This quick start guide describes how to install and use the
Hardened Gigabit Ethernet Switch. Capable of operating at
temperature extremes of -40°C to 75°C, this is the Switch of
choice for harsh environments constrained by space.
Physical Description
The Port Status LEDs
1
Page 2
EX42905/EX42914 series www.etherwan.com
LED State Indication
PWR
10/100
1000
Steady Device is powered up.
Off Device is powered off.
Steady
Flashing Transmitting or receiving data.
Steady A valid network connection established at 1000Mbps.
Off The port is transferring at 10Mbps If this LED is dark.
A valid network connection established at 10 or
100Mbps.
The Terminal Block and Power Input
The Terminal Block
PWRPower Input
GND Power Ground
Earth Ground
DC Terminal Block Power Input: The DC Terminal Block
power input can be used to power up this Switch / Media
Converter.
CAUTION: This equipment is designed to permit the
connection of the earthed conductor of the DC supply circuit
to the earthing conductor at the equipment.
If this connection is made, all of the following conditions must
be met:
This equipment shall be connected to directly to the DC supply
system earthing electrode conductor or to a bonding jumper from
an earthing terminal bar or bus to which the DC supply system
earthing electrode conductor is connected.
2
Page 3
EX42905/EX42914 series www.etherwan.com
This equipment shall be located in the same immediate area
(such as, adjacent cabinets) as any other equipment that has a
connection between the earthed conductor of the same DC
supply circuit and the earthing conductor, and also the point of
earthing of the DC system. The DC system shall not be earthed
elsewhere.
The DC supply source is to be located within the same premises
as the equipment.
Switching or disconnecting devices shall not be in the earthed
circuit conductor between the DC source and the point of
connection of the earthing electrode conductor.
The 10/100/1000Base-TX and 1000Base-SX/LX/BX
Connectors
1. The 10/100/1000Base-TX Connections
The following lists the pinouts of 10/100/1000Base-TX ports.
Pin Regular PortsUplink port
1
TP0+Transmit and Receive Data 0 +
2
TP0-Transmit and Receive Data 0 -
3
TP1+Transmit and Receive Data 1 +
4
TP2+Transmit and Receive Data 2 +
5
TP2-Transmit and Receive Data 2 -
6
TP1-Transmit and Receive Data 1 -
7
TP3+Transmit and Receive Data 3 +
8
TP3-Transmit and Receive Data 3 -
3
Page 4
EX42905/EX42914 series www.etherwan.com
2. The 1000Base-SX/LX Connections
The fiber port pinouts: The Tx (transmit) port of device I is
connected to the Rx (receive) port of device II, and the Rx
(receive) port of device I to the Tx (transmit) port of device II.
3. The WDM 1000Base-BX Connections
The fiber port pinouts: Only one Single mode or Multi mode
optical fiber is required to transmit and receive data.
Functional Description
Complies with EN61000-6-2 & EN61000-6-4 EMC Generic
standard immunity for industrial environment.
Supports 802.3/802.3u/802.3ab/802.3z/802.3x.
Auto-negotiation: 10/100/1000Mbps, Full/Half-duplex. Auto
MDI/MDIX.
1000Base-SX/LX: Multi mode SC or ST type, Single mode SC
or ST type. 1000Base-BX: WDM Multi mode or Single mode
SC type.
Supports 8192 MAC addresses, 1M bits buffer memory.
Jumbo frame supported up to 10K bytes.
IEEE802.3az Energy Efficient Ethernet (EEE) supported.
Quality of Service (QoS) supported based on layer 2
priorities.
Power consumption: 6.5W Max. 0.25A @ 24VDC.
Power supply: DC Terminal Block power input, 12-48VDC.
4
Page 5
EX42905/EX42914 series www.etherwan.com
-40°C to 75°C (-40°F to 167°F) operating temperature range.
Tested for functional operation @ -40°C to 85°C (-40°F to
185°F).
Metal compact DIN-Rail industrial case design.
5
Page 6
EX42905/EX42914 series www.etherwan.com
Assembly, Startup, and Dismantling
Assembly: Place the device on the DIN-Rail from above using
the slot. Push the front of the device toward the mounting
surface until it audibly snaps into place.
Startup: Connect the supply voltage to start up the device via
the terminal block.
Dismantling: Pull out the lower edge and then remove the
device from the DIN-Rail.
6
Page 7
EX42905/EX42914 series www.etherwan.com
Preface
A member of the growing family of rugged switches, this
switch addresses a need for a smaller switch. This switch
provides an affordable solution for rugged and outdoor
environment, transportation road-side cabinet, industrial floor
shop, multitenant dwellings or Fiber To The Home (FTTH)
applications. Capable of operating at temperature extremes of
-40°C to 75°C, this is the switch of choice for harsh
environments constrained by space.
Plug-and-Play Solution:
The switch is a plug-and-play Gigabit Ethernet Switch in
compact size. It doesn't have any complicated software to set
up.
This manual describes how to install and use the hardened
compact Gigabit Ethernet Switch. This switch integrates full
wire speed switching technology. This switch brings the
answer to complicated hardened networking environments.
To get the most out of this manual, you should have an
understanding of Ethernet networking concepts.
In this manual, you will find:
Features on the switch
Illustrative LED functions
Installation instructions
Specifications
7
Page 8
EX42905/EX42914 series www.etherwan.com
Table of Contents
QUICK START GUIDE 1
PHYSICAL DESCRIPTION 1
The Port Status LEDs 1
The Terminal Block and Power Input 2
The 10/100/1000Base-TX and 1000Base-SX/LX/BX Connectors 3
FUNCTIONAL DESCRIPTION 4
ASSEMBLY,STARTUP, AND DISMANTLING 6
SELECTING A SITE FOR THE SWITCH 13
DINRAIL MOUNTING 14
CONNECTING TO POWER 15
DC Terminal Block Power Inputs 15
CONNECTING TO YOUR NETWORK 17
Cable Type & Length 17
Cabling 18
SPECIFICATIONS 19
8
Page 9
EX42905/EX42914 series www.etherwan.com
Product Overview
Hardened Gigabit Ethernet Switch
Package Contents
When you unpack the product package, you shall find the
items listed below. Please inspect the contents, and report
any apparent damage or missing items immediately to your
authorized reseller.
This Switch
User’s Manual
9
Page 10
EX42905/EX42914 series www.etherwan.com
Product Highlights
Basic Features
Complies with EN61000-6-2 & EN61000-6-4 EMC Generic
standard immunity for industrial environment.
Supports 802.3/802.3u/802.3ab/802.3z/802.3x.
Auto-negotiation: 10/100/1000Mbps, Full/Half-duplex. Auto
MDI/MDIX.
1000Base-SX/LX: Multi mode SC or ST type, Single mode SC
or ST type. 1000Base-BX: WDM Multi mode or Single mode
SC type.
Supports 8192 MAC addresses, 1M bits buffer memory.
Jumbo frame supported up to 10K bytes.
IEEE802.3az Energy Efficient Ethernet (EEE) supported.
Quality of Service (QoS) supported based on layer 2
priorities.
802.1Q VLAN Tag Based Priority, Class of Service.
Output Queue Schedule Mode: Weighted Round Robin
(WRR) with 4 priority queues.
The configurations of QoS are as below:
CoS Field ValuePacket CountPriority
0 or 1 1 Lowest
2 or 3 2 Low
4 or 5 4 High
6 or 7 8 Highest
Power consumption: 6.5W Max. 0.25A @ 24VDC.
Power supply: DC Terminal Block power input, 12-48VDC.
-40°C to 75°C (-40°F to 167°F) operating temperature range.
Tested for functional operation @ -40°C to 85°C (-40°F to
185°F).
Metal compact DIN-Rail industrial case design.
10
Page 11
EX42905/EX42914 series www.etherwan.com
Front Panel Display
Power Status (PWR)
This LED comes on when the switch is properly connected to
power and turned on.
Port Status LEDs
The LEDs display status for each respective port.
LED State Indication
PWR
10/100
1000
Steady Device is powered up.
Off Device is powered off.
Steady
Flashing Transmitting or receiving data.
Steady A valid network connection established at 1000Mbps.
Off The port is transferring at 10Mbps If this LED is dark.
A valid network connection established at 10 or
100Mbps.
11
Page 12
EX42905/EX42914 series www.etherwan.com
Physical Ports
This switch provides:
Five 10/100/1000Base-TX ports
Four 10/100/1000Base-TX ports + one 1000Base-SX/LX/BX
port
Connectivity:
RJ-45 connectors
SC or ST connector on 1000Base-SX/LX fiber port
SC connector on 1000Base-BX fiber port
12
Page 13
EX42905/EX42914 series www.etherwan.com
Installation
This chapter gives step-by-step instructions about how to
install the switch:
Selecting a Site for the Switch
As with any electric device, you should place the switch
where it will not be subjected to extreme temperatures,
humidity, or electromagnetic interference. Specifically, the site
you select should meet the following requirements:
The ambient temperature should be between -40 to 75
degrees Celsius.
The relative humidity should be less than 95 percent,
non-condensing.
Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards.
Make sure that the switch receives adequate ventilation. Do
not block the ventilation holes on each side of the switch
The power outlet should be within 1.8 meters of the switch.
13
Page 14
EX42905/EX42914 series www.etherwan.com
DIN Rail Mounting
Installation: Place the switch on the DIN rail from above using
the slot. Push the front of the switch toward the mounting
surface until it audibly snaps into place.
Removal: Pull out the lower edge and then remove the switch
from the DIN rail.
14
Page 15
EX42905/EX42914 series www.etherwan.com
Connecting to Power
DC Terminal Block Power Inputs
Step 1: Connect the DC power cord to the plug-able terminal block on the
Step 2: Disconnect the power cord if you want to shut down the switch.
switch, and then plug it into a standard DC outlet.
The Terminal Block
PWRPower Input
GND Power Ground
Earth Ground
CAUTION: This equipment is designed to permit the
connection of the earthed conductor of the DC supply circuit
to the earthing conductor at the equipment.
If this connection is made, all of the following conditions must
be met:
This equipment shall be connected to directly to the DC
supply system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the DC
supply system earthing electrode conductor is connected.
This equipment shall be located in the same immediate area
(such as, adjacent cabinets) as any other equipment that has
a connection between the earthed conductor of the same DC
supply circuit and the earthing conductor, and also the point of
15
Page 16
EX42905/EX42914 series www.etherwan.com
earthing of the DC system. The DC system shall not be
earthed elsewhere.
The DC supply source is to be located within the same
premises as the equipment.
Switching or disconnecting devices shall not be in the earthed
circuit conductor between the DC source and the point of
connection of the earthing electrode conductor.
16
Page 17
EX42905/EX42914 series www.etherwan.com
Connecting to Your Network
Cable Type & Length
It is necessary to follow the cable specifications below when
connecting the switch to your network. Use appropriate
cables that meet your speed and cabling requirements.
Cable Specifications
Speed Connector Port Speed
Half/Full Duplex
10Base-T RJ-45 10/20 Mbps 2-pair UTP/STP
100Base-TX RJ-45 100/200 Mbps 2-pair UTP/STP
1000Base-T RJ-45 2000 Mbps 4-pair UTP/STP
1000Base-SX SC, ST 2000 Mbps MMF (50 or
1000Base-SX SC 2000 Mbps MMF (50 or
1000Base-LX SC 2000 Mbps SMF (9 or
1000Base-BX SC 2000 Mbps SMF (9 or
Cable Max.
Distance
100 m
Cat. 3, 4, 5
100 m
Cat. 5
100 m
Cat. 5
550 m
62.5μm)
2 km
62.5μm)
10 or 20 km
10μm)
20 km
10μm)
17
Page 18
EX42905/EX42914 series www.etherwan.com
Cabling
Step 1: First, ensure the power of the switch and end devices are turned off.
<Note>Always ensure that the power is off before any installation.
Step 2: Prepare cable with corresponding connectors for each type of port
<Note>To connect two regular RJ-45 ports between switches or hubs, you need a
Step 3: Consult the previous section for cabling requirements based on
Step 4: Connect one end of the cable to the switch and the other end to a
Step 5: Once the connections between two end devices are made
in use.
straight or cross-over cable.
connectors and speed.
desired device.
successfully, turn on the power and the switch is operational.