Eternity Plus M20, JSW52-26VH, M26-50, JSW52-26VH-50, JSW40-20VH-50 Installation Manual

...
WaterMark
GMK10177
WMKA22451
Thank you very much for purchasing our water heater. Before installing and operating your water heater, please read this manual carefully and keep it for future reference.
FOR EXTERNAL INSTALLATION ONLY
Eternity Plus
GAS WATER HEATERS
MODELS M20 (JSW40-20VH) M20-50 (JSW40-20VH-50) M26 (JSW52-26VH) M26-50 (JSW52-26VH-50)
1
CONTENTS
PAGE
1. IMPORTANT NOTES .........................................................................................................................2
1.1. INSTALLATION NOTES........................................................................................................2
1.2. SERVICE NOTES .................................................................................................................2
1.3. PLUMBING NOTES ..............................................................................................................2
2. SPECIFICATION ................................................................................................................................4
3. INTRODUCTION................................................................................................................................5
3.1. DIMENSIONS AND CONNECTION POINTS (M20) .............................................................6
3.2. DIMENSIONS AND CONNECTION POINTS (M26) .............................................................7
3.3. SAFETY GUIDELINES..........................................................................................................8
3.4. GENERAL GUIDELINES.......................................................................................................8
4. INSTALLATION..................................................................................................................................9
4.1. CONFIRM THE APPLIANCE SUITABILITY .........................................................................9
4.2. SELECTING A SUITABLE LOCATION FOR INSTALLATION ...............................................10
4.3. CLEARANCES FOR OUTDOOR HEATER LOCATIONS ....................................................11
4.4. GAS CONNECTION..............................................................................................................12
4.5. SIZING AND CONNECTION SUITABILITY ..........................................................................12
4.6. MEASURING INLET GAS PRESSURE AND TESTING GAS LEAKAGE.............................13
4.7. WATER CONNECTIONS ......................................................................................................14
4.8. ELECTRICAL CONNECTIONS.............................................................................................14
5. REMOTE CONTROLLER ..................................................................................................................15
5.1. REMOTE CONTROLLER INSTALLATION ...........................................................................16
5.2. CONNECTION OF REMOTE CONTROLLER WIRING TO THE WATER HEATER.............17
6. INITIAL OPERATION.........................................................................................................................18
7. NORMAL OPERATION......................................................................................................................19
7.1. NORMAL OPERATION WITHOUT REMOTE CONTROLLER..............................................19
7.2. NORMAL OPERATION WITH MULTIPLE REMOTE CONTROLLERS INSTALLED............19
7.3. FREEZE PREVENTION........................................................................................................19
8. MAINTENANCE AND SERVICE........................................................................................................20
8.1. UNIT DRAINING AND FILTER CLEANING...........................................................................20
8.2. GENERAL TROUBLESHOOTING ........................................................................................21
8.3. PCB ERROR CODES ...........................................................................................................22
8.4. WIRING DIAGRAM ...............................................................................................................23
8.5. WATER FLOW AND WATER TEMPERATURE (M20) ..........................................................24
8.6. WATER FLOW AND WATER TEMPERATURE (M26) ..........................................................24
9. WARRANTY CONDITIONS ...............................................................................................................25
2
WARNING
1.1 INSTALLATION NOTES
1.2 SERVICE NOTES
1.3 PLUMBING NOTES
The installation must be done in accordance with the information supplied in this manual. All other relevant national, state and local regulations must also be adhered to including (but are not limited to):
Australian Standard AS3500.1 – Water Services. Australian Standard AS3500.4 – Heated Water Services. Australian Standard AS3000 – Electrical Installation. Australian Standard AS/NZS5601 – Gas Appliance Installation. Local Water, Gas & Electrical Authority Regulations. Municipal Building Codes including local OH&S requirements.
Installation and service must be performed by a licensed professional (for example, a licensed plumber or gas fitter).
Water pipe size is nominal 15mm from hot water outlet to the first tap / outlet.
Gas pipe size is nominal 20mm.
!
When connecting the hot water supply to the fixtures of the property a minimum of two (2) metres of pipework must be used between the outlet of the water heater and the first tap / outlet. (See Diagram on following page).
The hot water line should be insulated with Armaflex or similar pipe insulation.
When the installation is completed the temperature is to be tested at the taps to confirm the water temperature does not exceed the required 50 setting.
1. IMPORTANT NOTES
This manual has been prepared for the relevant licensed professionals of the equipment. Please keep it in a safe place for future reference.
Maintenance and fault-finding must be done in accordance with these instructions and the applicable regulations listed above.
PLEASE NOTE M20-70°C model is supplied factory pre-set at Nominal 70°C maximum outlet water temperature to comply with the requirements of AS 3498 Clause 7.2.2.
PLEASE NOTE M20-50°C model is supplied factory pre-set at Nominal 50°C maximum outlet water temperature to comply with the requirements of AS 3498 Clause 7.2.1.
The M20-70°C unit REQUIRES a temperature control device to be installed.
The M20-50°C unit DOES NOT REQUIRE a temperature control device to be installed.
Please follow all the instructions in the Installation Guide and the following additional instructions for the water heater outlet connection.
3
HOT
WATER
OUTLET
COLD
WATER
INLET
GAS INLET
ENSUITE
LAUNDRY
BATHROOM
KITCHEN
CONTROLLER 1
(OPTIONAL)
CONTROLLER 2
(OPTIONAL)
CONTROLLER 3
(OPTIONAL)
MIN. 2 METRES
(FROM HOT OUTLET TO NEAREST HOT WATER TAP/OUTLET)
50ºC PRESET UNIT
HOT
WATER
OUTLET
COLD
WATER
INLET
GAS INLET
ENSUITE
LAUNDRY
BATHROOM
KITCHEN
CONTROLLER 1
(OPTIONAL)
CONTROLLER 2
(OPTIONAL)
CONTROLLER 3
(OPTIONAL)
MIN. 2 METRES
(FROM HOT OUTLET TO NEAREST HOT WATER TAP/OUTLET)
70ºC PRESET UNIT
(NOTE: TCD - TEMPERATURE CONTROL DEVICE)
NOTE: M20 UNIT SHOWN IN ABOVE EXAMPLES
TCD
4
Gas Type
MODEL
Natural
Gas
Propane
(LPG)
Natural
Gas
Propane
(LPG)
Gas InputMJ/h
160
Inlet PressurekPa
1.13 - 2.75 2.75 - 4.00
Main Injectormm
φ1.65 φ0.96
Test Point Pressure High/LowkPa
0.61/0.15 1.89/0.19
Water Heating Capacity (At 25ºC Rise
20L/min
Max. Water PressurekPa
1000
Min. Water Pressure kPa
150
Relief Valve Pressure SettingkPa
1200
Gas Connection
Water Connections
Ingress Protection RatingAS60529):
Ignition
Rated Voltage
Net WeightkG)
15.4
Gross WeightkG
16
Product Dimensionsmm
595 x 375 x 165
IAPMO Water Mark Approval Number
WMKA22451
IAPMO Gas Mark Approval Number
GMK10177
Package Dimensionsmm
748 x 420 x 230
200
M20 M26
1.13 - 2.75 2.75 - 4.00
φ1.70 φ1.10
0.76/0.15 1.51/0.16
26L/min
3/4” (Nom 20mm)
1/2” (Nom 15mm)
IPX4
Electronic
AC.240V/50Hz
19.2
21.5
628 x 413 x 177
735 x 455 x 267
2. SPECIFICATIONS
NOTES
The appliance will operate at reduced performance below 340 kPa water pressure.
For information relating to burner test point pressures and injector sizes refer to the name plate located on the right hand side of the case for each model. (please refer to p.9)
For information relating to overall dimensions and connection points refer to diagrams. (Please refer to p.6 & 7)
Installing in areas over 1500 m above sea level will reduce performance.
TECHNICAL DATA AND DIMENSIONS
5
Heat Exchanger
Thermistor
Computer
board
Hot Water
Outlet
Cold Water
Inlet
Gas Inlet
AC
240V
Flow
Sensor
Exhaust
Burner
Gas Valve
Fan
Fan
Computer board
Heat Exchanger
Thermistor
Gas Inlet
AC240V
Gas
Valve
Flow Sensor
Hot Water
Outlet
Cold Water
Inlet
Exhaust
Burner
This manual provides information necessary for the installation, operation, and maintenance of the water heater.
The model description is listed on the name plate which is attached to the right side of the case of the water heater. (Please refer to p.9)
Please read all installation instructions completely before installing this product.
The Water Heater is an instantaneous, water heater designed to efficiently supply endless hot water on demand.
The principle of the water heater is shown below:
3. INTRODUCTION
The diagrams are representative only and do not truly represent the physical product.
1. A hot water tap is turned on.
2. Water enters the water heater via the cold water inlet.
3. The water flow sensor detects the water flow.
4. The computer automatically ignites the burner.
5. Water circulates through the heat exchanger and is heated
6. The computer will modulate the gas supply valve and water flow to produce the right amount of hot water at the correct temperature.
7. When the tap is turned off, the unit shuts down.
M20 UNIT M26 UNIT
6
355
355
375
565
595
610
165
148
GAS INLET
3/4” (NOM 20mm)
PRESSURE RELIEF
VALVE & WATER
INLET FILTER
COLD WATER INLET
1/2” (NOM 15mm)
REMOTE
CONTROLLER
CABLE POINT
HOT WATER
OUTLET
1/2” (NOM 15mm)
3.1 DIMENSIONS AND CONNECTION POINTS (M20)
7
GAS INLET
3/4” (NOM 20mm)
PRESSURE RELIEF
VALVE & WATER
INLET FILTER
COLD WATER INLET
1/2” (NOM 15mm)
REMOTE
CONTROLLER
CABLE POINT
HOT WATER
OUTLET
1/2” (NOM 15mm)
3.2 DIMENSIONS AND CONNECTION POINTS (M26)
195
176
385
413
595
645
645
390
Loading...