ETG LDO AC 3.0 Installation And Operation Manual

Material No.27120424
Installation and operation manual
for
Please read this operation manual before starting installation and start-up, make sure you understood the contents and pass the manual to others, if necessary. It provides instructions related to your safety and helps to avoid damage to the door drive
.
10/2015 Page 2 of 24
Contents Page
Safety regulations
Foreword
1 Definition of use 6
1.1 Intended use 6
1.2 Unacceptable use 6
1.3 Obligations of the installation company 6
1.4 Expansions and amendments 6 2 Technical description 7
2.1 System description 7
2.2 Functions 7
2.3 Operation elements and terminal layout on the board 9 3 Technical Data 10 4 Assembly and installation 11
5. Configuration 15 6 Error messages 19
10/2015 Page 3 of 24
Safety regulations
Scope of application and instructions
This operation manual is intended for all individuals who take part in installation and start-up of door drive LDO AC 3.0. Instructions contained in the operation manual must be strictly followed.
Other effective regulations
In addition to this operation manual, the following regulations must be adhered to:
- Accident prevention regulations
VBG 1 General regulations,
VBG 4 Electrical installation and tools,
ZH 1/228 Safety regulations for use of eletrical tools in conditions of serious
electrical hazard.
- Acts, regulations, safety regulations of national and international safety authorities, such as:
DIN VDE 0100 Construction of high voltage installations with rated voltage up to 1000 V
DIN VDE 0105 Operation of high voltage installations
DIN VDE 0106 Protection against electric currents hazardous for human body
Use of work equipment directive (EC Directive - 89/655/EEC)
Operational instructions, unless they render safety regulations of this operation manual
ineffective.
Personnel assignment and competences
All operations described in this manual must be performed under guidance and supervision of a qualified
technician. A qualified technician is an individual who is able to perform or to supervise performance of all operations on the door drive, in a professional manner.
In addition, the qualified technicians must:
be of at least 18 years of age and provide a professional certificate of preventive medical examination G 20,
obtain authorisation before the start of installation works of the entire installation of the elevator,
read the operation manual thoroughly and understand its contents,
is, in particular, instructed in the area of door drive technology and their cooperation with the
entire elevator installation as well as their functional routines.
has adequate knowledge of the entire elevator installation as well as of its cooperation with individual assemblies.
can prove adequate knowledge of regulations trlated to safety at workplace and accident prevention, as well as of relevant technical rules and regulations.
The technicial should perform and supervise only operations describen in this operation manual.
All further operations which may be performed on the door drive LDO AC 3.0, should be performed only by employees of Elevator Trading GmbH.
10/2015 Page 4 of 24
Accident prevention
Every individual knowing and following accident prevention regulations helps with preventing accidents from happening! Precautionary measures against recognizable accident hazards may enable to avoid heavy damage. Every employee is obliged to prevent accidents and occupational diseases from happening to the best of their ability. Recognized accident hazards must be immediately eliminated. If this is impossible, the hazardous areas must be secured, and the recognized accident hazard must be immediately reported to the supervisors.
Occupational safety
The operators have the following obligations related to ensuring occupational safety:
to remember to follow the UVV and other regulations related to occupational safety as well as proactively prevent accidents,
operation of accident preventing installations and devices as well as operational safety of the installation must be controlled in regular, defined intervals,
dangerous parts of the installation must be immediately removed from operation and seized using adequate protective measures,
deficient assemblies and installation parts as well as UVV violations must be immediately reported to the superiors,
in case of works being performed on tools and equipment under voltage, their power supply must be switched off beforehand.
Behaviour in case of an accident at work
In case of an accident at work resulting in serious consequences, provide first aid and immediately inform emergency services (emergency doctor) about the accident. The company management must be immediately informed about every such accident. An accident report must be prepared.
Visitors
Visitors are forbidden to enter and be present in the installation works area for the entire elevator installation.
Safety markings
The following safety markings according to VBG 125 have been used on parts of the door drive as well as in the operation manual.
Warning against hazardous voltage
Switch off the power supply before
work
Warning against automatic operation
10/2015 Page 5 of 24
Foreword
This operation manual describes the door drive for personal and cargo elevators LDO AC 3.0 according to EN81. The operation manual is divided into chapters. In Chapter 1, the intended use of the door drive is defined in a form of a use description. In Chapter 2, technical description of the door drive is provided, ensuring a good overview of its design and operation. In addition, operating elements and indicators are explained. The most important technical data can be found in Chapter 3. Chapter 4 describes the operations required to perform the installation and assembly. Configuration of the door drive is described in Chapter 5.
Because of necessity of keeping the operation manual a summarizing one, not all d
etailed
information related to every possible implementation and design of the door drive LDO AC 3.0 and note every possible and imaginable configuration, operation or maintenance work could have been included. Should you require further information or if particular problems occur, the required information can be obtained by contacting Elevator Trading GmbH.
Elevator Trading GmbH indicates that the contents of this operation manual is not one of and
should not change previous or existing agreements, promises or other legal relationships. All obligations of Elevator Trading GmbH result from every respective sales contract, which also includes complete and independendly effective warranty rules. These contractual warranty regulations are neither expanded nor limited by the implementation of this operation manual.
Elevator Trading GmbH is continously working on further development of its products. It must
be understood that in case of diagrams and technical data, related to the design, equipment and know-how knowledge, technical modifications are possible in the future, corresponding
to new developments. Particular emphasis was placed on user-friendly structure of the operation manual, ensured thanks to demonstrative and descriptive figures and textual information. References to figures are provided in the text using brackets. In the references, the first numbers before the dash indicate the chapter and figure number, and the second number, if any, located after the dash, indicates a reference number on the respective figure. For example:
(Figure 3
-
2) means figure 2 in Chapter 3.
Important information for operators and maintenance personnel is marked with pictorgrams.
They mark important information that the installation and maintenance personnel mus
t pay
particular attention to.
They mark work and operation methods that must be strictly followed in order to avoid damage or destruction of the door drive and of the entire elevator installation.
They mark work and operation methods that must be strictly followed in order to exclude hazard to people.
10/2015 Page 6 of 24
1 Definition of use
1.1 Intended use
The door drive LDO AC 3.0 manufactured by Eleveator Trading GmbH described in this operation manual is used as a control measure and as a drive of doors in electrically driven elevators as understood according to EN 81. This operation manual describes in detail how and under observance of which regulations and conditions the door drive should be installed and operated.
Only use described in the EN81 standard should be understood as intended use. Every
other use is considered unintended and is forbidden.
1.2 Unacceptable use
Every use of the door drive which is not included in uses described in this operation manual and in the EN 81 standard is considered unacceptable. This refers in particular to not observing or exceeding the limits and characteristc values provided in Chapter 3 "Technical Data". Elevator Trading GmbH shall not be held responsible for damage which results from violation of prohibitions laid out in this operation manual.
1.3 Obligations of the installation company
The installation company that performs complete assembly and installation of an elevator installation ready for operation, performs its start-up and maintenance, bears the responsibility for the door drive to be used as understood in this operation manual and in the EN 81 standard. The installation company shall implement the entire operation manual of the door drive LDO AC 3.0 in the operation manual and operation instructions of the entire elevator installation, without changing or rendering a single point ineffective.
1.4 Expansions and amendments
Should the use and environment of the door drive change in such a manner that its funcion or specified limits and characteristing values can no longer correspond to regulations set forth i this operation manual, Elevator Trading GmbH should undertake appropriate adaptations and customizations. In addition, a permission of the local agencies may be required. Unauthorized modifications and expansions of the the door drive may have inadvertent and diminishing effect on the safety, so the declaration of the manufacturer expires.
10/2015 Page 7 of 24
2 Technical description
2.1 System description
The door drive LDO AC 3.0 is an "intelligent" door drive. Thanks to this drive, the elevator door may be opening and closing with regulated speeds and accelerations. The maintenance-free door drive comprises of a control system which is installed inside a housing, and of a drive in the form of a gear motor. It uses a standard, alternating current, asynchronous motor with a non-self-locking gear. Toothed belts are used to transfer the driving force. The drive system can be used for operating a one-sidedly and centrally-opening doors. The driving motor can be manufactured with differently installed toothed belt pulleys, for doors opened to the right and to the left. The door drive does not require an end switch. The door widith and the "open" and "closed" positions are determined automatically. The door status can be transmitted over to the master elevator control using relay contacts.
2.2 Functions
Door width determination
Door width determination must be triggered as an automatic process within the framework of assembly and installation. This operation is described in Chapter „4 Assembly and installation“ .
The Door openingcommand The "Door opening" command causes the door to open according to the predetermined motion curve, as long as the command is present. The "Door opening" command must be present during the entire opening motion.
The Door closingcommand The "Door closing" command causes the door to close according to the predetermined motion curve, as long as the command is present. The "Door closing" command must be present during the entire closing motion.
The first closing motion after a power outage takes place at slow speed. Only if the door commands last a longer time, the door motor remains in the end positions under an acting moment. When no holding moment exists in the "Door closed" position (the command "Door closing" is
not present), the door
closes automatically, when it has been opened for more than 3 increments.
Interruption and reversal of the closing motion
There are three different events that lead to interruption and reversal of the closing motion:
A light barrier attached directly to the door drive signals an interruption of the light ray.
The door encounters an obstacle during its closing motion.
The door becomes blocked already in the "open" position.
If any of these three events is detected, the motion taking place shal be briefly interrupted. This interruption shall be repeated two times and then the door moves to the "Door open" position and waits 10 seconds. Next, the still present closing command is executed as normal, and the door closes in the usual manner again. In case of an interruption of the closing command, the pause ends up immediately.
10/2015 Page 8 of 24
The Pushcommand
In the operational state of pushing, the state of the light barrier attached directly to the door drive is not observed and the closing speed is lowered. The commands „Push“ and „Door closing“ must be present simultaneously.
Emergency release
If the door is closed, the emergency release is possible under following conditions:
when the door is in a standstill,
no commands from the elevator control system exist, and
no service button of the door drive was pressed.
When the door was determined to be open byb more than 20 increments (more than 14 mm) from the "Door closed position", the door recognizes this as emergency release and disconnects the automatic "Door closing" command.
The force required to open the door is smaller than 300 N.
Light barrier
A voltage ranging from 18 to 27V DC at the light barrier input is interpreted as interruption of the light ray of the light barrier. This voltage is measured against 24 V GND. In case of closing door, interruption of the light barrier results in the closing motion being interrutped and as long as a light barrier command is present, a slow, opening motion is executed.
Loading...
+ 16 hidden pages