EtherWAN EX42200 Quick Start Manual

Page 1
EX42200 www.etherwan.com
Quick Start Guide
This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. Capable of operating at
temperature extremes of -40°C to +75°C, this is the switch of choice for harsh environments constrained by space.
The Terminal Block and Power Inputs
Power Input Assignment
18~57VDC
Power1
Power Ground
18~57VDC
Power2
Power Ground
Earth Ground
Terminal Block
Relay Output Rating 1A @ 250VAC Relay Alarm Assignment
Default is Power1 and Power2 both off. Point 1 & 2 is close and Point 2 & 3 is open.
DC Terminal Block Power Inputs: There are two pairs of power inputs can be used to power up this switch. Redundant power supplies function is supported.
1
Page 2
EX42200 www.etherwan.com
The 10/100Base-TX and 100Base-FX/BX Connectors
1. The 10/100Base-TX Connections
The following lists the pinouts of 10/100Base-TX ports.
Pin Signal Name Signal Definition
1
TD Output Transmit Data
2
TD Output Transmit Data
3
RD Input Receive Data
4 PoE
Positive (VCC+)
5 PoE
Positive (VCC+)
6
RD Input Receive Data
7 PoE
Negative (VCC-)
8 PoE
Negative (VCC-)
2. The 100Base-FX Connections
The fiber port pinouts: The Tx (transmit) port of device I is connected to the Rx (receive) port of device II, and the Rx
(receive) port of device I to the Tx (transmit) port of device II.
3. The WDM 100Base-BX Connections
The fiber port pinouts: Only one single optical fiber is required to transmit and receive data.
2
Page 3
EX42200 www.etherwan.com
The Port Status LEDs
3
Page 4
EX42200 www.etherwan.com
4
LED State Indication
Steady Power on.
Power1
Power2
Off Power off.
Steady Power redundant system failure occurred.
Alarm
Off Power redundant system failure is not occurred.
10/100Base-TX
Steady A valid network connection established.
LINK/ACT
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady Valid port connection at 100Mbps.
10/100
Off Valid port connection at 10Mbps.
Steady Powered device (PD) is connected.
PoE
Off Powered device (PD) is disconnected.
100Base-FX/BX
Steady A valid network connection established.
LINK/ACT
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady Valid port connection at 100Mbps.
100
Off No valid port connection at 10Mbps.
Page 5
EX42200 www.etherwan.com
5
Functional Description
Meets EN61000-6-2 & EN61000-6-4 EMC Generic
Standard Immunity for industrial environment.
Supports IEEE802.3at Power over Ethernet (PoE)
Power Sourcing Equipment (PSE).
Port 1 to 4 support PoE function, IEEE802.3at Power
over Ethernet (PoE) and 10/100Base-TX.
Up to 30W per PoE port, 55VDC, 600mA Max.  Supports IEEE802.3/802.3u/802.3x. 10/100Mbps,
Full/Half-duplex, Auto-Negotiation, Auto MDI/MDIX.
100Base-FX: Multi/Single mode SC or ST type.
100Base-BX: WDM Multi/Single mode SC type.
Supports 2048 MAC addresses. Provides 448K bits
buffer memory.
Alarms for power failure by relay output. Fully supports
normal open and normal close.
Redundant dual 18 to 57VDC Terminal Block power
inputs.
Device power consumption: 14W Max. (without PoE).
PoE power budget: 120W Max.
Operating temperature ranges from -40℃ to 75
(-40 to 167℉), tested for functional operation @ -40 to 85 (-40 to 185℉).
Supports DIN-Rail installation.
Assembly, Startup, and Dismantling
Assembly: Place the switch on the DIN rail from above
using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place.
Startup: Connect the supply voltage to start up the
switch via the terminal block.
Dismantling: Pull out the lower edge and then remove
the switch from the DIN rail.
Page 6
EX42200 www.etherwan.com
6
Page 7
EX42200 www.etherwan.com
7
Preface
A member of the growing family of rugged switches, this Hardened PoE Ethernet Switch addresses a need for a smaller switch. This switch provides an affordable solution for rugged and outdoor environment, transportation road-side cabinet, industrial floor shop, multitenant dwellings or Fiber To The Home (FTTH) applications. Capable of operating at
temperature extremes of -40°C to +75°C, this is the switch of choice for harsh environments constrained by space.
Port 1 to port 4 on this Switch supports IEEE802.3at Power over Ethernet (PoE) Power Sourcing Equipment (PSE) and can detect an IEEE802.3at compliant Powered Device (PD). Using external 18~57VDC power inputs through Terminal Block, data and power can be transmitted to a Powered Device (PD) over the same twisted-pair Ethernet cable through port 1 to port 4 on the Switch.
This manual describes how to install and use the Hardened PoE Ethernet Switch. This switch integrates full wire speed switching technology. This switch brings the answer to complicated Industrial networking environments.
To get the most out of this manual, you should have an understanding of Ethernet networking concepts.
In this manual, you will find:
Features on the switch  Illustrative LED functions  Installation instructions  Specifications
Page 8
EX42200 www.etherwan.com
8
Table of Contents
QUICK START GUIDE 1
PHYSICAL DESCRIPTION 1
The Terminal Block and Power Inputs 1 The 10/100Base-TX and 100Base-FX/BX Connectors 2 The Port Status LEDs 3
FUNCTIONAL DESCRIPTION 5 ASSEMBLY, STARTUP, AND DISMANTLING 5
P
REFACE 7
T
ABLE OF CONTENTS 8
P
RODUCT OVERVIEW 9
HARDENED POE ETHERNET SWITCH 9 PACKAGE CONTENTS 9 PRODUCT HIGHLIGHTS 10
Basic Features 10
FRONT PANEL DISPLAY 11 PHYSICAL PORTS 13
INSTALLATION 14
SELECTING A SITE FOR THE SWITCH 14 DIN RAIL MOUNTING 15 CONNECTING TO POWER 16
Redundant DC Terminal Block Power Inputs 16 Alarms for Power and Port Link Failure 17
CONNECTING TO YOUR NETWORK 18
Cable Type & Length 18 Cabling 19
SPECIFICATIONS 20
Page 9
EX42200 www.etherwan.com
Product Overview
Hardened PoE Ethernet Switch
Package Contents
When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller.
This Switch
User’s Manual
9
Page 10
EX42200 www.etherwan.com
10
Product Highlights
Basic Features
Meets EN61000-6-2 & EN61000-6-4 EMC Generic
Standard Immunity for industrial environment.
Supports IEEE802.3at Power over Ethernet (PoE)
Power Sourcing Equipment (PSE).
Port 1 to 4 support PoE function, IEEE802.3at Power
over Ethernet (PoE) and 10/100Base-TX.
Up to 30W per PoE port, 55VDC, 600mA Max.  Supports IEEE802.3/802.3u/802.3x. 10/100Mbps,
Full/Half-duplex, Auto-Negotiation, Auto MDI/MDIX.
100Base-FX: Multi/Single mode SC or ST type.
100Base-BX: WDM Multi/Single mode SC type.
Supports 2048 MAC addresses. Provides 448K bits
buffer memory.
Alarms for power failure by relay output. Fully supports
normal open and normal close.
Redundant dual 18 to 57VDC Terminal Block power
inputs.
Device power consumption: 14W Max. (without PoE).
PoE power budget: 120W Max.
Operating temperature ranges from -40℃ to 75
(-40 to 167℉), tested for functional operation @ -40 to 85 (-40 to 185℉).
Supports DIN-Rail installation.
Page 11
EX42200 www.etherwan.com
Front Panel Display
11
Page 12
EX42200 www.etherwan.com
12
Status LEDs
LED State Indication
Steady Power on.
Power1
Power2
Off Power off.
Steady Power redundant system failure occurred.
Alarm
Off Power redundant system failure is not occurred.
10/100Base-TX
Steady A valid network connection established.
LINK/ACT
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady Valid port connection at 100Mbps.
10/100
Off Valid port connection at 10Mbps.
Steady Powered device (PD) is connected.
PoE
Off Powered device (PD) is disconnected.
100Base-FX/BX
Steady A valid network connection established.
LINK/ACT
Flashing
Transmitting or receiving data.
ACT stands for ACTIVITY.
Steady Valid port connection at 100Mbps.
100
Off No valid port connection at 10Mbps.
Page 13
EX42200 www.etherwan.com
13
Physical Ports
This switch provides:
Five 10/100Base-TX ports  Four 10/100Base-TX ports + one 100Base-FX/BX port
CONNECTIVITY
RJ-45 connector on TX ports  SC or ST connector on 100Base-FX fiber port  SC connector on 100Base-BX fiber port
Page 14
EX42200 www.etherwan.com
14
Installation
This chapter gives step-by-step instructions about how to install the switch:
Selecting a Site for the Switch
As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
The ambient temperature should be between -40 to 75
degrees Celsius.
The relative humidity should be less than 95 percent,
non-condensing.
Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards.
Make sure that the switch receives adequate ventilation.
Do not block the ventilation holes on each side of the switch
The power outlet should be within 1.8 meters of the
switch.
Page 15
EX42200 www.etherwan.com
DIN Rail Mounting
Fix the DIN rail attachment plate to the back panel of the switch.
Installation: Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place.
Removal: Pull out the lower edge and then remove the switch from the DIN rail.
15
Page 16
EX42200 www.etherwan.com
Connecting to Power
Redundant DC Terminal Block Power Inputs
There are two pairs of power inputs can be used to power up this device. You only need to have one power input connected to run the switch.
Step 1: Connect the DC power cord to the plug-able terminal block on the
switch, and then plug it into a standard DC outlet.
Step 2: Disconnect the power cord if you want to shut down the switch.
16
Page 17
EX42200 www.etherwan.com
Alarms for Power and Port Link Failure
Step 1: There are three pins on the terminal block are used for power failure
detection. It fully supports normal open and normal close. Use this as a dry contact application to send a signal for power failure detection.
Power Input Assignment
18~57VDC
Power1
Power Ground
18~57VDC
Power2
Power Ground
Earth Ground
Terminal Block
Relay Output Rating 1A @ 250VAC Relay Alarm Assignment
Default is Power1 and Power2 both off. Point 1 & 2 is close and Point 2 & 3 is open.
Relay Contact Power1 Power2 Point 1 & 2 Point 2 & 3
Start Alarm Off Off Close Open
Start Alarm Off On Close Open
Start Alarm On Off Close Open
Non-Alarm On On Open Close
17
Page 18
EX42200 www.etherwan.com
18
Connecting to Your Network
Cable Type & Length
It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements.
Cable S ecifications p
Speed
Connector Port Speed
Half/Full Duplex
Cable
Max. Distance
10Base-T RJ-45 10/20 Mbps 2-pair
UTP/STP Cat. 3, 4, 5
100 m
100Base-TX RJ-45 100/200 Mbps 2-pair
UTP/STP Cat. 5
100 m
100Base-FX SC, ST 200 Mbps MMF (50 or
62.5μm)
2 km
100Base-FX SC, ST 200 Mbps SMF (9 or
10μm)
20 or 40 km
100Base-BX SC 200 Mbps MMF (50 or
62.5μm)
2 or 5 km
100Base-BX SC 200 Mbps SMF (9 or
10μm)
20 or 40 km
Page 19
EX42200 www.etherwan.com
19
Cabling
Step 1: First, ensure the power of the switch and end devices are turned off.
<Note> Always ensure that the power is off before any installation.
Step 2: Prepare cable with corresponding connectors for each type of port
in use.
Step 3: Consult the previous section for cabling requirements based on
connectors and speed.
Step 4: Connect one end of the cable to the switch and the other end to a
desired device.
Step 5: Once the connections between two end devices are made
successfully, turn on the power and the switch is operational.
Page 20
EX42200 www.etherwan.com
20
Specifications
Hardened PoE Ethernet Switch
10/100Base-TX auto-negotiating ports with RJ-45 connectors, 100Base-FX/BX fiber port
Applicable Standards
IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX/FX
Switching Method Store-and-Forward Forwarding Rate
10Base-T: 100Base-TX: 100Base-FX/BX:
10 / 20Mbps half / full-duplex 100 / 200Mbps half / full-duplex 200Mbps full-duplex
Performance 14,880pps for 10Mbps
148,810pps for 100Mbps
Cable
10Base-T: 100Base-TX:
100Base-FX/BX:
4-pair UTP/STP Cat. 3, 4, 5 4-pair UTP/STP Cat. 5 Up to 100m (328ft.) MMF (50 or 62.5μm), SMF (9 or 10μm)
LED Indicators Per unit –
Power status (Power 1, Power 2), Alarm
Per port –
10/100TX - LINK/ACT, 100, PoE 100FX/BX - LINK/ACT, 100
Dimensions 61mm (W) × 73mm (D) × 110mm (H)
(2.4” (W) x 2.87” (D) x 4.33”(H))
Net Weight 0.6Kg (1.32lbs.) Power Terminal Block: 18~57VDC Power Consumption
Device: 14W Max. (without PoE)
PoE power budget: 120W Max.
Operating Temperature
-40 to 75 (-40 to 167) Tested @ -40 to 85 (-40 to 185℉)
Storage Tem per ature
-40 to 85 (-40 to 185)
Humidity 5%-95% non-condensing
EMI
FCC Part 15, Class A CE, VCCI Class A EN61000-6-4
EN55022 EN61000-3-2 EN61000-3-3
EMS
EN61000-6-2
EN61000-4-2 (ESD Standard)
Page 21
EX42200 www.etherwan.com
21
EN61000-4-3 (Radiated FRI Standards) EN61000-4-4 (Burst Standards) EN61000-4-5 (Surge Standards) EN61000-4-6 (Induced RFI Standards) EN61000-4-8 (Magnetic Field Standards)
Environmental Test Complia nc e
IEC60068-2-6 Fc (Vibration Resistance) IEC60068-2-27 Ea (Shock) FED STD 101C Method 5007.1 (Free Fall with package)