EtherWAN EL100 User Manual

Media Converter
User’s Manual 1
Preface
This manual describes how to install and use the Ethernet Media Converter with the link-fault-pass-through function. The Converter introduced here provides one channel media conversion between 10/100Base-TX and 100Base-FX.
The Converter fully complies with IEEE802.3 10Base-T and IEEE802.3u 100Base-TX/FX standards.
In this manual, you will find:
y Product overview y Features on the media converter y Illustrative LED functions y Installation instructions y Specifications
Media Converter
2 User’s Manual
Table of Contents
PREFACE ................................................................................................................... 1
TABLE OF CONTENT S ............................................................................................... 2
INTRODUCTION ......................................................................................................... 3
PRODUCT OVERVIEW ............................................................................. 3
PRODUCT FEATURES ............................................................................. 3
PACKING LIST ........................................................................................ 4
ONE-CHANNEL MEDIA CONVERTER........................................................................ 5
PORTS ................................................................................................... 5
PORT SETTINGS ..................................................................................... 5
FRONT PANE L & LEDS .......................................................................... 6
LINK-FAULT -PASS -THROUGH ................................................................. 6
INSTALLATION.......................................................................................................... 8
SELECTING A SITE FOR THE EQUIPMENT ................................................. 8
CONNECTING TO POWER ........................................................................ 8
INSTALLING IN A CHASSIS ...................................................................... 8
SPECIFICATIONS ....................................................................................................... 9
Media Converter
User’s Manual 3
Introduction
The media converter provides one channel for media conversion between 10/100Base-TX and 100Base-FX. It can be used as a stand alone device or with a standard 19” chassis as shown below.
Product Overview
<NOTE> The chassis is to be ordered separately.
Product Features
y One-channel media conversion between 10/100Base-TX and 100Base-FX y Fiber media allows:
Multi-mode fiber using SC, ST, VF-45, MT-RJ or LC connector
Single-mode fiber using SC or ST connector
WDM single-fiber (bi-direction) transceiver: Single-mode WDM fiber using SC connector:
A type: WDM single-fiber (bi-direction) transceiver transmits with 1310nm wavelength and receives with 1550nm wavelength B type: WDM single-fiber (bi-direction) transceiver transmits with 1550nm wavelength and receives with 1310nm wavelength
y Auto negotiation of speed and duplex mode on TX port y Auto MDIX on TX port y One DIP switch for configuring link-fault-pass-through, fixed speed, and half/full duplex y 2048 MAC addresses, 768K bits buffer memory y Store-and-forward mechanism y Non-blocking full wire-speed forwarding rate y Support broadcast storm filtering y Back-pressure & IEEE802.3x compliant flow control y Front panel status LEDs y External AC to DC power adapter y Used as a stand-alone device or with a chassis y Hot-swappable when used with a chassis
Media Converter
4 User’s Manual
Packing List
When you unpack this product package, you will find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to our authorized reseller.
y The Media Converter y User’s Manual y AC to DC Power Adaptor
Media Converter
User’s Manual 5
One-Channel Media Converter
Ports
The Converter provides one TX port and one FX port. For the FX port, it provides options of Multi-mode fiber using SC, ST, VF-45, MT-RJ or LC connector or Single-mode fiber using SC or ST connector or WDM fiber using single SC connector For the TX port, it uses RJ-45 connector and auto senses the speed of 10/100Mbps.
Port Settings
Port settings are made very simple by means of a DIP (Dual Inline Package) switch at the rear panel of the module.
1 2 3 4 5 6
DIP switch
There are six pins on the DIP switch for port settings. Refer to the table below for more details.
DIP switch No.
Down (Default Setting) Up
1 Enable LFPT Disable LFPT LFPT:
link-fault-pass-
through 2 Enable auto negotiation for TX port Enable forced mode for TX port 3 TX port forced to 100Mbps TX port forced to 10Mbps 4 TX port forced to full duplex mode TX port forced to half duplex mode 5 FX port forced to full duplex mode FX port forced to half duplex mode 6
y First, disconnect the converter from the power. Then toggle Pin 2 of the DIP switch to the up position to enable the forced mode for TX port.
<NOTE> Pin 2 must be toggled up prior to speed and duplex mode settings
manually.
y Toggle down Pin 3 to force the TX port at the speed of 100Mbps. Or toggle up Pin 3 for 10Mbps speed.
y Toggle down Pin 4 to force the TX port at full duplex mode. Or toggle up Pin 4 for half duplex mode.
y Toggle down Pin 5 to force the FX port at full duplex mode. Or toggle up Pin 5 for half duplex mode.
y Toggle up Pin 1 to disable the link-fault-pass-through.
y Connect the converter to the power again. The new setting will come into effect then.
Media Converter
6 User’s Manual
Front Panel & LEDs
LED Indicators
The LED indicators give you instant feedback on status of the converter:
LEDs State Indication
Steady Power on
PWR stands for POWER
PWR
Off Power off Steady Connection at the speed of 100Mbps 100 (Mbps) Off Connection at the speed of 10Mbps Steady A valid network connection established
LNK stands for LINK
Flashing Transmitting or receiving data
ACT stands for ACTIVITY
LNK/ACT
Off Neither valid network connection established
nor transmitting/receiving data.
Steady Connection in full duplex mode
FDX stands for FULL-DUPLEX
Flashing Collision occurred
COL stands for COLLISION
FDX/COL
Off Connection in half-duplex mode
Link-Fault-Pass-Through
Connect the FX ports of two Media Converter A and B through the fiber cable.
1. Link Fault of the FX port: A Link Fault condition will be sensed on the TX port whenever the media converter detects a Link Fault condition on the FX port. Thus, the 100, LNK/ACT, and FDX/COL LEDs of the media converter would be off.
2. Link Fault of the TX port of the Media Converter A: The Media Converter A: A Link Fault condition will be sensed on the FX port whenever the media converter detects a Link Fault condition on the TX port. Thus, the 100, LNK/ACT, and FDX/COL LEDs of the TX port of the Media Converter A would be off. The Media Converter B: A Link Fault condition will be informed to the FX port of the Media Converter B. Then a Link Fault condition will be sensed on the TX port of the Media Converter B whenever the Media Converter B detects a Link Fault condition on the FX port. Thus, the 100, LNK/ACT, and FDX/COL LEDs of the Media Converter B would be off.
Media Converter
User’s Manual 7
Link Fault of the FX port TX Port FX Port LEDs PWR 100 LNK/ACT FDX/COL LNK/ACT FDX/COL Media Converter A
ON OFF OFF OFF OFF OFF
Media Converter B
ON OFF OFF OFF OFF OFF
Link Fault of the TX port of the Media Converter A TX Port FX Port LEDs PWR 100 LNK/ACT FDX/COL LNK/ACT FDX/COL Media Converter A
ON OFF OFF OFF ON ON
Media Converter B
ON OFF OFF OFF OFF OFF
Media Converter
8 User’s Manual
Installation
This chapter gives step-by-step installation instructions for the Converter.
Selecting a Site for the Equipment
As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
z The ambient temperature should be between 32 and 113 degrees Fahrenheit (0 to 45 degrees
Celsius).
z The relative humidity should be less than 95 percent, non-condensing. z Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for
IEC 801-3, Level 2 (3V/M) field strength.
z Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes
on each side of the equipment.
z The power outlet should be within 1.8 meters of the product.
Connecting to Power
y This Converter is a plug-and-play device.
y Connect the supplied AC to DC power adaptor to the receptacle on the rear panel of the converter,
and then attach the plug into a standard AC outlet.
Installing in a Chassis
The Converter can be fit into any of the expansion slots on a special designed chassis.
y First, install the converter onto a carrier supplied with the chassis: Step 1- Unscrew the carrier from the desired expansion slot on the chassis. Step 2- Fit the converter onto the carrier.
y When the converter is completely seated onto the carrier, insert the carrier to the guide rails of the expansion slot.
y Carefully slide in the carrier until it is fully and firmly fit the chassis. Fasten the screws onto the carrier.
<NOTE> Never insert any converter into the chassis directly without using the
supplied carriers. The carriers allow secure and consistent placement of the converters into the chassis’ backplane without causing any damage.
Media Converter
User’s Manual 9
Specifications
Applicable Standards IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX & 100Base-FX
Fixed Ports 1 TX port, 1 FX port
10/20Mbps for half/full-duplex 10Base-T speed
100Base-TX/FX speed
100/200Mbps for half/full-duplex
Switching Method Store-and-Forward
Forwarding rate 14,880/148,810pps for 10/100Mbps
Per Unit- (2 LEDs): Power; 100(Mbps) LED Indicators
Per Port- (2 LEDs): LNK/ACT; FDX/COL
Dimensions 80.3mm (W) × 109.2mm (D) × 23.8mm (H)
(3.16” (W) × 4.30” (D) × 0.94” (H)) Weight 150g (0.33lb.) Power External power adaptor 0.16A @ 12VDC Power Consumption 1.92W Max. Operating Temperature
0 ~ 45 (32 ~ 113) Storage Temperature
-10 ~ 70 (14 ~ 158)
Humidity 5 ~ 95%, non-condensing Safety UL60950-1 Emissions FCC Part 15 Class A, CE Mark Class A
Loading...