC Jack:
Redundant DC Terminal Block Power Inputs
There are two pairs of power inputs can be used to power up this device. You only need to have one power input connected to run the switch.
Step 1: Connect the DC power cord to the plug-able terminal block on the
switch, and then plug it into a standard DC outlet.
Step 2: Disconnect the power cord if you want to shut down the switch.
12VDC DC Jack
Step 1: Connect the supplied AC to DC power adapter to the receptacle on
the topside of the switch.
Step 2: Connect the power cord to the AC to DC power adapter and attach
the plug into a standard AC outlet with the appropriate AC voltage.
Page 16
Hardened Ethernet Switch
Alarms for Power Failure
Step 1: There are two pins on the terminal block are used for power failure
detection. It provides the normally closed output when the power source is active. Use this as a dry contact application to send a signal for power failure detection.
Power Input Assignment Power3 12VDC DC Jack
12-48VDC
Power2
Power Ground
12-48VDC
Power1
Power Ground
Earth Ground
Terminal Block
Relay Alarm Assignment
FAULT
*Relay warning signal disable for following:
The relay contact closes if Power1 and Power2 are both failed but Power3 on.
The relay contact closes if Power3 is failed but Power1 and Power2 are both on.
Special note: The relay output is normal open position when there is no power to the switch. Please do not connect any power source to this terminal to prevent the shortage to your power supply.
16
Page 17
Hardened Ethernet Switch
17
Connecting to Your Network
Cable Type & Length
It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements.
Cable pecifications S Speed
Connector Port Speed
Half/Full Duplex
Cable
Max. Distance
10Base-T RJ-45 10/20 Mbps 2-pair
UTP/STP Cat. 3, 4, 5
100 m
100Base-TX RJ-45 100/200 Mbps 2-pair
UTP/STP Cat. 5
100 m
100Base-FX SC, ST 200 Mbps MMF (50 or
62.5μm)
2 km
100Base-FX SC, ST 200 Mbps SMF (9 or
10μm)
20, 40, or 75 km
100Base-BX SC 200 Mbps SMF (9 or
10μm)
20 or 40 km
Page 18
Hardened Ethernet Switch
18
Cabling
Step 1: First, ensure the power of the switch and end devices are turned off.
<Note> Always ensure that the power is off before any installation.
Step 2: Prepare cable with corresponding connectors for each type of port
in use.
Step 3: Consult the previous section for cabling requirements based on
connectors and speed.
Step 4: Connect one end of the cable to the switch and the other end to a
desired device.
Step 5: Once the connections between two end devices are made
successfully, turn on the power and the switch is operational.
Page 19
Hardened Ethernet Switch
19
Specifications
Hardened Ethernet Switch
10/100Base-TX auto-negotiating ports with RJ-45 connectors, 100Base-FX/BX fiber ports
Applicable Standards
IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX/FX
Switching Method Store-and-Forward Forwarding Rate
10Base-T: 100Base-TX: 100Base-FX/BX:
10 / 20Mbps half / full-duplex 100 / 200Mbps half / full-duplex 200Mbps full-duplex
Performance 14,880pps for 10Mbps
148,810pps for 100Mbps
Cable
10Base-T: 100Base-TX:
100Base-FX: 100Base-BX:
2-pair UTP/STP Cat. 3, 4, 5 2-pair UTP/STP Cat. 5 Up to 100m (328ft) MMF (50 or 62.5μm), SMF (9 or10μm) SMF (9 or10μm)
LED Indicators Per unit –
Power status (Power 1, Power 2, Power 3) Fault
Per port –
10/100TX or 100FX/BX - LINK/ACT, 100
Dimensions 60mm (W) × 125mm (D) × 145mm (H)
(2.36” (W) × 4.92” (D) × 5.7” (H))
Net Weight 1Kg (2.2lbs.) Power Terminal Block: 12-48VDC
DC Jack: 12VDC, External AC/DC required
Operating Voltage & Max. Current Consumption
0.5A @ 12VDC, 0.25A @ 24VDC, 0.125A @ 48VDC
Power Consumption
6W Max.
Operating Temperature
-40°C to 75 (-40 to 167) Tested for functional operation @
-40 to 85 (-40 to 185)
Storage Temperature
-40°C to 85°C (-40 to 185℉)
Humidity 5%-95% non-condensing
EMI
FCC Part 15, Class A EN61000-6-4
EN55022 EN61000-3-2
Page 20
Hardened Ethernet Switch
20
EN61000-3-3
EMS
EN61000-6-2
EN61000-4-2 (ESD Standard) EN61000-4-3 (Radiated FRI Standards) EN61000-4-4 (Burst Standards) EN61000-4-5 (Surge Standards) EN61000-4-6 (Induced RFI Standards) EN61000-4-8 (Magnetic Field Standards)
Environmental Test Compliance
IEC60068-2-6 Fc (Vibration Resistance) IEC60068-2-27 Ea (Shock) IEC60068-2-32 Ed (Free Fall) IEC61850-3 and IEEE1613 environmental requirements for substation and power automation systems EN50121-4 environmental requirements for railway applications NEMA TS1/2 Environmental requirements for traffic control equipments
Page 21
Hardened Ethernet Switch
Appendix A – Connector Pinouts
Pin arrangement of RJ-45 connectors:
RJ-45 Connector and Cable Pins
The following table lists the pinout of 10/100Base-TX ports.
Pin Regular Ports Uplink port
1 Output Transmit Data + Input Receive Data + 2 Output Transmit Data - Input Receive Data ­3 Input Receive Data + Output Transmit Data + 4 NC NC 5 NC NC 6 Input Receive Data - Output Transmit Data ­7 NC NC 8 NC NC