EtherWan EX32905 series, EX32914 series Quick Start Guide

Page 1
EX32905/EX32914 series www.etherwan.com

Quick Start Guide

This quick start guide describes how to install and use the Industrial Gigabit Ethernet Switch. Capable of operating at
temperature extremes of -10°C to 60°C, this is the Switch of choice for harsh environments constrained by space.

Physical Description

1
Page 2
EX32905/EX32914 series www.etherwan.com
LED State Indication PWR
10/100
1000
Steady Device is powered up. Off Device is powered off.
Steady
Flashing Transmitting or receiving data. Steady A valid network connection established at 1000Mbps. Off The port is transferring at 10Mbps If this LED is dark.
A valid network connection established at 10 or 100Mbps.

The Terminal Block and Power Input

The Terminal Block PWR Power Input GND Power Ground
Earth Ground
DC Terminal Block Power Input: The DC Terminal Block power input can be used to power up this Switch / Media Converter.
CAUTION: This equipment is designed to permit the
connection of the earthed conductor of the DC supply circuit to the earthing conductor at the equipment. If this connection is made, all of the following conditions must be met:
This equipment shall be connected to directly to the DC supply
system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode conductor is connected.
2
Page 3
EX32905/EX32914 series www.etherwan.com
This equipment shall be located in the same immediate area
(such as, adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor, and also the point of earthing of the DC system. The DC system shall not be earthed elsewhere.
The DC supply source is to be located within the same premises
as the equipment.
Switching or disconnecting devices shall not be in the earthed
circuit conductor between the DC source and the point of connection of the earthing electrode conductor.

The 10/100/1000Base-TX and 1000Base-SX/LX/BX Connectors

1. The 10/100/1000Base-TX Connections
The following lists the pinouts of 10/100/1000Base-TX ports.
Pin Regular Ports Uplink port
1
TP0 Transmit and Receive Data 0
2
TP0 Transmit and Receive Data 0
3
TP1 Transmit and Receive Data 1
4
TP2 Transmit and Receive Data 2
5
TP2 Transmit and Receive Data 2
6
TP1 Transmit and Receive Data 1
7
TP3 Transmit and Receive Data 3
8
TP3 Transmit and Receive Data 3
3
Page 4
EX32905/EX32914 series www.etherwan.com
2. The 1000Base-SX/LX Connections
The fiber port pinouts: The Tx (transmit) port of device I is connected to the Rx (receive) port of device II, and the Rx
(receive) port of device I to the Tx (transmit) port of device II.
3. The WDM 1000Base-BX Connections
The fiber port pinouts: Only one Single mode or Multi mode
optical fiber is required to transmit and receive data.

Functional Description

Complies with EN61000-6-2 & EN61000-6-4 EMC Generic
standard immunity for industrial environment.
Supports 802.3/802.3u/802.3ab/802.3z/802.3x.
Auto-negotiation: 10/100/1000Mbps, Full/Half-duplex. Auto MDI/MDIX.
1000Base-SX/LX: Multi mode SC or ST type, Single mode SC
or ST type. 1000Base-BX: WDM Multi mode or Single mode SC type.
Supports 8192 MAC addresses, 1M bits buffer memory. Jumbo frame supported up to 10K bytes. IEEE802.3az Energy Efficient Ethernet (EEE) supported. Quality of Service (QoS) supported based on layer 2
priorities.
Power consumption: 6.5W Max. 0.25A @ 24VDC. Power supply: DC Terminal Block power input, 12-48VDC.
4
Page 5
EX32905/EX32914 series www.etherwan.com
-10°C to 60°C (14°F to 140°F) operating temperature range.
Tested for functional operation @ -20°C to 70°C (-4°F to 158°F).
Metal compact DIN-Rail industrial case design.
5
Page 6
EX32905/EX32914 series www.etherwan.com

Assembly, Startup, and Dismantling

Assembly: Place the device on the DIN-Rail from above using
the slot. Push the front of the device toward the mounting surface until it audibly snaps into place.
Startup: Connect the supply voltage to start up the device via
the terminal block.
Dismantling: Pull out the lower edge and then remove the
device from the DIN-Rail.
6
Page 7
EX32905/EX32914 series www.etherwan.com

Preface

A member of the growing family of rugged switches, this switch addresses a need for a smaller switch. This switch provides an affordable solution for rugged and outdoor environment, transportation road-side cabinet, industrial floor shop, multitenant dwellings or Fiber To The Home (FTTH) applications. Capable of operating at temperature extremes of
-10°C to 60°C, this is the switch of choice for harsh environments constrained by space.
Plug-and-Play Solution: The switch is a plug-and-play Gigabit Ethernet Switch in compact size. It doesn't have any complicated software to set up.
This manual describes how to install and use the industrial compact Gigabit Ethernet Switch. This switch integrates full wire speed switching technology. This switch brings the answer to complicated hardened networking environments.
To get the most out of this manual, you should have an understanding of Ethernet networking concepts.
In this manual, you will find:
Features on the switch Illustrative LED functions Installation instructions Specifications
7
Page 8
EX32905/EX32914 series www.etherwan.com

Table of Contents

QUICK START GUIDE 1
PHYSICAL DESCRIPTION 1
The Port Status LEDs 1 The Terminal Block and Power Input 2 The 10/100/1000Base-TX and 1000Base-SX/LX/BX Connectors 3
FUNCTIONAL DESCRIPTION 4 ASSEMBLY, STARTUP, AND DISMANTLING 6
REFACE 7
P T
ABLE OF CONTENTS 8 RODUCT OVERVIEW 9
P
INDUSTRIAL GIGABIT ETHERNET SWITCH 9 PACKAGE CONTENTS 9 PRODUCT HIGHLIGHTS 10
Basic Features 10
FRONT PANEL DISPLAY 11 PHYSICAL PORTS 12
INSTALLATION 13
SELECTING A SITE FOR THE SWITCH 13 DIN RAIL MOUNTING 14 CONNECTING TO POWER 15
DC Terminal Block Power Inputs 15
CONNECTING TO YOUR NETWORK 17
Cable Type & Length 17 Cabling 18
SPECIFICATIONS 19
8
Page 9
EX32905/EX32914 series www.etherwan.com

Product Overview

Industrial Gigabit Ethernet Switch

Package Contents

When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller.
This Switch User’s Manual
9
Page 10
EX32905/EX32914 series www.etherwan.com

Product Highlights

Basic Features

Complies with EN61000-6-2 & EN61000-6-4 EMC Generic
standard immunity for industrial environment.
Supports 802.3/802.3u/802.3ab/802.3z/802.3x.
Auto-negotiation: 10/100/1000Mbps, Full/Half-duplex. Auto MDI/MDIX.
1000Base-SX/LX: Multi mode SC or ST type, Single mode SC
or ST type. 1000Base-BX: WDM Multi mode or Single mode SC type.
Supports 8192 MAC addresses, 1M bits buffer memory. Jumbo frame supported up to 10K bytes. IEEE802.3az Energy Efficient Ethernet (EEE) supported. Quality of Service (QoS) supported based on layer 2
priorities.
802.1Q VLAN Tag Based Priority, Class of Service. Output Queue Schedule Mode: Weighted Round Robin
(WRR) with 4 priority queues.
The configurations of QoS are as below:
CoS Field Value Packet Count Priority
0 or 1 1 Lowest
2 or 3 2 Low
4 or 5 4 High
6 or 7 8 Highest
Power consumption: 6.5W Max. 0.25A @ 24VDC. Power supply: DC Terminal Block power input, 12-48VDC. -10°C to 60°C (14°F to 140°F) operating temperature range.
Tested for functional operation @ -20°C to 70°C (-4°F to 158°F).
Metal compact DIN-Rail industrial case design.
10
Page 11
EX32905/EX32914 series www.etherwan.com

Front Panel Display

 Power Status (PWR)
This LED comes on when the switch is properly connected to power and turned on.
 Port Status LEDs
The LEDs display status for each respective port.
LED State Indication PWR
10/100
1000
Steady Device is powered up. Off Device is powered off.
Steady
Flashing Transmitting or receiving data. Steady A valid network connection established at 1000Mbps. Off The port is transferring at 10Mbps If this LED is dark.
A valid network connection established at 10 or 100Mbps.
11
Page 12
EX32905/EX32914 series www.etherwan.com

Physical Ports

This switch provides:
Five 10/100/1000Base-TX ports Four 10/100/1000Base-TX ports + one 1000Base-SX/LX/BX
port
Connectivity:
RJ-45 connectors SC or ST connector on 1000Base-SX/LX fiber port SC connector on 1000Base-BX fiber port
12
Page 13
EX32905/EX32914 series www.etherwan.com

Installation

This chapter gives step-by-step instructions about how to install the switch:

Selecting a Site for the Switch

As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
The ambient temperature should be between -10 to 60
degrees Celsius.
The relative humidity should be less than 95 percent,
non-condensing.
Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards.
Make sure that the switch receives adequate ventilation. Do
not block the ventilation holes on each side of the switch
The power outlet should be within 1.8 meters of the switch.
13
Page 14
EX32905/EX32914 series www.etherwan.com

DIN Rail Mounting

Installation: Place the switch on the DIN rail from above using the slot. Push the front of the switch toward the mounting surface until it audibly snaps into place.
Removal: Pull out the lower edge and then remove the switch from the DIN rail.
14
Page 15
EX32905/EX32914 series www.etherwan.com

Connecting to Power

DC Terminal Block Power Inputs

Step 1: Connect the DC power cord to the plug-able terminal block on the
Step 2: Disconnect the power cord if you want to shut down the switch.
switch, and then plug it into a standard DC outlet.
The Terminal Block PWR Power Input GND Power Ground
Earth Ground
CAUTION: This equipment is designed to permit the connection of the earthed conductor of the DC supply circuit to the earthing conductor at the equipment.
If this connection is made, all of the following conditions must be met:
This equipment shall be connected to directly to the DC
supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode conductor is connected.
This equipment shall be located in the same immediate area
(such as, adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor, and also the point of
15
Page 16
EX32905/EX32914 series www.etherwan.com
earthing of the DC system. The DC system shall not be earthed elsewhere.
The DC supply source is to be located within the same
premises as the equipment.
Switching or disconnecting devices shall not be in the earthed
circuit conductor between the DC source and the point of connection of the earthing electrode conductor.
16
Page 17
EX32905/EX32914 series www.etherwan.com

Connecting to Your Network

Cable Type & Length

It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements.
Cable Specifications
Speed Connector Port Speed
Half/Full Duplex
10Base-T RJ-45 10/20 Mbps 2-pair UTP/STP
100Base-TX RJ-45 100/200 Mbps 2-pair UTP/STP
1000Base-T RJ-45 2000 Mbps 4-pair UTP/STP
1000Base-SX SC, ST 2000 Mbps MMF (50 or
1000Base-SX SC 2000 Mbps MMF (50 or
1000Base-LX SC 2000 Mbps SMF (9 or
1000Base-BX SC 2000 Mbps SMF (9 or
Cable Max.
Distance
100 m
Cat. 3, 4, 5
100 m
Cat. 5
100 m
Cat. 5
550 m
62.5μm)
2 km
62.5μm)
10 or 20 km
10μm)
20 km
10μm)
17
Page 18
EX32905/EX32914 series www.etherwan.com

Cabling

Step 1: First, ensure the power of the switch and end devices are turned off.
<Note> Always ensure that the power is off before any installation.
Step 2: Prepare cable with corresponding connectors for each type of port
<Note> To connect two regular RJ-45 ports between switches or hubs, you need a
Step 3: Consult the previous section for cabling requirements based on
Step 4: Connect one end of the cable to the switch and the other end to a
Step 5: Once the connections between two end devices are made
in use.
straight or cross-over cable.
connectors and speed.
desired device.
successfully, turn on the power and the switch is operational.
18
Page 19
EX32905/EX32914 series www.etherwan.com

Specifications

Industrial Compact Switch
Applicable Standards IEEE 802.3 10Base-T
Forwarding Rate 10Base-T: 100Base-TX: 1000Base-T/SX/LX/BX:
Performance 148,80pps for 10Mbps
Cable 10Base-T: 100Base-TX: 1000Base-T:
100Base-SX/LX/BX: LED Indicators Per unit – Power status (PWR)
Dimensions 30mm (W) × 82mm (D) × 114mm (H)
Net Weight 0.34Kg (0.75lb.) Power Terminal Block: 12-48VDC Operating Voltage &
Max. Current Consumption
Power Consumption 6.5W Max. Operating Temperature -10°C to 60°C (14°F to 140°F)
Storage Temperature -25°C to 85°C (-13°F to 185°F) Humidity 5%-95% non-condensing EMI FCC Part 15 Class A, VCCI
10/100/1000Base-TX auto-negotiating ports with RJ-45 connectors, 1000Base-SX/LX/BX fiber port
IEEE 802.3u 100Base-TX IEEE 802.3ab 1000Base-T IEEE 802.3z 1000Base-SX/LX
10 / 20Mbps half / full-duplex 100 / 200Mbps half / full-duplex 2000Mbps full-duplex
148,810pps for 100Mbps 1,488,100pps for 1000Mbps
2-pair UTP/STP Cat. 3, 4, 5 2-pair UTP/STP Cat. 5 4-pair UTP/STP Cat. 5 Up to 100m (328ft) MMF (50 or 62.5μm), SMF (9 or10μm)
Per port – 10/100/1000TX: 10/100, 1000 1000SX/LX/BX: 1000
(1.18” (W) × 3.23” (D) × 4.49” (H))
0.25A @ 24VDC
Tested for functional operation @
-20°C to 70°C (-4°F to 158°F)
EN61000-6-4: EN55022, EN61000-3-2, EN61000-3-3
19
Page 20
EX32905/EX32914 series www.etherwan.com
EMS EN61000-6-2:
Environmental Test Compliance
EN61000-4-2 (ESD Standard) EN61000-4-3 (Radiated RFI Standards) EN61000-4-4 (Burst Standards) EN61000-4-5 (Surge Standards) EN61000-4-6 (Induced RFI Standards) EN61000-4-8 (Magnetic Field Standards)
IEC60068-2-6 Fc (Vibration Resistance) IEC60068-2-27 Ea (Shock) FED STD 101C Method 5007.1 (Free Fall w/ package)
20
Loading...