EtherWAN EL1033 Quick Start Manual

Industrial PoE Media Converter
1
Quick Start Guide
This quick start guide describes how to install and use the Industrial PoE Media Converter. This is the Media Converter of choice for harsh environments constrained by space.
Physical Description
The Terminal Block and Power inputs
Power Input Assignment
48VDC
Power 1
Power Ground
Earth Ground
Terminal Block
Power 2 48VDC DC Jack
DC Terminal Block Power Inputs: There are two power inputs that can be used to power up this Industrial PoE Media
Industrial PoE Media Converter
2
Converter. Redundant power supplies function is supported.
The DIP Switch
DIP Switch
On Off
1 Enable forced mode for TX port Enable auto negotiation for TX port 2 TX port forced to 10Mbps TX port forced to 100Mbps 3 TX port forced to half duplex mode TX port forced to full duplex mode 4 Enable Link-Fault-Pass-Through Disable Link-Fault-Pass-Through
The 10/100Base-TX and 100Base-FX Connectors
1. The 10/100Base-TX Connections
The following lists the pinouts of 10/100Base-TX ports.
Pin Regular Ports Uplink port
1 Input Receive Data + Output Transmit Data + 2 Input Receive Data - Output Transmit Data ­3 Output Transmit Data + Input Receive Data + 4 NC NC 5 NC NC 6 Output Transmit Data - Input Receive Data ­7 NC NC 8 NC NC
2. The 100Base-FX Connections
The fiber port pinouts: The Tx (transmit) port of device I is connected to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II.
Industrial PoE Media Converter
3
3. The WDM 100Base-FX Connections
The fiber port pinouts: Only one single-mode optical fiber is required to transmit and receive data.
The Port Status LEDs
Industrial PoE Media Converter
4
LED State Indication
Power over Ethernet (PoE)
Steady Power Sourcing Equipment (PSE) is connected.
PD Power
Off Power Sourcing Equipment (PSE) is disconnected.
10/100Base-TX, 100Base-FX
Steady A valid network connection established.
Link/ACT
Flashing
Transmitting or receiving data. ACT stands for ACTIVITY.
DIN-Rail Kits, Optional Wall Mounting Kits
Functional Description
Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity for industrial environment.
Supports IEEE802.3af Power over Ethernet (PoE) Power Device (PD).
DIP Switch configuration for “Link-Fault-Pas-Through”, speed, duplex mode.
Industrial PoE Media Converter
5
Supports IEEE802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, Full/Half-duplex, Auto-Negotiation, Auto MDI/MDIX.
100Base-FX: Multi/Single mode SC or ST type, WDM Single mode SC type.
Supports 1024 MAC addresses. Provides 2.25M bits buffer memory.
Power Supplies: Redundant 48VDC Terminal Block power input and 48VDC DC JACK with 100-240VAC external power supply. “For use with Model AS-120P-48 as power jack supply source by MEAN WELL Enterprises Co., Ltd.".
Operating voltage and Max. current consumption:
0.075A @ 48VDC. Power consumption: 3.6W Max.
-10 to 60 ( 14℉ to 140) operating temperature range.
Supports DIN-Rail, Panel, or Wall Mounting installation.
Assembly, Startup, and Dismantling
Assembly: Place the Media Converter on the DIN rail from above using the slot. Push the front of the Media Converter toward the mounting surface until it audibly snaps into place.
Startup: Connect the supply voltage to start up the Media Converter via the terminal block (or DC JACK).
Dismantling: Pull out the lower edge and then remove the Media Converter from the DIN rail.
Industrial PoE Media Converter
6